Cardiac spiral dual-source CT with high pitch: a feasibility study

被引:53
|
作者
Ertel, Dirk [1 ]
Lell, Michael M. [2 ]
Harig, Frank [3 ]
Flohr, Thomas [4 ]
Schmidt, Bernhard [4 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Radiol, D-91052 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Ctr Cardiac Surg, D-91052 Erlangen, Germany
[4] Siemens Healthcare, Forchheim, Germany
关键词
Dual-source CT; Cardiac imaging; Image quality; Dose; High pitch; TOMOGRAPHY CORONARY-ANGIOGRAPHY; MULTISLICE COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RADIATION-EXPOSURE; SHOOT MODE; PERFORMANCE; HEART; VALIDATION; MODULATION; REDUCTION;
D O I
10.1007/s00330-009-1503-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Increase of pitch in spiral CT decreases data acquisition time; dual-source CT (DSCT) systems provide improved temporal resolution. We evaluated the combination of these two features. Measurements were performed using a commercial DSCT system equipped with prototype software allowing pitch factors from p=0.35 to 3.0. We measured slice sensitivity profiles as a function of pitch to assess spatial resolution in the z-direction and the contrast of structures moved periodically to measure temporal resolution. Additionally we derived modulation transfer functions to provide objective parameters; both spatial and temporal resolution were essentially unchanged even at high pitch. CT of the cardiac region of three pigs was performed at p=3.0. In vivo CT images confirmed good image quality; direct comparison with standard low-pitch phase-correlated CT image datasets showed no significant difference. For a normalized z-axis acquisition of 12 cm, the corresponding effective dose value was 2.0 mSv for the high-pitch CT protocol. We conclude that spiral DSCT imaging with a pitch of 3.0 can provide unimpaired image quality with respect to spatial and temporal resolution. Applications to cardiac and thoracic imaging with effective dose below 1 mSv are possible.
引用
收藏
页码:2357 / 2362
页数:6
相关论文
共 50 条
  • [1] Cardiac spiral dual-source CT with high pitch: a feasibility study
    Dirk Ertel
    Michael M. Lell
    Frank Harig
    Thomas Flohr
    Bernhard Schmidt
    Willi A. Kalender
    European Radiology, 2009, 19 : 2357 - 2362
  • [2] Feasibility and Radiation Dose of High-Pitch Acquisition Protocols in Patients Undergoing Dual-Source Cardiac CT
    Sommer, Wieland H.
    Albrecht, Edda
    Bamberg, Fabian
    Schenzle, Jan C.
    Johnson, Thorsten R.
    Neumaier, Klement
    Reiser, Maximilian F.
    Nikolaou, Konstatin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1306 - 1312
  • [3] Feasibility of high-pitch dual-source low-dose chest CT: Reduction of radiation and cardiac artifacts
    Lim, H. K.
    Ha, H. I.
    Hwang, H. J.
    Lee, K.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 443 - 449
  • [4] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Yang, Wen Jie
    Chen, Ke Min
    Liu, Bo
    Pang, Li Fang
    Zhang, Huan
    Pan, Zi Lai
    Yan, Fu Hua
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01): : 245 - 252
  • [5] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Wen Jie Yang
    Ke Min Chen
    Bo Liu
    Li Fang Pang
    Huan Zhang
    Zi Lai Pan
    Fu Hua Yan
    The International Journal of Cardiovascular Imaging, 2013, 29 : 245 - 252
  • [6] The feasibility of high-pitch acquisition protocol for imaging of the pediatric abdomen by dual-source CT
    Eray Atlı
    Erhan Akpınar
    Emre Ünal
    Berna Oğuz Sayan
    Mithat Haliloğlu
    Japanese Journal of Radiology, 2018, 36 : 437 - 443
  • [7] The feasibility of high-pitch acquisition protocol for imaging of the pediatric abdomen by dual-source CT
    Atli, Eray
    Akpinar, Erhan
    Unal, Emre
    Sayan, Berna Oguz
    Haliloglu, Mithat
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (07) : 437 - 443
  • [8] High pitch third generation dual-source CT: Coronary and cardiac visualization on routine chest CT
    Sandfort, Veit
    Ahlman, Mark A.
    Jones, Elizabeth C.
    Selwaness, Mariana
    Chen, Marcus Y.
    Folio, Les R.
    Bluemke, David A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (04) : 282 - 288
  • [9] Feasibility of high-pitch spiral dual-source CT angiography in children with complex congenital heart disease compared to retrospective-gated spiral acquisition
    Li, T.
    Zhao, S.
    Liu, J.
    Yang, L.
    Huang, Z.
    Li, J.
    Luo, C.
    Li, X.
    CLINICAL RADIOLOGY, 2017, 72 (10) : 864 - 870
  • [10] Effect of High-Pitch Dual-Source CT to Compensate Motion Artifacts: A Phantom Study
    Farshad-Amacker, Nadia A.
    Alkadhi, Hatem
    Leschka, Sebastian
    Frauenfelder, Thomas
    ACADEMIC RADIOLOGY, 2013, 20 (10) : 1234 - 1239