Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system

被引:72
|
作者
Heiland, M
Schulze, D
Blake, F
Schmelzle, R
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Oral & Maxillofacial Surg, D-20246 Hamburg, Germany
[2] Univ Hamburg Hosp, Dept Oral Radiol, Hamburg, Germany
关键词
cone-beam computed tomography; SIREMOBIL; zygomaticomaxillary complex fracture;
D O I
10.1016/j.ijom.2004.09.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
After preclinical studies and evaluation of radiation exposures, intraoperative three-dimensional. (3D) C-arm based imaging is now available for the facial skeleton. Fourteen patients admitted for surgical treatment of zygomaticomaxillary complex (ZMC) fractures were included in the study. Preoperative diagnostics and surgical treatment were performed as usual. Intraoperatively, after open reduction, a cone-beam computed tomography (CBCT) dataset was generated using the SIREMOBIL Iso-C-3D (Siemens Medical Solutions, Erlangen, Germany). After DICOM-import in eFilm Workstation(TM) axial, coronal and sagittal reconstructions were evaluated by five examiners with the help of six defined criteria. In our study, secondary reconstructions were available after 6 min, excluding the time needed for the evaluation of the images. Especially the positioning of the isocentre of the SIREMOBIL Iso-C-3D proved to be uncomplicated. Because of the size of the datasets, assessment of the symmetry of the malar projection proved difficult. Best scoring results were found regarding the visualization of the fragment position, bony anchorage of the screws and the fitting of the plates. Remarkable was the low level of metal artefacts in primary and secondary reconstructions. In conclusion, our results demonstrate intraoperative CBCT using the SIREMOBIL Iso-C-3D suitable for assessment of postoperative results following ZMC reduction.
引用
收藏
页码:369 / 375
页数:7
相关论文
共 50 条
  • [31] Radiofrequency ablation under 3D intraoperative Iso-C C-arm navigation for the treatment of osteoid osteomas
    Yu, Feng
    Niu, Xiao-hui
    Zhang, Qing
    Zhao, Hai-tao
    Xu, Li-hui
    Deng, Zhi-ping
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1056):
  • [32] 3D imaging with an isocentric mobile C-arm - Comparison of image quality with spiral CT
    Kotsianos, D
    Wirth, S
    Fischer, T
    Euler, E
    Rock, C
    Linsenmaier, U
    Pfeifer, KJ
    Reiser, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (09) : 1590 - 1595
  • [33] Camera-augmented mobile C-arm (CAMC) application:: 3D reconstruction using a low-cost mobile C-arm
    Navab, N
    Mitschke, M
    Schütz, O
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 688 - 697
  • [34] Management of C1-2 traumatic fractures using an intraoperative 3D imaging-based navigation system
    Costa, Francesco
    Ortolina, Alessandro
    Attuati, Luca
    Cardia, Andrea
    Tomei, Massimo
    Riva, Marco
    Balzarini, Luca
    Fornari, Maurizio
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) : 128 - 133
  • [35] A cheap and easy method for 3D C-arm reconstruction using elliptic curves
    Burkhardt, David
    Jain, Ameet
    Fichtinger, Gabor
    [J]. MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [36] 3D reconstruction from projection matrices in a C-arm based 3D-angiography system
    Navab, N
    Bani-Hashemi, A
    Nadar, MS
    Wiesent, K
    Durlak, P
    Brunner, T
    Barth, K
    Graumann, R
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 119 - 129
  • [37] Preliminary study of integrated C-arm CT/SPECT imaging system for online adaptive 3D brachytherapy using Monte Carlo simulation
    Lee, M.
    Lee, H.
    Seong, S.
    Park, H.
    Kim, H.
    Min, C.
    Choi, H.
    Choa, H.
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [38] 3D-imaging using mobile low-end C-arm systems
    Lütjens, J
    Koppe, R
    Klotz, E
    Grass, M
    Rasche, V
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 901 - 912
  • [39] A method for extracting 3D information of cylinder in C-arm image
    Wu, Jian
    [J]. BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 544 - +
  • [40] Intraoperative assessment of hindfoot alignment using C-arm fluoroscopy
    Park, Young Uk
    Lee, Jong Wha
    Chung, Jun Young
    Choi, Wan-Sun
    Kim, Taehun
    Seo, Young Wook
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (05) : 1248 - 1254