Dynamic measurements of total hepatic blood flow with Phase Contrast MRI

被引:32
|
作者
Yzet, Thierry [1 ]
Bouzerar, Roger [2 ]
Baledent, Olivier [2 ]
Renard, Cedric [1 ]
Lumbala, Didier Mbayo [1 ]
Nguyen-Khac, Eric [3 ]
Regimbeau, Jean-Marc [4 ]
Deramond, H. [1 ]
Meyer, Marc-Etienne [2 ]
机构
[1] Univ Hosp, Dept Radiol, F-80054 Amiens 1, France
[2] Jules Verne Univ Picardie, Univ Hosp, Dept Imaging & Biophys, F-80054 Amiens 1, France
[3] Univ Hosp, Mobile Unit Alcool, F-80054 Amiens 1, France
[4] Univ Hosp, Dept Visceral & Digest Gen Surg, F-80054 Amiens 1, France
关键词
PC-MRI; Hepatic hemodynamics; Hepatic artery; Portal vein; Total hepatic flow; MAGNETIC-RESONANCE; PORTAL-HYPERTENSION; CONTINUOUS INFUSION; INDOCYANINE GREEN; ECHO-DOPPLER; VENOUS FLOW; VOLUNTEERS; ULTRASOUND; ACCURACY; VOLUME;
D O I
10.1016/j.ejrad.2008.09.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background/Aims: To measure total hepatic blood flow including portal and proper hepatic artery flows as well as the temporal evolution of the vessel's section during a cardiac cycle. Methods: Twenty healthy subjects, with a mean age of 26 years, were explored. Magnetic resonance imaging blood flow measurements were carried out in the portal vein and the proper hepatic artery. MR studies were performed using a 1.5T imager (General Electric Medical Systems). Gradient-echo 2D Fast Cine Phase Contrast sequences were used with both cardiac and respiratory gatings. Data analysis was performed using a semi-automatic software built in our laboratory. Results: The total hepatic flow rate measured was 1.35 +/- 0.18 L/min or 19.7 +/- 4.6 mL/(min kg). The proper hepatic artery provided 19.1% of the total hepatic blood flow entering the liver. Those measurements were in agreement with earlier studies using direct measurements. Mean and maximum velocities were also assessed and a discrepancy between our values and the literature's Doppler data was found. Measurements of the portal vein area have shown a mean variation, defined as a "pulsatility" index of 18% over a cardiac cycle. Conclusions: We report here proper hepatic artery blood flow rate measurements using MRI. Associated with portal flow measurements, we have shown the feasibility of total hepatic flowmetry using a non-invasive and harmless technique. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [31] Oxytocin selectively reduces blood flow in uterine fibroids without an effect on myometrial blood flow: a dynamic contrast enhanced MRI evaluation
    Otonkoski, Saara
    Sainio, Teija
    Komar, Gaber
    Suomi, Visa
    Saunavaara, Jani
    Blanco Sequeiros, Roberto
    Perheentupa, Antti
    Joronen, Kirsi
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 1293 - 1300
  • [32] Automatic and Reproducible Positioning of Phase-Contrast MRI for the Quantification of Global Cerebral Blood Flow
    Liu, Peiying
    Lu, Hanzhang
    Filbey, Francesca M.
    Pinkham, Amy E.
    McAdams, Carrie J.
    Adinoff, Bryon
    Daliparthi, Vamsi
    Cao, Yan
    PLOS ONE, 2014, 9 (05):
  • [33] Blood flow quantification in adults by phase-contrast MRI combined with SENSE -: a validation study
    Beerbaum, P
    Körperich, H
    Gieseke, J
    Barth, P
    Peuster, M
    Meyer, H
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) : 361 - 369
  • [34] Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI
    Park, JB
    Santos, JM
    Hargreaves, BA
    Nayak, KS
    Sommer, G
    Hu, BS
    Nishimura, DG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (05) : 590 - 595
  • [35] Optimization of Phase-Contrast MRI for the Quantification of Whole-Brain Cerebral Blood Flow
    Peng, Shin-Lei
    Su, Pan
    Wang, Fu-Nien
    Cao, Yan
    Zhang, Rong
    Lu, Hanzhang
    Liu, Peiying
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) : 1126 - 1133
  • [36] Visualization of Orbital Flow by Means of Phase Contrast MRI
    Golzan, S. Mojtaba
    Avolio, Alberto
    Magnussen, John
    Graham, Stuart L.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3384 - 3387
  • [37] Phase Contrast MRI with Flow Compensation View Sharing
    Wang, Da
    Shao, Jiaxin
    Rapacchi, Stanislas
    Middione, Matthew J.
    Ennis, Daniel B.
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 505 - 513
  • [38] Phase contrast MRI measurements of net cerebrospinal fluid flow through the cerebral aqueduct are confounded by respiration
    Spijkerman, Jolanda M.
    Geurts, Lennart J.
    Siero, Jeroen C. W.
    Hendrikse, Jeroen
    Luijten, Peter R.
    Zwanenburg, Jaco J. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (02) : 433 - 444
  • [39] Noninvasive analysis of renal artery blood flow dynamics with MR cine phase-contrast flow measurements
    Schoenberg, SO
    Just, A
    Bock, M
    Knopp, MV
    Persson, PB
    Kirchheim, HR
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (05): : H2477 - H2484
  • [40] BLOOD FLOW PATTERN AND QUANTITATIVE STUDY IN SOLITARY PULMONARY NODULES WITH DYNAMIC CONTRAST-ENHANCED MRI
    杨春山
    肖湘生
    刘士远
    李慎江
    李惠民
    李成洲
    Medical Bulletin of Shanghai Jiaotong University, 2007, (01) : 41 - 45