Development and commissioning of a Monte Carlo photon beam model for the forthcoming clinical trials in microbeam radiation therapy

被引:54
|
作者
Martinez-Rovira, I. [1 ,2 ]
Sempau, J. [2 ]
Prezado, Y. [1 ]
机构
[1] European Synchrotron Radiat Facil, Biomed Beamline ID17, F-38043 Grenoble, France
[2] Univ Politecn Cataluna, Inst Tecn Energet, E-08028 Barcelona, Spain
关键词
synchrotron radiation; microbeam radiation therapy; Monte Carlo simulations; clinical trials; RADIOCHROMIC FILM DOSIMETRY; HIGH-SPATIAL-RESOLUTION; X-RAY-BEAMS; IRRADIATION GEOMETRY; MICROPLANAR BEAMS; DOSE ENHANCEMENT; 9L GLIOSARCOMA; SYNCHROTRON; BRAIN; SIMULATION;
D O I
10.1118/1.3665768
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A new radiotherapy technique, named microbeam radiation therapy (MRT), is under development at the ID17 Biomedical Beamline of the European Synchrotron Radiation Facility (ESRF). This innovative method is based on the fact that normal tissue can withstand high radiation doses in small volumes without any significant damage. The promising results obtained in the preclinical studies have paved the way to forthcoming clinical trials, which are currently in preparation. Highly accurate dose calculations at the treatment planning stage are required in this context. The aims of this study are the development and experimental benchmarking of a photon beam source model, which will be the core of the future MRT treatment planning system (TPS). Methods: The ID17 x-ray source was modeled by the synchrotron ray tracing code SHADOW. The Monte Carlo (MC) simulation code PENELOPE/PENEASY was employed to transport the photon beam from the source to the patient position through all the beamline components. The phase-space state variables of the particles reaching the patient position were used as an input to generate a photon beam model. Computed dose distributions in a homogeneous media were experimentally verified by using Gafchromic (R) VR films in a solid-water phantom. Benchmarking was split into two phases. First, the lateral dose profiles and the percentage depth-dose (PDD) curves in the broad beam configuration were considered. The acceptability criteria for radiotherapy dose computations recommended by international protocols such as the Technical Reports Series 430 (TRS 430) of the International Atomic Energy Agency (IAEA) were used. Second, the analogous dosimetric magnitudes in MRT irradiations, i.e., PDD of the central microbeam and the corresponding peak-to-valley dose ratios (PVDR) were evaluated and compared with MC calculations. Results: A full characterization of the ID17 Biomedical Beamline (ESRF) synchrotron x-ray source and the development of an accurate photon beam model were achieved in this work. Calculated and experimental dose distributions agreed to within the recommended acceptability criteria described in international codes of practice (TRS 430) for broad beam irradiations. The overall deviation in low gradient areas amounted to 2%-3%. The maximum distance-to-agreement in high gradient regions was lower than 0.7 mm. MC calculations also reproduced MRT experimental results within uncertainty bars. These results validate the photon beam model for its use inMRT radiation therapy calculations. Conclusions: The first MC synchrotron photon beam model for MRT irradiations that reproduces experimental dose distributions in homogeneous media has been developed. This beam model will constitute an essential component of the TPS calculation engine for patient dose computation in forthcoming MRT clinical trials. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3665768]
引用
收藏
页码:119 / 131
页数:13
相关论文
共 50 条
  • [1] Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Fernandez-Varea, J. M.
    Bravin, A.
    Prezado, Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15): : 4375 - 4388
  • [2] MONTE CARLO DOSIMETRY FOR THE CLINICAL TRIALS IN MICROBEAM RADIATION THERAPY
    Martinez-Rovira, I.
    Alonso, Y. Prezado
    Sempau, J.
    Fernandez-Varea, J. M.
    Bravin, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S71 - S72
  • [3] Photon-beam radiation therapy and Monte Carlo
    Siantar, CLH
    Garrett, D
    COMPUTING IN SCIENCE & ENGINEERING, 2000, 2 (05) : 31 - 38
  • [4] Commissioning and clinical validation of FRED: Monte Carlo on GPU for proton beam therapy
    Garbacz, M.
    Baran, J.
    Battistoni, G.
    Durante, M.
    Gajewski, J.
    Krah, N.
    Krzempek, K.
    Patera, V.
    Pawlik-Niedzwiecka, M.
    Rinaldi, I.
    Sas-Korczynska, B.
    Scifoni, E.
    Skrzypek, A.
    Schiavi, A.
    Tommasino, F.
    Rucinski, A.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1023 - S1024
  • [5] Development and commissioning of a Monte Carlo photon beam model for Varian Clinac 2100EX linear accelerator
    Mesbahi, A
    Reilly, AJ
    Thwaites, DI
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (06) : 656 - 662
  • [6] DEVELOPMENT OF A MONTE CARLO-BASED TREATMENT PLANNING SYSTEM FOR MICROBEAM RADIATION THERAPY
    Martinez-Rovira, I.
    Sempau, J.
    Bravin, A.
    Alonso, Y. Prezado
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S484 - S485
  • [7] Monte Carlo dose enhancement studies in microbeam radiation therapy
    Martinez-Rovira, I.
    Prezado, Y.
    MEDICAL PHYSICS, 2011, 38 (07) : 4430 - 4439
  • [8] Beam modeling and commissioning for Monte Carlo photon beam on an Elekta Versa HD LINAC
    Can, Sumeyra
    Karacetin, Didem
    Meric, Niyazi
    APPLIED RADIATION AND ISOTOPES, 2022, 180
  • [9] Development and commissioning of a multileaf collimator model in Monte Carlo dose calculations for intensity-modulated radiation therapy
    Jang, SY
    Vassiliev, ON
    Liu, HH
    Mohan, R
    Siebers, JV
    MEDICAL PHYSICS, 2006, 33 (03) : 770 - 781
  • [10] Modeling and commissioning of clinical photon beams for Monte Carlo treatment planning
    Jiang, SB
    Deng, J
    Li, JS
    Pawlicki, T
    Boyer, AL
    Ma, CM
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 434 - 436