Monte Carlo modeling of electron beams from a NEPTUN 10PC medical linear accelerator

被引:0
|
作者
Jabbari, Nasrollah [2 ]
Hashemi-Malayeri, Bijan [1 ]
机构
[1] Tarbiat Modares Univ, Fac Med Sci, Dept Med Phys, Tehran 1411713116, Iran
[2] Urmia Univ Med Sci, Dept Med Imaging, Orumiyeh, Iran
关键词
Monte Carlo; radiotherapy; electron beams; linac; ENERGY; RADIOTHERAPY; DISTRIBUTIONS; RADIATION; DOSIMETRY;
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The Monte Carlo (MC) Simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. With the rapid development Of Computer technology, MC-based treatment planning for radiation therapy is becoming practical. A basic requirement for MC treatment planning is a detailed knowledge of radiation beams of medical linear accelerators (linacs). A practical approach to acquire this knowledge is to perform MC simulation of radiation transport for linacs. The aims of this study were: modeling of the electron beams from the NEPTUN 10PC linear accelerator (linac) with the MC method, obtaining of the energy spectra of electron beams, and providing the phase-space files for the electron beams of this linac at different field sizes. Electron beams produced by the linac were modeled using the BEAMnrc MC system. Central axis depth-dose curves and dose profiles of the electron beams were measured experimentally and also calculated with the MC system for different field sizes and energies. In order to benchmark the simulated models, the percent depth dose (PDD) and dose-profile curves calculated with the MC system were compared with those measured experimentally with diode detectors in an RFA 300 water phantom. The results of this study showed that the PDD and dose-profile curves calculated by the MC system using the phase-space data files matched well with the measured values. This study demonstrates that the MC phase-space data files can be used to generate accurate MC dose distributions for electron beams from NEPTUN 10PC medical linac.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 50 条
  • [1] A MULTIPLE SOURCE MONTE CARLO MODEL DEVELOPED FOR SIMULATING THE CLINICAL ELECTRON BEAMS OF NEPTUN 10PC MEDICAL LINAC
    Hashemi, B.
    Jabbari, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S401 - S402
  • [2] An intraoral cone system for a Neptun 10PC linear accelerator
    Shokrani, Parvaneh
    Soltani, Minoo
    [J]. NUKLEONIKA, 2011, 56 (04) : 381 - 384
  • [3] Monte Carlo simulation for Neptun 10 PC medical linear accelerator and calculations of output factor for electron beam
    Toossi, Mohammad Taghi Bahreyni
    Momennezhad, Mehdi
    Hashemi, Seyed Mohammad
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (02) : 115 - 118
  • [4] Modeling 6 MeV Electron Beam From Medical Linear Accelerator Using Monte Carlo Simulation
    Dechsupa, P.
    Tannanonta, C.
    Phaisangittisakul, N.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator
    Kyoung Won Jang
    Manwoo Lee
    Heuijin Lim
    Sang Koo Kang
    Sang Jin Lee
    Seung Heon Kim
    Dong Eun Lee
    Hee Chang Kim
    Dong Hyeok Jeong
    [J]. Journal of the Korean Physical Society, 2020, 76 : 588 - 591
  • [6] Monte Carlo Simulation of an Electron Irradiation Device for Medical Application of an Electron Linear Accelerator
    Jang, Kyoung Won
    Lee, Manwoo
    Lim, Heuijin
    Kang, Sang Koo
    Lee, Sang Jin
    Kim, Seung Heon
    Lee, Dong Eun
    Kim, Hee Chang
    Jeong, Dong Hyeok
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (07) : 588 - 591
  • [7] Monte Carlo calculations of electron beam output factors for a medical linear accelerator
    Kapur, A
    Ma, CM
    Mok, EC
    Findley, DO
    Boyer, AL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12): : 3479 - 3494
  • [8] Monte Carlo modelling of electron beams from medical accelerators
    Ma, CM
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : R157 - R189
  • [9] Monte Carlo simulation of electron beams from an accelerator head using PENELOPE
    Sempau, J
    Sánchez-Reyes, A
    Salvat, F
    ben Tahar, HO
    Jiang, SB
    Fernández-Varea, JM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1163 - 1186
  • [10] Monte Carlo simulation of a medical linear accelerator for radiotherapy use
    Serrano, B.
    Hachem, A.
    Franchisseur, E.
    Herault, J.
    Marcie, S.
    Costa, A.
    Bensadoun, R. J.
    Barthe, J.
    Gerard, J. P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 506 - 509