Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators

被引:17
|
作者
Theuns, D [1 ]
Klootwijk, AP [1 ]
Kimman, GP [1 ]
Szili-Török, T [1 ]
Roelandt, JRTC [1 ]
Jordaens, L [1 ]
机构
[1] Thoraxctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
来源
EUROPACE | 2001年 / 3卷 / 03期
关键词
implantable defibrillator; dual chamber sensing; atrial fibrillation; inappropriate ICD therapy; detection criteria;
D O I
10.1053/eupc.2001.0171
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Inappropriate therapy, due to poor discrimination of supraventricular. tachycardia (SVT) from ventricular tachycardia (VT) remains a major problem in patients with an implantable cardioverter defibrillator (ICD). Theoretically, the addition of atrial sensing in discrimination algorithms should improve this differentiation. The aim of the study is to evaluate the performance of a new tachycardia discrimination algorithm, SMART Detection (TM) Methods and Results Twenty-six patients received a non-thoracotomy ICD system (Phylax AV, Biotronik, Germany). All documented spontaneous arrhythmia episodes were analyzed. During a mean follow-up of 8 months, a total number of 139 events with stored electrograms were recorded in 12 patients. The final diagnosis was ventricular fibrillation (VF) or polymorphic VT (n=20), monomorphic VT (n=69), SVT (n=26), other. ventricular arrhythmia (n=3) and T wave oversensing (n=21). In 6 episodes a dual tachycardia was present. Considering SVT episodes, inappropriate therapy occurred in 2 cases of atrial flutter due to stable ventricular rate (< 30 ms), 1 case of atrial tachycardia and 2 cases of sinus tachycardia due to a sudden onset Conclusion With the SMART Detection (TM) algorithm, discrimination of VT from SVT achieved a sensitivity of 100%, with an accuracy of 95(.)6% for all ventricular arrhythmias. Tn the case of SVT, the algorithm appropriately detected and inhibited therapy in 88% of atrial fibrillation. (C) 2000 The European Society of Cardiology.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [41] Usefulness of dual chamber detection algorithm in ICD. Initial clinical experience.
    Sadoul, NN
    Chauvin, MM
    Leenhardt, AA
    Henry, CC
    Iscolo, NN
    Levy, SS
    CIRCULATION, 1996, 94 (08) : 1872 - 1872
  • [42] Clinical experience with downsized lower energy output implantable cardioverter defibrillators
    Boriani, G
    Frabetti, L
    Biffi, M
    Sallusti, L
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1998, 66 (03) : 261 - 266
  • [43] Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection -: Results and technical considerations
    Wilkoff, BL
    Kühlkamp, V
    Volosin, K
    Ellenbogen, K
    Waldecker, B
    Kacet, S
    Gillberg, JM
    DeSouza, CM
    CIRCULATION, 2001, 103 (03) : 381 - 386
  • [44] Importance of the atrial channel for ventricular arrhythmia therapy in the dual chamber implantable cardioverter defibrillator
    Dijkman, B
    Wellens, HJJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (12) : 1309 - 1319
  • [45] Comparison of therapy detection times between implantable cardioverter defibrillators with standard dual- and single-chamber pacing
    Capucci, A
    Villani, GQ
    Groppi, F
    Aschieri, D
    Hull, M
    Kuehl, M
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (04) : 329 - 333
  • [46] Comparison of Therapy Detection Times Between Implantable Cardioverter Defibrillators with Standard Dual- and Single-Chamber Pacing
    Alessandro Capucci
    G. Q. Villani
    F. Groppi
    D. Aschieri
    M. Hull
    M. Kuehl
    Journal of Interventional Cardiac Electrophysiology, 1999, 3 : 329 - 333
  • [47] Implantable cardiac arrhythmia devices - Part II: Implantable cardioverter defibrillators and implantable loop recorders
    Kusumoto, Fred
    Goldschlager, Nora
    CLINICAL CARDIOLOGY, 2006, 29 (06) : 237 - 242
  • [48] Initial experience with a new discrimination algorithm in dual chamber ICDs
    Theuns, D
    Szili-Török, T
    Kimman, GJ
    Klootwijk, APJ
    Jordaens, L
    NEW TRENDS IN ELECTROCARDIOLOGY, 2000, : 155 - 160
  • [49] Optimization of right ventricular pacing among patients with dual-chamber implantable cardioverter defibrillators
    Olshansky, B
    Day, J
    McGuire, M
    Stolen, K
    Pratt, T
    JOURNAL OF CARDIAC FAILURE, 2004, 10 (04) : S66 - S66
  • [50] Accuracy of arrhythmia discrimination algorithms: First results from a prospective, randomized trial of single versus dual chamber implantable cardioverter defibrillators (PINAPP)
    Theuns, DA
    Klootwijk, PJ
    Jordaens, LJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 139A - 139A