Borehole prompt gamma neutron activation and comparison with Monte Carlo simulation using MCNP code - Borehole PGNAA experiment comparison with MCNP

被引:11
|
作者
Sohrabpour, M
Shahriari, M
Zarifian, V
Moghadam, KK
机构
[1] Atom Energy Org Iran, Gamma Irradiat Ctr, Tehran, Iran
[2] Amir Kabir Univ Technol, Dept Phys, Tehran, Iran
[3] Atom Energy Org Iran, Nucl Res Ctr, Tehran, Iran
关键词
D O I
10.1016/S0969-8043(98)00103-1
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A borehole experiment using prompt gamma neutron activation analysis has been performed in a large sample box having a volume of 1 m(3). Brine solutions having a salt concentration in the range of 0-10 wt% of sodium chloride has been used. Chlorine prompt gamma spectral response as a function of the salt concentrations have been obtained. A simulation of the above experiments has also been carried out using the MCNP4A Monte Carlo code. Comparison of the experimental spectral response versus the simulated MCNP4A data has produced excellent agreement. In view of the good benchmark data it is proposed that due to the inherent problems associated with the ordinary calibration procedures for the borehole logging tools, one could employ a combined calibration/simulation scheme to circumvent these difficulties and achieve more effective results. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [21] Coupling the MCNP Monte Carlo Code and the FISPACT Activation Code with Automatic Visualization of the Results of Simulations
    Bourauel, Peter
    Nabbi, Rahim
    Biel, Wolfgang
    Forrest, Robin
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2009, 54 (07): : 459 - +
  • [22] A benchmarked MCNP model of the in vivo detection of gadolinium by prompt gamma neutron activation analysis
    Grafe, J. L.
    McNeill, F. E.
    Byun, S. H.
    Chettle, D. R.
    Noseworthy, M. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (15): : 2451 - 2457
  • [23] Comparison of penumbra regions produced by ancient Gamma knife model C and Gamma ART 6000 using Monte Carlo MCNP6 simulation
    Banaee, Nooshin
    Asgari, Sepideh
    Nedaie, Hassan Ali
    APPLIED RADIATION AND ISOTOPES, 2018, 137 : 154 - 160
  • [24] The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
    J. G. Fantidis
    G. E. Nicolaou
    C. Potolias
    N. Vordos
    D. V. Bandekas
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 290 : 289 - 295
  • [25] The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
    Fantidis, J. G.
    Nicolaou, G. E.
    Potolias, C.
    Vordos, N.
    Bandekas, D. V.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 290 (02) : 289 - 295
  • [26] Calculation of thermal neutron self-shielding correction factors for aqueous bulk sample prompt gamma neutron activation analysis using the MCNP code
    Nasrabadi, M. N.
    Jalali, M.
    Mohammadi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (02): : 473 - 476
  • [27] CEARCPG: A Monte Carlo simulation code for normal and coincidence prompt-gamma-ray neutron activation analysis
    Han, Xiaogang
    Gardner, Robin P.
    Metwally, W. A.
    NUCLEAR SCIENCE AND ENGINEERING, 2006, 155 (01) : 143 - 153
  • [28] Monte Carlo calculations of thermal neutron capture in gadolinium: A comparison of GEANT4 and MCNP with measurements
    Enger, SA
    Af Rosenschld, PM
    Rezaei, A
    Lundqvist, H
    MEDICAL PHYSICS, 2006, 33 (02) : 337 - 341
  • [29] Monte Carlo modelling of pixel clusters in Timepix detectors using the MCNP code
    Solc, Jaroslav
    Jakubek, Jan
    Marek, Lukas
    Oancea, Cristina
    Pivec, Jiri
    Smoldasova, Jana
    Tesar, Jiri
    Vykydal, Zdenek
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 101 : 79 - 86
  • [30] Benchmark analysis of TRIGA mark II reactivity experiment using a continuous energy Monte Carlo code MCNP
    Matsumoto, T
    Hayakawa, N
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2000, 37 (12) : 1082 - 1087