Mammography Diagnostic Reference Levels (DRLs) in Ghana

被引:12
|
作者
Dzidzornu, E. [1 ]
Angmorterh, S. K. [1 ]
Ofori-Manteaw, B. B. [1 ]
Aboagye, S. [2 ]
Dzefi-Tettey, K. [3 ]
Ofori, E. K. [1 ]
机构
[1] Univ Hlth & Allied Sci UHAS, Sch Allied Hlth Sci, Dept Med Imaging, Ho, Ghana
[2] Univ Hlth & Allied Sci UHAS, Sch Allied Hlth Sci, Dept Speech Language & Hearing Sci, Ho, Ghana
[3] Korle Bu Teaching Hosp, Dept Radiol, Accra, Ghana
关键词
Diagnostic reference levels; Average glandular dose; Mammography; Ghana; BREAST SCREENING-PROGRAM; IMAGE QUALITY; OPTIMIZATION;
D O I
10.1016/j.radi.2020.11.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Diagnostic Reference Levels (DRLs) are essential for optimisation in mammography. A local DRL for screen-film mammography has been established in Ghana but none exists for the digital mammography systems. Furthermore, technological advancement is phasing out the use of screen-film mammography and replacing it with digital mammography systems. This study aims to establish the local DRLs used in digital mammography across three institutions in Ghana to guide mammography practice. Methods: Average glandular dose (AGD), compressed breast thickness (CBT), age of patients, entrance surface exposure (ESE), kVp, and mAs were retrospectively extracted from three digital mammography systems. The 75th and 95th percentile values were obtained for the AGD of each mammography projection and at CBT of 60 +/- 5 mm. The correlation between the AGD and CBT, kVp, mAs, and ESE were investigated. Results: The 75th percentile for the AGD at CBT of 60 +/- 5 mm for Centres 1, 2, 3, and all centres were 2.3, 1.8, 2.1, and 2.0 mGy respectively. The DRLs obtained were comparably higher than international studies except those of the United Kingdom. The AGD showed a strong positive correlation with the CBT, kVp, mAs, and ESE. There was variability in the AGD applied across the three centres for the craniocaudal (CC) and mediolateral oblique (MLO) projections. The mean AGD, mAs, and ESE for all the three centres and per centre recorded were higher than previous studies, but the mean kVp and CBT were lower than previous studies. Conclusion: The higher DRLs estimated in this preliminary study indicates that there is a need for dose optimisation in digital mammography practice in Ghana to improve radiation protection. Implications for practice: The findings will guide the process of optimisation and limit the variations in the radiation dose during mammography practice. (C) 2020 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:611 / 616
页数:6
相关论文
共 50 条
  • [21] Proposed DRLs for mammography in Switzerland
    Dupont, Laura
    Aberle, Christoph
    Botsikas, Diomidis
    Ith, Michael
    Lima, Thiago Viana Miranda
    Menz, Roman
    Monnin, Pascal
    Poletti, Pierre-Alexandre
    Presilla, Stefano
    Schegerer, Alexander
    Stoica, Liana-Cristina
    Trueb, Philipp
    Merce, Marta Sans
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (02)
  • [22] Proposed diagnostic reference levels for general radiography and mammography in Japan
    Asada, Yasuki
    Kondo, Yuya
    Kobayashi, Masanao
    Kobayashi, Kenichi
    Ichikawa, Takuma
    Matsunaga, Yuta
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (03) : 867 - 876
  • [23] Diagnostic reference levels for digital mammography in New South Wales
    Suleiman, Moayyad E.
    McEntee, Mark F.
    Cartwright, Lucy
    Diffey, Jennifer
    Brennan, Patrick C.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (01) : 48 - 57
  • [24] ESTIMATION OF ADULT PATIENT DOSES FOR CHEST X-RAY EXAMINATIONS AND COMPARISON WITH DIAGNOSTIC REFERENCE LEVELS (DRLS)
    Mor, H. Bas
    Altinsoy, N.
    Soyler, I.
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 377 - 385
  • [25] Complexity-based local diagnostic reference levels (DRLs) for standard endovascular aneurysm repair (EVAR) procedures
    Tzanis, Eleftherios
    Ioannou, Christos V.
    Tsetis, Dimitrios
    Lioudaki, Stella
    Matthaiou, Nikolas
    Damilakis, John
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 89 - 94
  • [26] Glandular doses and diagnostic reference levels (DRLs) for Saudi breast cancer screening programme (2012-2021)
    Albeshan, Salman M.
    Alhulail, Ahmad A.
    Almuqbil, Maha M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2024, 200 (05) : 467 - 472
  • [27] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    [J]. HEALTH AND TECHNOLOGY, 2024,
  • [28] ESTIMATION OF SKIN ENTRANCE DOSES (SEDs) FOR COMMON MEDICAL X-RAY DIAGNOSTIC EXAMINATIONS IN INDIA AND PROPOSED DIAGNOSTIC REFERENCE LEVELS (DRLs)
    Sonawane, A. U.
    Shirva, V. K.
    Pradhan, A. S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 138 (02) : 129 - 136
  • [29] AVERAGE GLANDULAR DOSES AND NATIONAL DIAGNOSTIC REFERENCE LEVELS IN MAMMOGRAPHY EXAMINATIONS IN TURKEY
    Parmaksiz, Aydin
    Atac, Gokce K.
    Bulur, Emine
    Inal, Tolga
    Alhan, Aslihan
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 190 (01) : 100 - 107
  • [30] Establishment of dose reference levels (DRLs) for CT of the head and neck in radiation therapy
    Clerkin, C.
    Brennan, S.
    Mullaney, L.