Photon-beam radiation therapy and Monte Carlo

被引:1
|
作者
Siantar, CLH [1 ]
Garrett, D [1 ]
机构
[1] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
关键词
D O I
10.1109/5992.877388
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Because small variations in radiation doses can cause significant changes in clinical outcome, calculation accuracy is a major factor in the success or failure of a cancer treatment course. This article describes how stochastic, Monte Carlo radiation transport methods can predict radiation doses for cancer patients.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [1] Conformal photon-beam therapy with transverse magnetic fields: Monte Carlo study
    Li, XA
    Reiffel, L
    Chu, J
    Naqvi, S
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 3200 - 3202
  • [2] Conformal photon-beam therapy with transverse magnetic fields: A Monte Carlo study
    Li, XA
    Reiffel, L
    Chu, J
    Naqvi, S
    [J]. MEDICAL PHYSICS, 2001, 28 (02) : 127 - 133
  • [3] Clinical implementation of the PEREGRINE Monte Carlo dose calculation system for photon-beam therapy
    Siantar, CLH
    Bergstrom, PM
    Daly, TP
    Descalle, MA
    Garrett, D
    House, RK
    Knapp, DK
    May, S
    Patterson, RW
    Walling, RS
    Albright, N
    Verhey, L
    Weiczorek, D
    [J]. RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 199 - 203
  • [4] APPLICATIONS OF THE INVERSE MONTE-CARLO METHOD IN PHOTON-BEAM PHYSICS
    DUNN, WL
    BOFFI, VC
    OFOGHLUDHA, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (1-2): : 147 - 151
  • [5] Monte Carlo source model for megavoltage photon-beam radiotherapy: Photon source characteristics
    Fix, M
    Keall, P
    Libby, B
    Mohan, R
    Siebers, J
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1904 - 1904
  • [6] MONTE-CARLO CALCULATION OF THE PHOTON-BEAM SPECTRA OF A DUAL ENERGY LINAC
    BOYER, AL
    CASSADY, AE
    WANG, LL
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 452 - 452
  • [7] RELEVANCE OF RADIATION PENUMBRA IN HIGH-ENERGY PHOTON-BEAM THERAPY
    SASANE, JB
    IYER, PS
    [J]. STRAHLENTHERAPIE, 1981, 157 (10) : 658 - 661
  • [8] Investigation of photon beam output factors for conformal radiation therapy -: Monte Carlo simulations and measurements
    Haryanto, F
    Fippel, M
    Laub, W
    Dohm, O
    Nüsslin, F
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (11): : N133 - N143
  • [9] Application of Monte Carlo to proton beam radiation therapy
    Siebers, JV
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 1051 - 1056
  • [10] Development and commissioning of a Monte Carlo photon beam model for the forthcoming clinical trials in microbeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Prezado, Y.
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 119 - 131