Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy

被引:0
|
作者
Siebig, Sylvia [1 ]
Rockmann, Felix [1 ]
Sabel, Karl [1 ]
Zuber-Jerger, Ina [1 ]
Dierkes, Christine [1 ]
Bruennler, Tanja [1 ]
Wrede, Christian E. [1 ]
机构
[1] Univ Regensburg, Dept Internal Med 1, D-93042 Regensburg, Germany
来源
关键词
continuous non-invasive blood pressure; procedural sedation; endoscopy; cardiovascular monitoring; hypotension; GASTROINTESTINAL ENDOSCOPY; TRAINED NONANESTHESIOLOGISTS; PROPOFOL; SEDATION; PROTOCOL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Close monitoring of arterial blood pressure (BP) is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP). Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP (R), CN Systems, Graz) may improve patient safety in those settings. We investigated if this new technique improved monitoring of patients undergoing interventional endoscopy. Methods: 40 patients undergoing interventional endoscopy between April and December 2007 were prospectively studied with CNAP (R) in addition to standard monitoring (NIBP, ECG and oxygen saturation). All monitoring values were extracted from the surveillance network at one-second intervals, and clinical parameters were documented. The variance of CNAP (R) values were calculated for every interval between two NIBP measurements. Results: 2660 minutes of monitoring were recorded (mean 60.1 +/- 34.4 min/patient). All patients were analgosedated with midazolam and pethidine, and 24/40 had propofol infusion (mean 90.9 +/- 70.3 mg). The mean arterial pressure for CNAP (R) was 102.4 +/- 21.2 mmHg and 106.8 +/- 24.8 mmHg for NIBP. Based on the first NIBP value in an interval between two NIBP measurements, BP values determined by CNAP (R) showed a maximum increase of 30.8 +/- 21.7% and a maximum decrease of 22.4 +/- 28.3% (mean of all intervals). Discussion: Conventional intermittent blood pressure monitoring of patients receiving sedating agents failed to detect fast changes in BP. The new technique CNAP (R) improved the detection of rapid BP changes, and may contribute to a better patient safety for those undergoing interventional procedures.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [31] Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring
    Digiglio, Philip
    Li, Ruya
    Wang, Wenqi
    Pan, Tingrui
    ANNALS OF BIOMEDICAL ENGINEERING, 2014, 42 (11) : 2278 - 2288
  • [32] Continuous non-invasive vs. invasive arterial blood pressure monitoring during neuroradiological procedure: a comparative, prospective, monocentric, observational study
    Chapalain, Xavier
    Morvan, Thomas
    Gentric, Jean-Christophe
    Subileau, Aurelie
    Jacob, Christophe
    Cadic, Anna
    Caillard, Anais
    Huet, Olivier
    PERIOPERATIVE MEDICINE, 2024, 13 (01)
  • [33] Continuous non-invasive arterial pressure measurement: Evaluation of CNAP™ device during vascular surgery
    Biais, M.
    Vidil, L.
    Roullet, S.
    Masson, F.
    Quinart, A.
    Revel, P.
    Sztark, F.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2010, 29 (7-8): : 530 - 535
  • [34] MONITORING LOW BLOOD-PRESSURE - NON-INVASIVE TECHNIQUE
    THICK, MG
    THICK, GC
    ANAESTHESIA, 1978, 33 (08) : 726 - 728
  • [35] ANALYSIS FOR NON-INVASIVE DETERMINATION OF ARTERIAL PROPERTIES AND FOR TRANS-CUTANEOUS CONTINUOUS MONITORING OF ARTERIAL BLOOD-PRESSURE
    GHISTA, DN
    JAYARAMAN, G
    SANDLER, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (06) : 715 - 726
  • [36] Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial
    Jan Benes
    Alena Simanova
    Tereza Tovarnicka
    Silvie Sevcikova
    Jakub Kletecka
    Jan Zatloukal
    Richard Pradl
    Ivan Chytra
    Eduard Kasal
    Journal of Clinical Monitoring and Computing, 2015, 29 : 11 - 17
  • [37] Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial
    Benes, Jan
    Simanova, Alena
    Tovarnicka, Tereza
    Sevcikova, Silvie
    Kletecka, Jakub
    Zatloukal, Jan
    Pradl, Richard
    Chytra, Ivan
    Kasal, Eduard
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 11 - 17
  • [38] Continuous non-invasive arterial blood pressure monitoring with photoplethysmography via SE-MSResUNet network
    Ma, Ke
    Zou, Lili
    Yang, Feng
    Zhan, Chang'an A.
    Gong, Yao
    Huang, Dequn
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 90
  • [39] Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients
    Hohn, A.
    Defosse, J. M.
    Becker, S.
    Steffen, C.
    Wappler, F.
    Sakka, S. G.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (02) : 178 - 184
  • [40] Monitoring of hypotension after spinal anesthesia in cesarean section with continuous non-invasive arterial pressure measurement
    Han, Chao
    Huang, Shaoqiang
    Lu, Yaojun
    Li, Ning
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (09): : 18300 - 18307