Reduction Techniques of Partial Discharge, Dissipation Factor, and External Corona for High Voltage Stator Windings

被引:5
|
作者
Emery, F. T. [1 ]
机构
[1] Siemens Energy Inc, Charlotte, NC 28273 USA
关键词
D O I
10.1109/EIC.2009.5166364
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High voltage stator windings in modern electric generators are subject to high electrical, mechanical, and thermal stress. Operation of these machines in both air and high pressure hydrogen results in different considerations. Operation in the air environment doesn't offer the dielectric advantages of operating in high-pressure hydrogen. The two major design factors that are significant for the design of high voltage stator bars to be operated in air, are corona activity and PD activity. These of course are closely related. With the movement to increasing the power density of generators, which means operation at higher voltages and higher insulation stress levels, it has become more critical to be sure the design constraints are met in the stator bar design to minimize both partial discharge activity and corona activity involving the stator bars. The stator bar insulation system must be designed for minimum partial discharge activity and ideally is corona free at the stator winding operating stress levels, and at the operating conditions (temperature and pressure) the generator is subject to. This paper will present the findings associated with the development work in designing, testing and implementing a PD reduced and corona free design.
引用
收藏
页码:315 / 327
页数:13
相关论文
共 50 条
  • [1] Partial discharge, dissipation factor, and corona aspects for high voltage electric generator stator bars and windings
    Emery, FT
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 347 - 361
  • [2] Analysis of partial discharge to high voltage motor stator windings
    Kim, HD
    [J]. 2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 340 - 343
  • [3] Measurement and analysis of partial discharge in high voltage motor stator windings
    Kim, HD
    Ju, YH
    [J]. PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING TECHNOLOGY CONFERENCE, 2003, : 27 - 31
  • [4] Analysis of Transition Cause of Partial Discharge Patterns in High Voltage Motor Stator Windings
    Koo, Ja-Young
    Kwak, Jun-Ho
    Kim, Hee-Dong
    [J]. Transactions of the Korean Institute of Electrical Engineers, 2024, 73 (08): : 1456 - 1460
  • [5] Partial discharge patterns and the identification of defects in high voltage stator windings insulation.
    Kouadria, D
    Watt, G
    [J]. EIGHTH INTERNATIONAL CONFERENCE ON DIELECTRIC MATERIALS, MEASUREMENTS AND APPLICATIONS, 2000, (473): : 236 - 240
  • [6] Power Factor measurements on high voltage Stator bars & Stator windings
    Emery, FT
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 502 - 505
  • [7] DISCHARGE DETECTION TECHNIQUES FOR STATOR WINDINGS
    WILSON, A
    JACKSON, RJ
    WANG, N
    [J]. IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1985, 132 (05): : 234 - 244
  • [8] Dissipation Factor and Partial Discharge Measurements for the Quality Assessment of New Coils and Stator Windings of VPI Rotating Machines
    Contin, Alfredo
    Peruzzi, Gabriele
    [J]. 2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 455 - 458
  • [9] The Effect of Temperature on Slot Discharge for High Voltage Stator Windings
    Duan, Dingqiang
    Wang, Fei
    [J]. 3RD ASIAN PACIFIC CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (APEESD 2017), 2017, : 31 - 36
  • [10] Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings
    Kim, Hee-Dong
    Kong, Tae-Sik
    Lee, Sang-Kil
    Kim, Beom-Soo
    Kim, Doo-Young
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2015, 10 (03) : 1086 - 1092