Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators

被引:17
|
作者
Theuns, D [1 ]
Klootwijk, AP [1 ]
Kimman, GP [1 ]
Szili-Török, T [1 ]
Roelandt, JRTC [1 ]
Jordaens, L [1 ]
机构
[1] Thoraxctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
来源
EUROPACE | 2001年 / 3卷 / 03期
关键词
implantable defibrillator; dual chamber sensing; atrial fibrillation; inappropriate ICD therapy; detection criteria;
D O I
10.1053/eupc.2001.0171
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Inappropriate therapy, due to poor discrimination of supraventricular. tachycardia (SVT) from ventricular tachycardia (VT) remains a major problem in patients with an implantable cardioverter defibrillator (ICD). Theoretically, the addition of atrial sensing in discrimination algorithms should improve this differentiation. The aim of the study is to evaluate the performance of a new tachycardia discrimination algorithm, SMART Detection (TM) Methods and Results Twenty-six patients received a non-thoracotomy ICD system (Phylax AV, Biotronik, Germany). All documented spontaneous arrhythmia episodes were analyzed. During a mean follow-up of 8 months, a total number of 139 events with stored electrograms were recorded in 12 patients. The final diagnosis was ventricular fibrillation (VF) or polymorphic VT (n=20), monomorphic VT (n=69), SVT (n=26), other. ventricular arrhythmia (n=3) and T wave oversensing (n=21). In 6 episodes a dual tachycardia was present. Considering SVT episodes, inappropriate therapy occurred in 2 cases of atrial flutter due to stable ventricular rate (< 30 ms), 1 case of atrial tachycardia and 2 cases of sinus tachycardia due to a sudden onset Conclusion With the SMART Detection (TM) algorithm, discrimination of VT from SVT achieved a sensitivity of 100%, with an accuracy of 95(.)6% for all ventricular arrhythmias. Tn the case of SVT, the algorithm appropriately detected and inhibited therapy in 88% of atrial fibrillation. (C) 2000 The European Society of Cardiology.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [31] Renal Denervation for Ventricular Arrhythmia in Patients with Implantable Cardioverter Defibrillators Experience in Asian Population
    Jiang, Zhixin
    Zhou, Xiujuan
    Chen, Chun
    Wang, Yung
    Fang, Ping
    Geng, Jie
    Zhang, Gang
    Shan, Qijun
    INTERNATIONAL HEART JOURNAL, 2018, 59 (02) : 328 - 332
  • [32] Initial experience with an implantable cardioverter defibrillator providing dual chamber rate adaptive pacing and sensing
    Auricchio, A
    Klein, H
    Kühl, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 294A - 294A
  • [33] Detection algorithms in implantable cardioverter defibrillators
    Univ of Michigan, Ann Arbor, United States
    Proc IEEE, 3 (428-445):
  • [34] Clinical experience with a dual-chamber implantable cardioverter defibrillator to treat atrial tachyarrhythmias
    Gold, MR
    Sulke, N
    Schwartzman, DS
    Mehra, R
    Euler, DE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (11) : 1247 - 1253
  • [35] Detection algorithms in implantable cardioverter defibrillators
    Jenkins, JM
    Caswell, SA
    PROCEEDINGS OF THE IEEE, 1996, 84 (03) : 428 - 445
  • [36] Life-threatening ventricular arrhythmia detection challenge in implantable cardioverter-defibrillators
    Jia, Zhenge
    Li, Dawei
    Xu, Xiaowei
    Li, Na
    Hong, Feng
    Ping, Lichuan
    Shi, Yiyu
    NATURE MACHINE INTELLIGENCE, 2023, 5 (05) : 554 - 555
  • [37] Ventricular tachycardia with retrograde conduction in patients with dual-chamber implantable cardioverter/defibrillators
    Schuchert, A
    Möx, B
    Jordeans, L
    Merkely, B
    Gill, J
    Meinertz, T
    EUROPEAN HEART JOURNAL, 2001, 22 : 564 - 564
  • [38] Should all implantable cardioverter defibrillators for ventricular arrhythmias be dual-chamber devices?
    Lee K.L.
    Lau C.-P.
    Current Cardiology Reports, 2001, 3 (6) : 447 - 450
  • [39] Rhythm discrimination by rate branch and QRS morphology in dual chamber implantable cardioverter defibrillators
    Boriani, G
    Biffi, M
    Dall'Acqua, A
    Martignani, C
    Frabetti, L
    Zannoli, R
    Branzi, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (01): : 466 - 470
  • [40] Clinical Experience of Subcutaneous and Transvenous Implantable Cardioverter Defibrillators in Children and Teenagers
    Pettit, Stephen J.
    Mclean, Andrew
    Colquhoun, Ian
    Connelly, Derek
    McLeod, Karen
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (12): : 1532 - 1535