The Role of Titanium Implant Surface Modification with Hydroxyapatite Nanoparticles in Progressive Early Bone-Implant Fixation In Vivo

被引:0
|
作者
Lin, Audrey [1 ,2 ,3 ]
Wang, Chiachien Jake [1 ,2 ,3 ]
Kelly, James [1 ,2 ,3 ]
Gubbi, Prabhu [4 ]
Nishimura, Ichiro [1 ,2 ,3 ]
机构
[1] Univ Calif Los Angeles, Weintraub Ctr Reconstruct Biotechnol, Sch Dent, Div Adv Prosthodont, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Div Biomat, Sch Dent, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Div Hosp Dent, Sch Dent, Los Angeles, CA 90095 USA
[4] Biomet 3i, Palm Beach Gardens, FL USA
基金
美国国家卫生研究院;
关键词
crystalline hydroxyapatite; nanosurface topography; nanotechnology; osseointegration; titanium alloy; OSTEOBLAST ADHESION; CELL-ADHESION; INTEGRATION; ROUGHNESS; DIFFERENTIATION; NANOTOPOGRAPHY; CAPACITY; COATINGS; TI;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the biologic effect in vivo of hydroxyapatite (HA) nanoparticle surface modification on commercially pure titanium or titanium alloy (Ti-6Al-4V) implants. Materials and Methods: Miniature cylindric titanium and Ti-6Al-4V implants were pretreated with dual acid etching (DAE), and a subset was further modified with HA nanoparticles using discrete crystalline deposition (DCD). The resultant implant surface topography was characterized by interferometry and scanning electron microscopy. Miniature implants of DAE titanium, DAE Ti-6Al-4V, DCD titanium, and DCD Ti-6Al-4V were surgically placed in the femora of rats. After 4 days, 1 week, and 2 weeks of healing, osseointegration was evaluated by implant push-in tests or microcomputed tomography (microCT). Ti-6Al-4V samples were harvested at week 2 and prepared for nondecalcified histology and subjected to bone-to-implant contact (BIC) measurement, Results: DCD treatment generated a complex surface morphology via the bonded HA nanoparticles. However, the amplitude and spatial, hybrid, and functional surface roughness parameters measured at the micron and submicron levels did not depict topographic differences between the DAE and the DCD-modified implants. DAE titanium and DAE Ti-6Al-4V implants showed a sharp increase in push-in values at week 1, followed by a plateau at week 2. DCD titanium and DCD Ti-6Al-4V implants showed similar sharp increases at week 1, but the push-in values continued to increase at week 2. The surrounding bone architecture evaluated by microCT and the BIC ratio did not correlate with the biomechanical implant osseointegration measurement. Conclusions: DCD-derived surface modification with HA nanoparticles on titanium and Ti-6Al-4V implants resulted in progressive osseointegration profiles that were distinctively different from those of DAE controls Surrogate measurements such as surface roughness parameters and BIC did not predict the biologic effect of the DCD treatment. The data indicate that early osseointegration may be more sensitively regulated by nanoscale surface characteristics INT J ORAL MAXILLOFAC IMPLANTS 2009;24:808-816
引用
收藏
页码:808 / 816
页数:9
相关论文
共 50 条
  • [41] In vivo monitoring of bone-implant bond strength by microCT and finite element modelling
    Stadelmann, Vincent A.
    Conway, Carl M.
    Boyd, Steven K.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (09) : 993 - 1001
  • [42] Surface modification of titanium implant for repairing/improving microenvironment of bone injury and promoting osseointegration
    Ding, Yao
    Tao, Bailong
    Ma, Ruichen
    Zhao, Xin
    Liu, Peng
    Cai, Kaiyong
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2023, 143 : 1 - 11
  • [43] Evaluation of mechanical behaviour of bone, implant and bone-implant interface by numerical simulation of two surgical fixation procedures using finite element analysis
    Devika, D.
    Arumaikkannu, G.
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2011, 42 (2-3) : 225 - 232
  • [44] Hydroxyapatite-electroplated cp-titanium implant and its bone integration potentiality:: An in vivo study
    Badr, Nadia A.
    El Hadary, Amany A.
    IMPLANT DENTISTRY, 2007, 16 (03) : 297 - 304
  • [45] Bone-implant interface and remaining tissues on the implant surface after push-out test: an SEM observation
    Li, JG
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1997, 7 (06) : 379 - 385
  • [46] Bio-activated titanium surface utilizable for mimetic bone implantation in dentistry -: Part III:: Surface characteristics and bone-implant contact formation
    Strnad, Jakub
    Strnad, Zdenek
    Sestak, Jaroslav
    Urban, Karel
    Povysil, Ctibor
    JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 2007, 68 (5-6) : 841 - 845
  • [47] A Method for Preparation of Samples of Titanium-Containing Bone-Implant Units for Assessing Osseointegration
    Kononovich, N. A.
    Litvinov, Yu Yu
    Gorbach, E. N.
    Popkov, A., V
    Krasnov, V. V.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2020, 54 (02): : 121 - 124
  • [48] Effect of Surface Nanotopography on Bone Response to Titanium Implant
    Freitas, Gileade P.
    Lopes, Helena B.
    Martins-Neto, Evandro C.
    de Oliveira, Paulo T.
    Beloti, Marcio M.
    Rosa, Adalberto L.
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (03) : 240 - 247
  • [49] Comparative Implant Stability of a Novel Implant-Porous Titanium Complex and an Implant-Porous Hydroxyapatite Complex for Bone Reconstruction Material
    Kobatake, Reiko
    Doi, Kazuya
    Wakamatsu, Kaien
    Oki, Yoshifumi
    Morita, Koji
    Tsuga, Kazuhiro
    JOURNAL OF HARD TISSUE BIOLOGY, 2023, 32 (03) : 177 - 182
  • [50] Control Variable Implants Improve Interpretation of Surface Modification and Implant Design Effects on Early Bone Responses: An In Vivo Study
    Choi, Jung-Yoo
    Kang, Seok-Hyung
    Kim, Hae-Young
    Yeo, In-Sung Luke
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (05) : 1033 - 1040