Mammography Diagnostic Reference Levels (DRLs) in Ghana

被引:12
|
作者
Dzidzornu, E. [1 ]
Angmorterh, S. K. [1 ]
Ofori-Manteaw, B. B. [1 ]
Aboagye, S. [2 ]
Dzefi-Tettey, K. [3 ]
Ofori, E. K. [1 ]
机构
[1] Univ Hlth & Allied Sci UHAS, Sch Allied Hlth Sci, Dept Med Imaging, Ho, Ghana
[2] Univ Hlth & Allied Sci UHAS, Sch Allied Hlth Sci, Dept Speech Language & Hearing Sci, Ho, Ghana
[3] Korle Bu Teaching Hosp, Dept Radiol, Accra, Ghana
关键词
Diagnostic reference levels; Average glandular dose; Mammography; Ghana; BREAST SCREENING-PROGRAM; IMAGE QUALITY; OPTIMIZATION;
D O I
10.1016/j.radi.2020.11.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Diagnostic Reference Levels (DRLs) are essential for optimisation in mammography. A local DRL for screen-film mammography has been established in Ghana but none exists for the digital mammography systems. Furthermore, technological advancement is phasing out the use of screen-film mammography and replacing it with digital mammography systems. This study aims to establish the local DRLs used in digital mammography across three institutions in Ghana to guide mammography practice. Methods: Average glandular dose (AGD), compressed breast thickness (CBT), age of patients, entrance surface exposure (ESE), kVp, and mAs were retrospectively extracted from three digital mammography systems. The 75th and 95th percentile values were obtained for the AGD of each mammography projection and at CBT of 60 +/- 5 mm. The correlation between the AGD and CBT, kVp, mAs, and ESE were investigated. Results: The 75th percentile for the AGD at CBT of 60 +/- 5 mm for Centres 1, 2, 3, and all centres were 2.3, 1.8, 2.1, and 2.0 mGy respectively. The DRLs obtained were comparably higher than international studies except those of the United Kingdom. The AGD showed a strong positive correlation with the CBT, kVp, mAs, and ESE. There was variability in the AGD applied across the three centres for the craniocaudal (CC) and mediolateral oblique (MLO) projections. The mean AGD, mAs, and ESE for all the three centres and per centre recorded were higher than previous studies, but the mean kVp and CBT were lower than previous studies. Conclusion: The higher DRLs estimated in this preliminary study indicates that there is a need for dose optimisation in digital mammography practice in Ghana to improve radiation protection. Implications for practice: The findings will guide the process of optimisation and limit the variations in the radiation dose during mammography practice. (C) 2020 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:611 / 616
页数:6
相关论文
共 50 条
  • [31] Establishment of regional diagnostic reference levels for digital mammography in Western Province of Sri Lanka
    Niroshani, H. S.
    Jeyasugiththan, Jeyasingam
    Senanayake, G.
    Negishi, Toru
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (01) : 79 - 96
  • [32] Local diagnostic reference levels for digital mammography: Two hospitals study in northwest, Nigeria
    Garba, I
    Bashir, H. S.
    Bello, F.
    Nuhu, K. S.
    Mohammed, S.
    Mansur, Y.
    Lawal, Y.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 435 - 442
  • [33] Mammography dose reference levels in practice
    Milano, F
    Lazzari, B
    del Turco, MR
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 195 - 198
  • [34] Reference (target) levels for mammography in Sweden
    Leitz, W
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 181 - 182
  • [35] Reference levels for image quality in mammography
    Zdesar, Urban
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 170 - 172
  • [36] Establishing national diagnostic reference levels in radiography, mammography, and dual-energy x-ray absorptiometry services in Ireland and comparing these with European diagnostic reference levels
    Lee O’Hora
    Noelle Neville
    John Tuffy
    Agnella Craig
    Kirsten O’Brien
    Kay Sugrue
    Maeve McGarry
    Brendan Duggan
    Sean Egan
    [J]. European Radiology, 2023, 33 : 9469 - 9478
  • [37] Establishing national diagnostic reference levels in radiography, mammography, and dual-energy x-ray absorptiometry services in Ireland and comparing these with European diagnostic reference levels
    O'Hora, Lee
    Neville, Noelle
    Tuffy, John
    Craig, Agnella
    O'Brien, Kirsten
    Sugrue, Kay
    McGarry, Maeve
    Duggan, Brendan
    Egan, Sean
    [J]. EUROPEAN RADIOLOGY, 2023, 33 (12) : 9469 - 9478
  • [38] Diagnostic Reference Levels
    Vassileva, Jenia
    Rehani, Madan
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (01) : W1 - W3
  • [39] Establishment of institutional Diagnostic Reference Levels for Computed Tomography examination at the University of Ghana Medical Centre
    Issahaku, Shirazu
    Amoh, Simon Mensah
    Acquah, Isaac Kwesi
    Nunoo, George
    Sackey, Theophilus A.
    [J]. HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1199 - 1207
  • [40] Establishment of national diagnostic reference levels for full field digital mammography and digital breast tomosynthesis in Lebanon
    Nassar, J.
    Rizk, C.
    Farah, J.
    Fares, G.
    [J]. RADIOPROTECTION, 2023, 58 (04) : 289 - 298