APD-based PET detector for simultaneous PET/MR imaging

被引:63
|
作者
Grazioso, Ronald [1 ]
Zhang, Nan
Corbeil, James
Schmand, Matthias
Ladebeck, Ralf
Vester, Markus
Schnur, Guenter
Renz, Wolfgang
Fischer, Hubertus
机构
[1] Siemens Mol Imaging, Knoxville, TN USA
[2] Seimens AG Med Solut MR, Erlangen, Germany
关键词
avalanche photodiode; positron emission tomography; magnetic resonance;
D O I
10.1016/j.nima.2006.08.121
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two, APD-based, PET modules have been evaluated for use in combined PET/MR imaging. Each module consists of 4 independent, optically isolated detectors. Each detector consists of an 8 x 8 array of 2 x 2 x 20 mm LSO crystals read out by a 2 x 2 array of 5 x 5 mm Hamamatsu S8664-55 APDs. The average crystal energy resolution and time resolution (against a plastic scintillator on a PMT) of the detectors was 17% and 1.8 ns, respectively. The modules were positioned in the tunnel of a 1.5 T Siemens Symphony MR scanner. The presence of the PET modules decreased the M R signal-to-noise ratio by about 15% but no image interference was observed. The gradient and RE pulse sequences of the MR produced adverse effects on the PET event signals. These high-frequency pulses did not affect the true PET events but did increase the dead time of the PET system. Simultaneous, artifact-free, images were acquired with the PET and MR system using a small Derenzo phantom. These results show that APD-based PET detectors can be used for a high-resolution and cost-effective integrated PET/MR system. (c) 2006 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:301 / 305
页数:5
相关论文
共 50 条
  • [31] Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain
    Jung, Jin Ho
    Choi, Yong
    Jung, Jiwoong
    Kim, Sangsu
    Lim, Hyun Keong
    Im, Ki Chun
    Oh, Chang Hyun
    Park, Hyun-wook
    Kim, Kyung Min
    Kim, Jong Guk
    MEDICAL PHYSICS, 2015, 42 (05) : 2354 - 2363
  • [32] RF-Penetrable PET insert for simultaneous PET/MR imaging
    Brian J Lee
    Alexander M Grant
    Chen-Ming Chang
    Craig S Levin
    EJNMMI Physics, 1 (Suppl 1)
  • [33] Development of PET insert for simultaneous PET/MR imaging of human brain
    Jiwoong Jung
    Yong Choi
    Jin Ho Jung
    Sangsu Kim
    Ki Chun Im
    Hyun Keong Lim
    Changheun Oh
    HyunWook Park
    Gyuseong Cho
    EJNMMI Physics, 1 (Suppl 1)
  • [34] Quantitative Simultaneous PET-MR Imaging
    Ouyang, Jinsong
    Petibon, Yoann
    Huang, Chuan
    Reese, Timothy G.
    Kolnick, Aleksandra L.
    El Fakhri, Georges
    MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS VI, 2014, 9083
  • [35] Assessment of artifacts in simultaneous PET and MR imaging
    Slates, R
    Shao, Y
    Farahani, K
    Marsden, PK
    Cherry, SR
    Meadors, K
    Taylor, J
    Summers, PE
    Williams, S
    Beech, J
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1357 - 1360
  • [36] CONTINUOUS SCINTILLATOR DETECTOR BLOCKS FOR SIMULTANEOUS PET-MR IMAGING OF THE HUMAN BRAIN
    Rato Mendes, Pedro
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 121 - 127
  • [37] Signal to noise ratio of APD-based monolithic scintillator detectors for high resolution PET
    Maas, Marnix C.
    Schaart, Dennis R.
    van der Laan, D. J.
    van Dam, Herman T.
    Huizenga, Jan
    Brouwer, J. C.
    Bruyndonckx, Peter
    Lemaitre, Cedric
    van Eijk, Carel W. E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 842 - 852
  • [38] Automatic Channel Fault Detection on a Small Animal APD-Based Digital PET Scanner
    Charest, Jonathan
    Beaudoin, Jean-Franois
    Cadorette, Jules
    Lecomte, Roger
    Brunet, Charles-Antoine
    Fontaine, Rejean
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2494 - 2502
  • [39] LabPETtm:: A second-generation APD-based digital scanner for high-resolution small animal PET imaging
    Lecomte, R.
    deKemp, R. A.
    Klein, R.
    Cadorette, J.
    Lepage, M. D.
    Robert, G.
    Selivanov, V.
    Belanger, F.
    Semmaoui, H.
    Tetrault, M. A.
    Viscogliosi, N.
    Bergeron, M.
    Lemieux, F.
    Lemonde, M. A.
    Fontaine, R.
    MEDICAL PHYSICS, 2006, 33 (07) : 2671 - 2671
  • [40] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59