Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system

被引:72
|
作者
Heiland, M
Schulze, D
Blake, F
Schmelzle, R
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Oral & Maxillofacial Surg, D-20246 Hamburg, Germany
[2] Univ Hamburg Hosp, Dept Oral Radiol, Hamburg, Germany
关键词
cone-beam computed tomography; SIREMOBIL; zygomaticomaxillary complex fracture;
D O I
10.1016/j.ijom.2004.09.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
After preclinical studies and evaluation of radiation exposures, intraoperative three-dimensional. (3D) C-arm based imaging is now available for the facial skeleton. Fourteen patients admitted for surgical treatment of zygomaticomaxillary complex (ZMC) fractures were included in the study. Preoperative diagnostics and surgical treatment were performed as usual. Intraoperatively, after open reduction, a cone-beam computed tomography (CBCT) dataset was generated using the SIREMOBIL Iso-C-3D (Siemens Medical Solutions, Erlangen, Germany). After DICOM-import in eFilm Workstation(TM) axial, coronal and sagittal reconstructions were evaluated by five examiners with the help of six defined criteria. In our study, secondary reconstructions were available after 6 min, excluding the time needed for the evaluation of the images. Especially the positioning of the isocentre of the SIREMOBIL Iso-C-3D proved to be uncomplicated. Because of the size of the datasets, assessment of the symmetry of the malar projection proved difficult. Best scoring results were found regarding the visualization of the fragment position, bony anchorage of the screws and the fitting of the plates. Remarkable was the low level of metal artefacts in primary and secondary reconstructions. In conclusion, our results demonstrate intraoperative CBCT using the SIREMOBIL Iso-C-3D suitable for assessment of postoperative results following ZMC reduction.
引用
收藏
页码:369 / 375
页数:7
相关论文
共 50 条
  • [1] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [2] Intraoperative Imaging With a 3D C-Arm System After Zygomatico-Orbital Complex Fracture Reduction
    Wilde, Frank
    Lorenz, Kai
    Ebner, Ann-Kathrin
    Krauss, Oliver
    Mascha, Frank
    Schramm, Alexander
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (05) : 894 - 910
  • [3] Intraoperative 3D C-arm imaging. State of the art
    von Recum, J.
    Wendl, K.
    Vock, B.
    Gruetzner, P. A.
    Franke, J.
    [J]. UNFALLCHIRURG, 2012, 115 (03): : 196 - 201
  • [4] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    Stubig, T.
    Aidarous, H.
    Khalifa, A.
    Omar, M.
    Krettek, C.
    Pacha, T. Omar
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1739 - 1743
  • [5] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    T. Stubig
    H. Aidarous
    A. Khalifa
    M. Omar
    C. Krettek
    T. Omar Pacha
    [J]. Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1739 - 1743
  • [6] Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation
    Hecht, Nils
    Yassin, Hadya
    Czabanka, Marcus
    Foehre, Bettina
    Arden, Klaus
    Liebig, Thomas
    Vajkoczy, Peter
    [J]. SPINE, 2018, 43 (05) : 370 - 377
  • [7] Intraoperative soft tissue 3D reconstruction with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    [J]. CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 200 - 206
  • [8] 3D soft tissue imaging with a mobile C-arm
    Ritter, Dieter
    Orman, Jasmina
    Schmidgunst, Christian
    Graumann, Rainer
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (02) : 91 - 102
  • [9] Intraoperative Cone-Beam Computed Tomography in Oral and Maxillofacial Surgery Using a C-Arm Prototype: First Clinical Experiences After Treatment of Zygomaticomaxillary Complex Fractures
    Pohlenz, Philipp
    Blake, Felix
    Blessmann, Marco
    Smeets, Ralf
    Habermann, Christian
    Begemann, Philipp
    Schmelzle, Rainer
    Heiland, Max
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (03) : 515 - 521
  • [10] Die intraoperative 3D-C-Bogen-AnwendungState of the artIntraoperative 3D C-arm imagingState of the art
    J. von Recum
    K. Wendl
    B. Vock
    P.A. Grützner
    J. Franke
    [J]. Der Unfallchirurg, 2012, 115 (3): : 196 - 201