Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy

被引:0
|
作者
Siebig, Sylvia [1 ]
Rockmann, Felix [1 ]
Sabel, Karl [1 ]
Zuber-Jerger, Ina [1 ]
Dierkes, Christine [1 ]
Bruennler, Tanja [1 ]
Wrede, Christian E. [1 ]
机构
[1] Univ Regensburg, Dept Internal Med 1, D-93042 Regensburg, Germany
来源
关键词
continuous non-invasive blood pressure; procedural sedation; endoscopy; cardiovascular monitoring; hypotension; GASTROINTESTINAL ENDOSCOPY; TRAINED NONANESTHESIOLOGISTS; PROPOFOL; SEDATION; PROTOCOL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Close monitoring of arterial blood pressure (BP) is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP). Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP (R), CN Systems, Graz) may improve patient safety in those settings. We investigated if this new technique improved monitoring of patients undergoing interventional endoscopy. Methods: 40 patients undergoing interventional endoscopy between April and December 2007 were prospectively studied with CNAP (R) in addition to standard monitoring (NIBP, ECG and oxygen saturation). All monitoring values were extracted from the surveillance network at one-second intervals, and clinical parameters were documented. The variance of CNAP (R) values were calculated for every interval between two NIBP measurements. Results: 2660 minutes of monitoring were recorded (mean 60.1 +/- 34.4 min/patient). All patients were analgosedated with midazolam and pethidine, and 24/40 had propofol infusion (mean 90.9 +/- 70.3 mg). The mean arterial pressure for CNAP (R) was 102.4 +/- 21.2 mmHg and 106.8 +/- 24.8 mmHg for NIBP. Based on the first NIBP value in an interval between two NIBP measurements, BP values determined by CNAP (R) showed a maximum increase of 30.8 +/- 21.7% and a maximum decrease of 22.4 +/- 28.3% (mean of all intervals). Discussion: Conventional intermittent blood pressure monitoring of patients receiving sedating agents failed to detect fast changes in BP. The new technique CNAP (R) improved the detection of rapid BP changes, and may contribute to a better patient safety for those undergoing interventional procedures.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 50 条
  • [21] CONTINUOUS NON-INVASIVE ARTERIAL PRESSURE (CNAP) MEASUREMENT: COMPARING THE CNAP DEVICE TO THE NON-INVASIVE BLOOD PRESSURE ARM CUFF DURING SURGERY
    Khera, J. K.
    Solangasenathirajan, S.
    Jones, M.
    Jonas, M.
    INTENSIVE CARE MEDICINE, 2013, 39 : S295 - S295
  • [22] Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery
    Fischer, M. O.
    Avram, R.
    Carjaliu, I.
    Massetti, M.
    Gerard, J. L.
    Hanouz, J. L.
    Fellahi, J. L.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (04) : 514 - 521
  • [23] Continuous Non-Invasive Arterial Pressure Monitoring To Detect Autonomic Dysfunction in Parkinson's Disease
    Hellman, Amy
    Duda, John
    Morley, James
    NEUROLOGY, 2013, 80
  • [24] Continuous cardiac output monitoring in humans by non-invasive arterial blood pressure waveform analysis
    Lu, Z
    Mukkamala, R
    Computers in Cardiology 2005, Vol 32, 2005, 32 : 841 - 844
  • [25] Evaluation of continuous non-invasive arterial pressure monitoring during induction of general anaesthesia in patients undergoing cardiac surgery
    Kumar, Anil G.
    Jagadeesh, A. M.
    Singh, Naveen G.
    Prasad, S. R.
    INDIAN JOURNAL OF ANAESTHESIA, 2015, 59 (01) : 21 - 25
  • [26] Precision and accuracy of a new device (CNAP™) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia
    Jeleazcov, C.
    Krajinovic, L.
    Muenster, T.
    Birkholz, T.
    Fried, R.
    Schuettler, J.
    Fechner, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (03) : 264 - 272
  • [27] Optoacoustic technique for non-invasive continuous monitoring of blood oxygenation
    Esenaliev, RO
    Larin, KV
    Larina, IV
    Motamedi, M
    Prough, DS
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 272 - 274
  • [28] NON-INVASIVE CONTINUOUS MONITORING OF SYSTEMIC BLOOD-PRESSURE
    SPORTICHE, M
    JARDIN, F
    BOUROKBA, A
    MARGAIRAZ, A
    NOUVELLE PRESSE MEDICALE, 1980, 9 (18): : 1306 - &
  • [29] Continuous Non-Invasive Blood Pressure Monitoring Using Photoplethysmography
    Nye, Ross
    Zhang, Zhe
    Fang, Qiang
    2015 INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2015, : 176 - 179
  • [30] Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring
    Philip Digiglio
    Ruya Li
    Wenqi Wang
    Tingrui Pan
    Annals of Biomedical Engineering, 2014, 42 : 2278 - 2288