3D-imaging using mobile low-end C-arm systems

被引:0
|
作者
Lütjens, J [1 ]
Koppe, R [1 ]
Klotz, E [1 ]
Grass, M [1 ]
Rasche, V [1 ]
机构
[1] Philips Res Labs, Hamburg, Germany
关键词
low-end C-arm systems; cone-beam reconstruction;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During the last years, three-dimensional X-ray imaging has become a well-established imaging modality, setting the golden standard for spatial resolution in three-dimensional X-ray imaging. Firstly introduced on a motorized C-arm system, it gained benefit from the high spatial resolution of the image intensifier. Using cone-beam reconstruction, it provided fast access to truly three-dimensional imaging with isotropic voxel dimensions. However, the non-rigid mechanics and the image distortion in the image intensifier required dedicated calibration processes and obligated the developers to use the most stable and reliable system in the C-arm device family. The need for system calibration also required the system to be able to reproducibly adjust the C-arm to the pre-calibrated positions, which seemed only possible with the motorized movement of a high-end system. On mobile, non-motorized C-arm systems, which are often used for guiding surgical procedures, however, 3D application has not been feasible due to the non-reproducibility of the mechanical movement. In this paper, first results regarding the feasibility of this approach are presented. The data were acquired on a Philips BV 26 surgical C-arm. This device is fully movable. The "C" arc is adjusted manually.
引用
收藏
页码:901 / 912
页数:12
相关论文
共 50 条
  • [1] 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D)
    Schulze, D
    Heiland, M
    Adam, G
    Schmelzle, R
    Rother, U
    [J]. RADIOLOGY, 2002, 225 : 565 - 565
  • [2] 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil ISO-C3D)
    Heiland, M
    Schulze, D
    Adam, G
    Schmelzle, R
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) : 21 - 25
  • [3] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [4] 3D soft tissue imaging with a mobile C-arm
    Ritter, Dieter
    Orman, Jasmina
    Schmidgunst, Christian
    Graumann, Rainer
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (02) : 91 - 102
  • [5] Camera-augmented mobile C-arm (CAMC) application:: 3D reconstruction using a low-cost mobile C-arm
    Navab, N
    Mitschke, M
    Schütz, O
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 688 - 697
  • [6] 3D X-ray imaging of human bones using a mobile C-arm
    Lütjens, J
    Koppe, R
    Klotz, E
    Grass, M
    Rasche, V
    [J]. CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1016 - 1016
  • [7] CT Imaging with a mobile C-arm prototype
    Cheryauka, Arvi
    Tubbs, Dave
    Langille, Vinton
    Kalya, Prabhanjana
    Smith, Brady
    Cherone, Rocco
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [8] Fusion Imaging for EVAR with Mobile C-arm
    Kaladji, Adrien
    Villena, Alexandre
    Pascot, Remy
    Lalys, Florent
    Daoudal, Anne
    Clochard, Elodie
    Lucas, Antoine
    Cardon, Alain
    [J]. ANNALS OF VASCULAR SURGERY, 2019, 55 : 166 - 174
  • [9] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [10] 3D imaging with an isocentric mobile C-arm - Comparison of image quality with spiral CT
    Kotsianos, D
    Wirth, S
    Fischer, T
    Euler, E
    Rock, C
    Linsenmaier, U
    Pfeifer, KJ
    Reiser, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (09) : 1590 - 1595