The Role of Titanium Implant Surface Modification with Hydroxyapatite Nanoparticles in Progressive Early Bone-Implant Fixation In Vivo

被引:0
|
作者
Lin, Audrey [1 ,2 ,3 ]
Wang, Chiachien Jake [1 ,2 ,3 ]
Kelly, James [1 ,2 ,3 ]
Gubbi, Prabhu [4 ]
Nishimura, Ichiro [1 ,2 ,3 ]
机构
[1] Univ Calif Los Angeles, Weintraub Ctr Reconstruct Biotechnol, Sch Dent, Div Adv Prosthodont, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Div Biomat, Sch Dent, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Div Hosp Dent, Sch Dent, Los Angeles, CA 90095 USA
[4] Biomet 3i, Palm Beach Gardens, FL USA
基金
美国国家卫生研究院;
关键词
crystalline hydroxyapatite; nanosurface topography; nanotechnology; osseointegration; titanium alloy; OSTEOBLAST ADHESION; CELL-ADHESION; INTEGRATION; ROUGHNESS; DIFFERENTIATION; NANOTOPOGRAPHY; CAPACITY; COATINGS; TI;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the biologic effect in vivo of hydroxyapatite (HA) nanoparticle surface modification on commercially pure titanium or titanium alloy (Ti-6Al-4V) implants. Materials and Methods: Miniature cylindric titanium and Ti-6Al-4V implants were pretreated with dual acid etching (DAE), and a subset was further modified with HA nanoparticles using discrete crystalline deposition (DCD). The resultant implant surface topography was characterized by interferometry and scanning electron microscopy. Miniature implants of DAE titanium, DAE Ti-6Al-4V, DCD titanium, and DCD Ti-6Al-4V were surgically placed in the femora of rats. After 4 days, 1 week, and 2 weeks of healing, osseointegration was evaluated by implant push-in tests or microcomputed tomography (microCT). Ti-6Al-4V samples were harvested at week 2 and prepared for nondecalcified histology and subjected to bone-to-implant contact (BIC) measurement, Results: DCD treatment generated a complex surface morphology via the bonded HA nanoparticles. However, the amplitude and spatial, hybrid, and functional surface roughness parameters measured at the micron and submicron levels did not depict topographic differences between the DAE and the DCD-modified implants. DAE titanium and DAE Ti-6Al-4V implants showed a sharp increase in push-in values at week 1, followed by a plateau at week 2. DCD titanium and DCD Ti-6Al-4V implants showed similar sharp increases at week 1, but the push-in values continued to increase at week 2. The surrounding bone architecture evaluated by microCT and the BIC ratio did not correlate with the biomechanical implant osseointegration measurement. Conclusions: DCD-derived surface modification with HA nanoparticles on titanium and Ti-6Al-4V implants resulted in progressive osseointegration profiles that were distinctively different from those of DAE controls Surrogate measurements such as surface roughness parameters and BIC did not predict the biologic effect of the DCD treatment. The data indicate that early osseointegration may be more sensitively regulated by nanoscale surface characteristics INT J ORAL MAXILLOFAC IMPLANTS 2009;24:808-816
引用
收藏
页码:808 / 816
页数:9
相关论文
共 50 条
  • [31] Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
    Walsh, William R.
    Bertollo, Nicky
    Christou, Chrisopher
    Schaffner, Dominik
    Mobbs, Ralph J.
    SPINE JOURNAL, 2015, 15 (05): : 1041 - 1049
  • [32] The Interaction of Osteoblasts With Bone-Implant Materials: 1. The Effect of Physicochemical Surface Properties of Implant Materials
    Kubies, D.
    Himmlova, L.
    Riedel, T.
    Chanova, E.
    Balik, K.
    Douderova, M.
    Bartova, J.
    Pesakova, V.
    PHYSIOLOGICAL RESEARCH, 2011, 60 (01) : 95 - 111
  • [33] Pedicle screws with a thin hydroxyapatite coating for improving fixation at the bone-implant interface in the osteoporotic spine: experimental study in a porcine model
    Ohe, Makoto
    Moridaira, Hiroshi
    Inami, Satoshi
    Takeuchi, Daisaku
    Nohara, Yutaka
    Taneichi, Hiroshi
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 28 (06) : 679 - 687
  • [34] PUTATIVE EARLY RISK FACTORS AT BONE-IMPLANT INTERFACE IN IMMEDIATE LOADING
    Iliescu, Alexandru-Andrei
    Iliescu, Radita
    Rusu, Darian
    Didilescu, Andreea Cristiana
    Tanase, Gabriela
    Iliescu, Andrei
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2009, 1 (01): : 25 - 33
  • [35] Effect of sintered silicate-substituted hydroxyapatite on remodelling processes at the bone-implant interface
    Porter, AE
    Patel, N
    Skepper, JN
    Best, SM
    Bonfield, W
    BIOMATERIALS, 2004, 25 (16) : 3303 - 3314
  • [36] The effect of plasma chemical oxidation of titanium alloy on bone-implant contact in rats
    Diefenbeck, Michael
    Mueckley, Thomas
    Schrader, Christian
    Schmidt, Jurgen
    Zankovych, Sergiy
    Bossert, Joerg
    Jandt, Klaus D.
    Faucon, Mathilde
    Finger, Ulrich
    BIOMATERIALS, 2011, 32 (32) : 8041 - 8047
  • [37] EFFECT OF SURFACE-ROUGHNESS ON ATTACHMENT STRENGTH OF BONE-IMPLANT INTERFACE
    YANAGISAWA, I
    SAIRENJI, E
    YANAGISAWA, S
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 231 - 231
  • [38] Surface modification of titanium implant and in vitro biocompatibility evaluation
    Zeng, Q
    Chen, ZQ
    Li, QL
    Li, G
    Darvell, BW
    ASBM6: ADVANCED BIOMATERIALS VI, 2005, 288-289 : 315 - 318
  • [39] Experimental study of bone response to hydroxyapatite coating implants: bone-implant contact and removal torque test
    Eom, Tae-Gwan
    Jeon, Gyeo-Rok
    Jeong, Chang-Mo
    Kim, Young-Kyun
    Kim, Su-Gwan
    Cho, In-Hee
    Cho, Yong-Seok
    Oh, Ji-Su
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (04): : 411 - 418
  • [40] Surface modification and wettability control of titanium dental implant
    Lin, Zeng
    Wang, Yong
    Wang, Feng
    Gao, Ding
    Li, Jianchang
    Ba, Dechun
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2012, 32 (11): : 939 - 973