Monte Carlo modeling of electron beams from a NEPTUN 10PC medical linear accelerator

被引:0
|
作者
Jabbari, Nasrollah [2 ]
Hashemi-Malayeri, Bijan [1 ]
机构
[1] Tarbiat Modares Univ, Fac Med Sci, Dept Med Phys, Tehran 1411713116, Iran
[2] Urmia Univ Med Sci, Dept Med Imaging, Orumiyeh, Iran
关键词
Monte Carlo; radiotherapy; electron beams; linac; ENERGY; RADIOTHERAPY; DISTRIBUTIONS; RADIATION; DOSIMETRY;
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The Monte Carlo (MC) Simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. With the rapid development Of Computer technology, MC-based treatment planning for radiation therapy is becoming practical. A basic requirement for MC treatment planning is a detailed knowledge of radiation beams of medical linear accelerators (linacs). A practical approach to acquire this knowledge is to perform MC simulation of radiation transport for linacs. The aims of this study were: modeling of the electron beams from the NEPTUN 10PC linear accelerator (linac) with the MC method, obtaining of the energy spectra of electron beams, and providing the phase-space files for the electron beams of this linac at different field sizes. Electron beams produced by the linac were modeled using the BEAMnrc MC system. Central axis depth-dose curves and dose profiles of the electron beams were measured experimentally and also calculated with the MC system for different field sizes and energies. In order to benchmark the simulated models, the percent depth dose (PDD) and dose-profile curves calculated with the MC system were compared with those measured experimentally with diode detectors in an RFA 300 water phantom. The results of this study showed that the PDD and dose-profile curves calculated by the MC system using the phase-space data files matched well with the measured values. This study demonstrates that the MC phase-space data files can be used to generate accurate MC dose distributions for electron beams from NEPTUN 10PC medical linac.
引用
收藏
页码:233 / 238
页数:6
相关论文
共 50 条
  • [21] Modeling Cerenkov Emissions From Medical Linear Accelerators: A Monte Carlo Study
    Shrock, Z.
    Oldham, M.
    Adamson, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3580 - 3580
  • [22] Integration and evaluation of a DICOM interface in a Monte Carlo simulated medical linear accelerator
    Huertgen, G.
    Escobar-Corral, N.
    Schubert, C.
    Lotze, S.
    Schmachtenberg, A.
    Stahl, A.
    Eble, M. J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S180 - S180
  • [23] Sensitivity of large-field electron beams to variations in a Monte Carlo accelerator model
    Schreiber, EC
    Faddegon, BA
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 769 - 778
  • [24] Monte Carlo modelling of clinical accelerator beams and estimation of primary electron beam parameters
    Horova, S.
    Judas, L.
    RADIOPROTECTION, 2018, 53 (01) : 61 - 66
  • [25] Monte-Carlo simulations of a neutron source based on a linear electron accelerator
    Wasilewski, Adam
    Wronka, Slawomir
    NUKLEONIKA, 2025, 70 (01) : 3 - 10
  • [26] Benchmarking of electron beam parameters based on Monte Carlo linear accelerator simulation
    Zhang, Fan
    Zhou, Mi
    Liu, Jing
    Yue, Lu
    Deng, Lihua
    Xu, Zhijian
    Wang, Gang
    TRANSLATIONAL CANCER RESEARCH, 2020, 9 (02) : 577 - 584
  • [27] Monte-Carlo simulations of a neutron source generated with electron linear accelerator
    Wasilewski, Adam
    Wronka, Slawomir
    NUKLEONIKA, 2006, 51 (03) : 169 - 173
  • [28] Monte Carlo evaluation of the potential benefits of flattening filter free beams from the Oncor® clinical linear accelerator
    Asadi, Amin
    Razavi-Ratki, Seid Kazem
    Jabbari, Keyvan
    Najafzadeh, Milad
    Nickfarjam, Abolfazl
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (02) : 281 - 302
  • [29] Monte Carlo simulation of electron beams from medical linac using EGS5
    Nevelsky, A.
    Bar-Deroma, R.
    Orion, I.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S138 - S139
  • [30] Characteristics of radiosurgical beams from a Clinac 1800 accelerator: A Monte Carlo study
    Jiang, SB
    Ayyangar, KM
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 86 - 87