Borehole prompt gamma neutron activation and comparison with Monte Carlo simulation using MCNP code - Borehole PGNAA experiment comparison with MCNP

被引:11
|
作者
Sohrabpour, M
Shahriari, M
Zarifian, V
Moghadam, KK
机构
[1] Atom Energy Org Iran, Gamma Irradiat Ctr, Tehran, Iran
[2] Amir Kabir Univ Technol, Dept Phys, Tehran, Iran
[3] Atom Energy Org Iran, Nucl Res Ctr, Tehran, Iran
关键词
D O I
10.1016/S0969-8043(98)00103-1
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A borehole experiment using prompt gamma neutron activation analysis has been performed in a large sample box having a volume of 1 m(3). Brine solutions having a salt concentration in the range of 0-10 wt% of sodium chloride has been used. Chlorine prompt gamma spectral response as a function of the salt concentrations have been obtained. A simulation of the above experiments has also been carried out using the MCNP4A Monte Carlo code. Comparison of the experimental spectral response versus the simulated MCNP4A data has produced excellent agreement. In view of the good benchmark data it is proposed that due to the inherent problems associated with the ordinary calibration procedures for the borehole logging tools, one could employ a combined calibration/simulation scheme to circumvent these difficulties and achieve more effective results. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [31] The application of prompt-gamma neutron activation analysis to borehole logging for coal
    Borsaru, M
    Biggs, M
    Nichols, W
    Bos, F
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (02) : 335 - 343
  • [32] Monte Carlo analysis of HDPE using PHITS and MCNP for neutron shielding applications
    Unagar, Vishal
    Makwana, Rajnikant
    Barala, S. S.
    Meena, D.
    Gupta, S. K.
    Kavun, Y.
    Mehta, M.
    Vashi, V.
    Singh, R. K.
    Chauhan, R.
    Mukherjee, S. K.
    Singh, N. L.
    Katovsky, K.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (11) : 5457 - 5464
  • [33] Comparison of a laboratory spectrum of Eu-152 with results of simulation using the MCNP code
    Rodenas, J.
    Gallardo, S.
    Ortiz, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 303 - 305
  • [34] Monte Carlo validation of dose mapping for the Tunisian Gamma Irradiation Facility using the MCNP6 code
    Dridi, W.
    Daoudi, M.
    Farah, K.
    Hosni, F.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 173
  • [35] Optimization of HANARO cold neutron induced prompt gamma activation analysis system by using Monte Carlo code
    Sy Minh Tuan Hoang
    Gwang Min Sun
    Jong Hwa Moon
    Yong Sam Chung
    Byung Gun Park
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 967 - 973
  • [36] Optimization of HANARO cold neutron induced prompt gamma activation analysis system by using Monte Carlo code
    Sy Minh Tuan Hoang
    Sun, Gwang Min
    Moon, Jong Hwa
    Chung, Yong Sam
    Park, Byung Gun
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (02) : 967 - 973
  • [37] The Monte Carlo code CEARCPG for coincidence prompt gamma-ray neutron activation analysis
    Han, Xiaogang
    Gardner, Robin P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 320 - 325
  • [38] The comparison of two MCNP models used for prompt gamma in vivo detection of cadmium and mercury
    Atanackovic, J.
    Grinyer, J.
    Chettle, D. R.
    Byun, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 169 - 174
  • [39] Measurement of deuterium concentration in heavy water utilizing prompt gamma neutron activation analysis (PGNAA) in comparison with MCNPX simulation results
    Salahi, Saeed
    Dorostkar, Mahdieh Mokhtari
    Saray, Akbar Abdi
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (11) : 4231 - 4235
  • [40] Monte Carlo calculation for the development of a BNCT neutron source (1 eV-10 KeV) using MCNP code
    El Moussaoui, F.
    El Bardouni, T.
    Azahra, M.
    Kamili, A.
    Boukhal, H.
    CANCER RADIOTHERAPIE, 2008, 12 (05): : 360 - 364