Intraoperative Cone-Beam Computed Tomography in Oral and Maxillofacial Surgery Using a C-Arm Prototype: First Clinical Experiences After Treatment of Zygomaticomaxillary Complex Fractures

被引:36
|
作者
Pohlenz, Philipp [1 ]
Blake, Felix
Blessmann, Marco
Smeets, Ralf [3 ]
Habermann, Christian [2 ]
Begemann, Philipp [2 ]
Schmelzle, Rainer
Heiland, Max
机构
[1] Univ Med Ctr hamburg Eppendorf, Nord W Deutsch Kieferklin, Dept Oral & Maxillofacial Surg, D-20246 Hamburg, Germany
[2] Univ Med Ctr hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[3] Univ Hosp Aachen, Dept Oral & Maxillofacial Surg, Aachen, Germany
关键词
ENDOSCOPIC SINUS SURGERY; GUIDED SURGERY; GUIDANCE; MOBILE; IMPLEMENTATION; TECHNOLOGY; SYSTEM; HEAD; NECK;
D O I
10.1016/j.joms.2008.06.086
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To describe the first clinical applications of intraoperative cone-beam computed tomography with an integrated flat-panel detector in oral and maxillofacial surgery after surgical treatment of zygomaticomaxillary complex fractures. Patients and Methods: Nine cone-beam computed tomography datasets of patients with zygomaticomaxillary complex fractures were intraoperatively acquired using a mobile isocentric C-arm (PowerMobil; Siemens Medical Solutions, Erlangen, Germany), including a flat-panel detector. Datasets based on 400, 200, and 100 fluoroscopic images were performed with different tube currents (4.6 mA, 3.3 mA, 2.3 mA, 1.2 mA, and 0.5 mA) and a current tube voltage of 100 kV. Postprocessing resulted in 15 different datasets available for comparison with corresponding preoperative computed tomography datasets. Four oral and maxillofacial surgeons and 2 experienced radiologists evaluated each dataset regarding noise, transition, and the delimitation of landmarks. Results: All examinations were successfully performed. Reconstructed datasets showed high-resolution images of all midfacial osseous structures in near-computed tomography quality. Regarding high-contrast structures, detailed analyses of datasets acquired in this study, suggest that the parameters 400 projections, 1.2 mA, and 100 kV are sufficient. In terms of soft-tissue visualization, a higher level of mA seems preferable. Conclusions: The tested prototype predicts a new era in cone-beam computed tomography imaging. The integration of a flat-panel detector will overcome the limitations of current available systems. The size of the field of view is increased allowing regularly the visualization of the whole facial skeleton. Particularly in cases of open reduction of unilateral fractures, the assessment of symmetry is of clinical value. (C) 2009 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:515 / 521
页数:7
相关论文
共 50 条
  • [1] Clinical indications and perspectives for intraoperative cone-beam computed tomography in oral and maxillofacial surgery
    Pohlenz, Philipp
    Blessmann, Marco
    Blake, Felix
    Heinrich, Sven
    Schmelzle, Rainer
    Heiland, Max
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (03): : 412 - 417
  • [2] Applications of cone-beam computed tomography in fractures of the maxillofacial complex
    Shintaku, Werner H.
    Venturin, Jaqueline S.
    Azevedo, Bruno
    Noujeim, Marcel
    [J]. DENTAL TRAUMATOLOGY, 2009, 25 (04) : 358 - 366
  • [3] Intraoperative cone-beam CT for head and neck surgery: Feasibility of clinical implementation using a prototype mobile C-arm
    King, Emma
    Daly, Michael J.
    Chan, Harley
    Bachar, Gideon
    Dixon, Benjamin J.
    Siewerdsen, Jeffrey H.
    Irish, Jonathan C.
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2013, 35 (07): : 959 - 967
  • [4] Intraoperative C-arm cone-beam computed tomography: Quantitative analysis of surgical performance in skull base surgery
    Lee, Stella
    Gallia, Gary L.
    Reh, Douglas D.
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Nithiananthan, Sajendra
    Otake, Yoshito
    Stayman, J. Webster
    Zbijewski, Wojciech
    Siewerdsen, Jeffrey H.
    [J]. LARYNGOSCOPE, 2012, 122 (09): : 1925 - 1932
  • [5] Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endo grafting
    Dijkstra, Martijn L.
    Eagleton, Matthew J.
    Greenberg, Roy K.
    Mastracci, Tara
    Hernandez, Adrian
    [J]. JOURNAL OF VASCULAR SURGERY, 2011, 53 (03) : 583 - 590
  • [6] Use of robotic C-arm cone-beam computed tomography in surgical stabilization of rib fractures
    Yen, Ming-Hong
    Liu, Tsu-Hao
    Liu, Jung -Sen
    Yim, Shelly
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (12):
  • [7] Respiratory correlated cone-beam computed tomography on an isocentric C-arm
    Kriminski, S
    Mitschke, M
    Sorensen, S
    Wink, NM
    Chow, PE
    Tenn, S
    Solberg, TD
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (22): : 5263 - 5280
  • [8] Cone-Beam Computed Tomography on a Mobile C-Arm: Novel Intraoperative Imaging Technology for Guidance of Head and Neck Surgery
    Chan, Yvonne
    Siewerdsen, Jeffrey H.
    Rafferty, Mark A.
    Moseley, Douglas J.
    Jaffray, David A.
    Irish, Jonathan C.
    [J]. JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2008, 37 (01): : 81 - 90
  • [9] C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Chiara Floridi
    Alessandro Radaelli
    Nadine Abi-Jaoudeh
    Micheal Grass
    Ming De Lin
    Melanie Chiaradia
    Jean-Francois Geschwind
    Hishman Kobeiter
    Ettore Squillaci
    Geert Maleux
    Andrea Giovagnoni
    Luca Brunese
    Bradford Wood
    Gianpaolo Carrafiello
    Antonio Rotondo
    [J]. La radiologia medica, 2014, 119 : 521 - 532
  • [10] C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Floridi, Chiara
    Radaelli, Alessandro
    Abi-Jaoudeh, Nadine
    Grass, Micheal
    De Lin, Ming
    Chiaradia, Melanie
    Geschwind, Jean-Francois
    Kobeiter, Hishman
    Squillaci, Ettore
    Maleux, Geert
    Giovagnoni, Andrea
    Brunese, Luca
    Wood, Bradford
    Carrafiello, Gianpaolo
    Rotondo, Antonio
    [J]. RADIOLOGIA MEDICA, 2014, 119 (07): : 521 - 532