The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron

被引:10
|
作者
Fantidis, J. G. [1 ]
Nicolaou, G. E. [2 ]
Potolias, C. [1 ]
Vordos, N. [1 ]
Bandekas, D. V. [1 ]
机构
[1] Kavala Inst Technol, Dept Elect Engn, Kavala, Greece
[2] Democritus Univ Thrace, Sch Engn, Lab Nucl Technol, GR-67100 Xanthi, Greece
关键词
Monte Carlo simulations; Gamma radioactivity; PGNAA; BODY-COMPOSITION; AM-BE; DETECTORS; SAMPLES; WATER;
D O I
10.1007/s10967-011-1315-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Prompt Gamma Ray Neutron Activation Analysis (PGNAA) system, incorporating an isotopic neutron source has been simulated using the MCNPX Monte Carlo code. In order to improve the signal to noise ratio different collimators and a filter were placed between the neutron source and the object. The effect of the positioning of the neutron beam and the detector relative to the object has been studied. In this work the optimisation procedure is demonstrated for boron. Monte Carlo calculations were carried out to compare the performance of the proposed PGNAA system using four different neutron sources (Am-241/Be, Cf-252, Am-241/B, and DT neutron generator). Among the different systems the Cf-252 neutron based PGNAA system has the best performance.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 50 条
  • [1] The comparison of four neutron sources for Prompt Gamma Neutron Activation Analysis (PGNAA) in vivo detections of boron
    J. G. Fantidis
    G. E. Nicolaou
    C. Potolias
    N. Vordos
    D. V. Bandekas
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2011, 290 : 289 - 295
  • [2] The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)
    Pinault, Jean-Louis
    Solis, Jose
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (07): : 1139 - 1148
  • [3] Comparison of transportable neutron sources for quantitative elemental analysis using prompt gamma neutron activation technique
    Udupi, Ashwini
    Shetty, Pramoda Kumara
    Panikkath, Priyada
    Sarkar, Pradip Kumar
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 180
  • [4] Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source
    Ş. Turhan
    H. Yücel
    A. Demirbaş
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2005, 262 (3) : 661 - 664
  • [5] Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source
    Turhan, S
    Yücel, H
    Demirbas, A
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 262 (03) : 661 - 664
  • [6] Prompt gamma neutron activation analysis of boron with a 241Am-Be neutron source
    Ş. Turhan
    H. Yücel
    A. Demirbaş
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2004, 262 : 661 - 667
  • [7] Design, construction, and characterization of a Prompt Gamma Neutron Activation Analysis (PGNAA) system at Isfahan MNSR
    Dastjerdi, M. H. Choopan
    Mokhtari, J.
    Toghyani, M.
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (12) : 4329 - 4334
  • [8] Monte Carlo calculations and neutron spectrometry in quantitative prompt gamma neutron activation analysis (PGNAA) of bulk samples using an isotopic neutron source
    N. M. Spyrou
    J. B. Awotwi-Pratt
    A. M. Williams
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2004, 259 : 287 - 291
  • [9] Monte Carlo calculations and neutron spectrometry in quantitative prompt gamma neutron activation analysis (PGNAA) of bulk samples using an isotopic neutron source
    Spyrou, NM
    Awotwi-Pratt, JB
    Williams, AM
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 259 (02) : 287 - 291
  • [10] In vivo prompt gamma neutron activation analysis of cadmium in the kidney and liver
    Grinyer, J
    Byun, SH
    Chettle, DR
    [J]. APPLIED RADIATION AND ISOTOPES, 2005, 63 (04) : 475 - 479