Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy

被引:0
|
作者
Siebig, Sylvia [1 ]
Rockmann, Felix [1 ]
Sabel, Karl [1 ]
Zuber-Jerger, Ina [1 ]
Dierkes, Christine [1 ]
Bruennler, Tanja [1 ]
Wrede, Christian E. [1 ]
机构
[1] Univ Regensburg, Dept Internal Med 1, D-93042 Regensburg, Germany
来源
关键词
continuous non-invasive blood pressure; procedural sedation; endoscopy; cardiovascular monitoring; hypotension; GASTROINTESTINAL ENDOSCOPY; TRAINED NONANESTHESIOLOGISTS; PROPOFOL; SEDATION; PROTOCOL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Close monitoring of arterial blood pressure (BP) is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP). Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP (R), CN Systems, Graz) may improve patient safety in those settings. We investigated if this new technique improved monitoring of patients undergoing interventional endoscopy. Methods: 40 patients undergoing interventional endoscopy between April and December 2007 were prospectively studied with CNAP (R) in addition to standard monitoring (NIBP, ECG and oxygen saturation). All monitoring values were extracted from the surveillance network at one-second intervals, and clinical parameters were documented. The variance of CNAP (R) values were calculated for every interval between two NIBP measurements. Results: 2660 minutes of monitoring were recorded (mean 60.1 +/- 34.4 min/patient). All patients were analgosedated with midazolam and pethidine, and 24/40 had propofol infusion (mean 90.9 +/- 70.3 mg). The mean arterial pressure for CNAP (R) was 102.4 +/- 21.2 mmHg and 106.8 +/- 24.8 mmHg for NIBP. Based on the first NIBP value in an interval between two NIBP measurements, BP values determined by CNAP (R) showed a maximum increase of 30.8 +/- 21.7% and a maximum decrease of 22.4 +/- 28.3% (mean of all intervals). Discussion: Conventional intermittent blood pressure monitoring of patients receiving sedating agents failed to detect fast changes in BP. The new technique CNAP (R) improved the detection of rapid BP changes, and may contribute to a better patient safety for those undergoing interventional procedures.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [41] Radial artery tonometry: Moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement
    Weiss, BM
    Spahn, DR
    Rahmig, H
    Rohling, R
    Pasch, T
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (03) : 405 - 411
  • [42] Effectiveness of using non-invasive continuous arterial pressure monitoring with ClearSight in hemodynamic monitoring during living renal transplantation in a recipient : a case report
    Kakuta, Nami
    Tsutsumi, Yasuo M.
    Murakami, Chiaki
    Sakai, Yoko
    Oyama, Takuro
    Kasai, Asuka
    Kume, Katsuyoshi
    Tanaka, Katsuya
    JOURNAL OF MEDICAL INVESTIGATION, 2018, 65 (1-2): : 139 - 141
  • [43] Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery
    Hofhuizen, C. M.
    Lemson, J.
    Hemelaar, A. E. A.
    Settels, J. J.
    Schraa, O.
    Singh, S. K.
    van der Hoeven, J. G.
    Scheffer, G. J.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (04) : 493 - 500
  • [44] Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement
    Ilies, C.
    Kiskalt, H.
    Siedenhans, D.
    Meybohm, P.
    Steinfath, M.
    Bein, B.
    Hanss, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (03) : 413 - 419
  • [45] The impact of continuous non-invasive arterial blood pressure monitoring on blood pressure stability during general anaesthesia in orthopaedic patients A randomised trial
    Meidert, Agnes S.
    Nold, Johanna S.
    Hornung, Roman
    Paulus, Alexander C.
    Zwissler, Bernhard
    Czerner, Stephan
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2017, 34 (11) : 716 - 722
  • [46] NON-INVASIVE AUTOMATIC MONITORING OF INSTANTANEOUS ARTERIAL BLOOD-PRESSURE USING THE VASCULAR UNLOADING TECHNIQUE
    YAMAKOSHI, K
    KAMIYA, A
    SHIMAZU, H
    ITO, H
    TOGAWA, T
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (05) : 557 - 565
  • [47] Arterial blood pressure monitoring in overweight critically ill patients: Invasive or non-invasive?
    Bander, JJ
    Guzman, JA
    Araghi, A
    CHEST, 2004, 126 (04) : 746S - 747S
  • [48] Control Method for Continuous Non-Invasive Arterial Pressure Monitoring using the Non-Pulsatile Component of the PPG Signal
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Kaisti, Matti
    2021 COMPUTING IN CARDIOLOGY (CINC), 2021,
  • [49] INVASIVE VS NON-INVASIVE ARTERIAL PRESSURE MONITORING: DO THEY MONITOR THE SAME THING?
    Drimousis, P.
    Giakis, N.
    Larentzakis, A.
    Papanikolaou, M.
    Mpalla, M.
    Charalambous, A.
    Kofinas, G.
    INTENSIVE CARE MEDICINE, 2009, 35 : 230 - 230
  • [50] Non-invasive continuous blood pressure monitoring: a review of current applications
    Elena Chung
    Guo Chen
    Brenton Alexander
    Maxime Cannesson
    Frontiers of Medicine, 2013, 7 : 91 - 101