Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study

被引:2
|
作者
Stubig, T. [1 ]
Aidarous, H. [1 ]
Khalifa, A. [1 ]
Omar, M. [1 ]
Krettek, C. [1 ]
Pacha, T. Omar [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
3D imaging; Femur fractures; Antetorsion measurements; Rotational alignement; Intraoperative imaging; COMPUTER-NAVIGATION; SYSTEM;
D O I
10.1007/s00402-020-03432-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim This study aims to test the accuracy and feasibility of a measurement of femoral torsion of a 3D C-arm system (Linea aspera method) in a cadaver setting. Materials and methods A total of 11 intact femora were used. Schanz screws were inserted in the femoral bone in a parallel manner with the help of a fixed drill sleeve. Femur bones were then fractured in a controlled manner and three different internal and external torsion angles were fixed with the help of a Goniometer. After that, a 3D scan was performed. The 3D data set was analyzed using a radiologic software (Visage 7, Visage Imaging Inc, USA). Measurements were then compared in the two methods with a dependent t test. Results Specific measurements for different angles did not show any differences between those two utilities. Conclusion Intraoperative estimation of femoral antetorsion using a 3D C-Arm system and the Linea aspera method seems to be an accurate and feasible method. Nevertheless, more studies with higher patient numbers, comparison to CT seems to be the next step and can be recommended.
引用
收藏
页码:1739 / 1743
页数:5
相关论文
共 50 条
  • [1] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    T. Stubig
    H. Aidarous
    A. Khalifa
    M. Omar
    C. Krettek
    T. Omar Pacha
    [J]. Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1739 - 1743
  • [2] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [3] Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system
    Heiland, M
    Schulze, D
    Blake, F
    Schmelzle, R
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (04) : 369 - 375
  • [4] Intraoperative 3D C-arm imaging. State of the art
    von Recum, J.
    Wendl, K.
    Vock, B.
    Gruetzner, P. A.
    Franke, J.
    [J]. UNFALLCHIRURG, 2012, 115 (03): : 196 - 201
  • [5] Intraoperative soft tissue 3D reconstruction with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    [J]. CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 200 - 206
  • [6] Intraoperative 2D C-arm and 3D O-arm in children: a comparative phantom study
    Prod'homme, M.
    Sans-Merce, M.
    Pitteloud, N.
    Damet, J.
    Lascombes, P.
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2018, 12 (05) : 550 - 557
  • [7] Die intraoperative 3D-C-Bogen-AnwendungState of the artIntraoperative 3D C-arm imagingState of the art
    J. von Recum
    K. Wendl
    B. Vock
    P.A. Grützner
    J. Franke
    [J]. Der Unfallchirurg, 2012, 115 (3): : 196 - 201
  • [8] Intraoperative C-arm fluoroscopy-based 3D navigation for intraventricular endoscopic intervention
    Herbowski, L.
    Sagan, L.
    Szylak, R.
    Salapa, P.
    Harat, A.
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2013, 27 (04) : 537 - 539
  • [9] Intraoperative Computed Tomography Versus 3D C-Arm Imaging for Navigated Spinal Instrumentation
    Hecht, Nils
    Yassin, Hadya
    Czabanka, Marcus
    Foehre, Bettina
    Arden, Klaus
    Liebig, Thomas
    Vajkoczy, Peter
    [J]. SPINE, 2018, 43 (05) : 370 - 377
  • [10] C-arm as intraoperative control in reduction of isolated zygomatic arch fractures: a randomized clinical trial
    Pedemonte C.
    Sáez F.
    Vargas I.
    González E.
    Canales M.
    Lazo D.
    Pérez H.
    [J]. Oral and Maxillofacial Surgery, 2016, 20 (1) : 79 - 83