Dynamic measurements of total hepatic blood flow with Phase Contrast MRI

被引:32
|
作者
Yzet, Thierry [1 ]
Bouzerar, Roger [2 ]
Baledent, Olivier [2 ]
Renard, Cedric [1 ]
Lumbala, Didier Mbayo [1 ]
Nguyen-Khac, Eric [3 ]
Regimbeau, Jean-Marc [4 ]
Deramond, H. [1 ]
Meyer, Marc-Etienne [2 ]
机构
[1] Univ Hosp, Dept Radiol, F-80054 Amiens 1, France
[2] Jules Verne Univ Picardie, Univ Hosp, Dept Imaging & Biophys, F-80054 Amiens 1, France
[3] Univ Hosp, Mobile Unit Alcool, F-80054 Amiens 1, France
[4] Univ Hosp, Dept Visceral & Digest Gen Surg, F-80054 Amiens 1, France
关键词
PC-MRI; Hepatic hemodynamics; Hepatic artery; Portal vein; Total hepatic flow; MAGNETIC-RESONANCE; PORTAL-HYPERTENSION; CONTINUOUS INFUSION; INDOCYANINE GREEN; ECHO-DOPPLER; VENOUS FLOW; VOLUNTEERS; ULTRASOUND; ACCURACY; VOLUME;
D O I
10.1016/j.ejrad.2008.09.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background/Aims: To measure total hepatic blood flow including portal and proper hepatic artery flows as well as the temporal evolution of the vessel's section during a cardiac cycle. Methods: Twenty healthy subjects, with a mean age of 26 years, were explored. Magnetic resonance imaging blood flow measurements were carried out in the portal vein and the proper hepatic artery. MR studies were performed using a 1.5T imager (General Electric Medical Systems). Gradient-echo 2D Fast Cine Phase Contrast sequences were used with both cardiac and respiratory gatings. Data analysis was performed using a semi-automatic software built in our laboratory. Results: The total hepatic flow rate measured was 1.35 +/- 0.18 L/min or 19.7 +/- 4.6 mL/(min kg). The proper hepatic artery provided 19.1% of the total hepatic blood flow entering the liver. Those measurements were in agreement with earlier studies using direct measurements. Mean and maximum velocities were also assessed and a discrepancy between our values and the literature's Doppler data was found. Measurements of the portal vein area have shown a mean variation, defined as a "pulsatility" index of 18% over a cardiac cycle. Conclusions: We report here proper hepatic artery blood flow rate measurements using MRI. Associated with portal flow measurements, we have shown the feasibility of total hepatic flowmetry using a non-invasive and harmless technique. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [21] Simulation of Phase Contrast MRI of Turbulent Flow
    Petersson, Sven
    Dyverfeldt, Petter
    Gardhagen, Roland
    Karlsson, Matts
    Ebbers, Tino
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (04) : 1039 - 1046
  • [22] Limits to flow detection in phase contrast MRI
    Williamson, Nathan H.
    Komlosh, Michal E.
    Benjamini, Dan
    Basser, Peter J.
    JOURNAL OF MAGNETIC RESONANCE OPEN, 2020, 2-3
  • [23] Blood Flow Computation in Phase-Contrast MRI by Minimal Paths in Anisotropic Media
    Schwerikel, Michael
    Hennemuth, Anja
    Fischer, Bernd
    Friman, Ola
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 436 - +
  • [24] Assessment of cerebral blood flow in neonates and infants: A phase-contrast MRI study
    Liu, Peiying
    Qi, Ying
    Lin, Zixuan
    Guo, Qiyong
    Wang, Xiaoming
    Lu, Hanzhang
    NEUROIMAGE, 2019, 185 : 926 - 933
  • [25] Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta
    Kim, Moon Sun
    Kweon, Dae Cheol
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2016, 26 (04): : 142 - 148
  • [26] Method to correct for the effects of limited spatial resolution in phase-contrast flow MRI measurements
    Lagerstrand, KM
    Lehmann, H
    Starck, G
    Vikhoff-Baaz, B
    Ekholm, S
    Forssell-Aronsson, E
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) : 883 - 889
  • [27] Estimation of cerebral blood flow from dynamic susceptibility contrast MRI using a tissue model
    Shimony, JS
    Lee, JJ
    Bretthorst, GL
    Bayesian Inference and Maximum Entropy Methods in Science and Engineering, 2005, 803 : 535 - 542
  • [28] Tracer delay correction of cerebral blood flow with dynamic susceptibility contrast-enhanced MRI
    Ibaraki, M
    Shimosegawa, E
    Toyoshima, H
    Takahashi, K
    Miura, S
    Kanno, I
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2005, 25 (03): : 378 - 390
  • [29] Imputation models and error analysis for phase contrast MR cerebral blood flow measurements
    Shah, Payal
    Doyle, Eamon
    Wood, John C.
    Borzage, Matthew T.
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [30] On the theoretical basis of perfusion measurements by dynamic susceptibility contrast MRI
    Kiselev, VG
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1113 - 1122