Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators

被引:17
|
作者
Theuns, D [1 ]
Klootwijk, AP [1 ]
Kimman, GP [1 ]
Szili-Török, T [1 ]
Roelandt, JRTC [1 ]
Jordaens, L [1 ]
机构
[1] Thoraxctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
来源
EUROPACE | 2001年 / 3卷 / 03期
关键词
implantable defibrillator; dual chamber sensing; atrial fibrillation; inappropriate ICD therapy; detection criteria;
D O I
10.1053/eupc.2001.0171
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Inappropriate therapy, due to poor discrimination of supraventricular. tachycardia (SVT) from ventricular tachycardia (VT) remains a major problem in patients with an implantable cardioverter defibrillator (ICD). Theoretically, the addition of atrial sensing in discrimination algorithms should improve this differentiation. The aim of the study is to evaluate the performance of a new tachycardia discrimination algorithm, SMART Detection (TM) Methods and Results Twenty-six patients received a non-thoracotomy ICD system (Phylax AV, Biotronik, Germany). All documented spontaneous arrhythmia episodes were analyzed. During a mean follow-up of 8 months, a total number of 139 events with stored electrograms were recorded in 12 patients. The final diagnosis was ventricular fibrillation (VF) or polymorphic VT (n=20), monomorphic VT (n=69), SVT (n=26), other. ventricular arrhythmia (n=3) and T wave oversensing (n=21). In 6 episodes a dual tachycardia was present. Considering SVT episodes, inappropriate therapy occurred in 2 cases of atrial flutter due to stable ventricular rate (< 30 ms), 1 case of atrial tachycardia and 2 cases of sinus tachycardia due to a sudden onset Conclusion With the SMART Detection (TM) algorithm, discrimination of VT from SVT achieved a sensitivity of 100%, with an accuracy of 95(.)6% for all ventricular arrhythmias. Tn the case of SVT, the algorithm appropriately detected and inhibited therapy in 88% of atrial fibrillation. (C) 2000 The European Society of Cardiology.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [21] A randomised study of single and dual chamber implantable cardioverter-defibrillators in detection of atrial tachyarrhythmias
    Theuns, DAMJ
    Klootwijk, APJ
    Goedhart, DM
    Scholten, MF
    Thornton, AS
    Jordaens, LJ
    EUROPEAN HEART JOURNAL, 2004, 25 : 173 - 173
  • [22] CLINICAL-EXPERIENCE IN PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS
    TSUJI, H
    SHAHIAN, DM
    VENDITTI, FJ
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1991, 55 (07): : 669 - 675
  • [23] Dual-Chamber Implantable Cardioverter-Defibrillators for Nonpacing Indications
    Redberg, Rita F.
    ARCHIVES OF INTERNAL MEDICINE, 2012, 172 (08) : 641 - 641
  • [24] Development of detection algorithm of fatal arrhythmia for a new implantable cardioverter defibrillator
    Yoshizawa, Makoto
    Inagaki, Masashi
    Uemura, Kazunori
    Sugimachi, Masaru
    Sunagawa, Kenji
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3909 - 3912
  • [25] First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator - Advantages and complications
    Sticherling, C
    Schaumann, A
    Klingenheben, T
    Hohnloser, SH
    EUROPACE, 1999, 1 (02): : 96 - 102
  • [26] Arrhythmia classification with the first dual-chamber implantable cardioverter defibrillator
    Jung, W
    Esmailzadeh, B
    Nitzsche, R
    Wolpert, C
    Luderitz, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 7201 - 7201
  • [27] Possible benefits of dual-chamber implantable cardioverter-defibrillators in reducing inadequate therapy compared to conventional single-chamber implantable cardioverter-defibrillators: a clinical randomised study
    Deisenhofer, I
    Kolb, C
    Schreieck, J
    Karch, MR
    Zrenner, B
    Schmitt, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 470 - 470
  • [28] Life-threatening ventricular arrhythmia detection challenge in implantable cardioverter–defibrillators
    Zhenge Jia
    Dawei Li
    Xiaowei Xu
    Na Li
    Feng Hong
    Lichuan Ping
    Yiyu Shi
    Nature Machine Intelligence, 2023, 5 : 554 - 555
  • [29] Algorithms for better arrhythmia discrimination in implantable cardioverter defibrillators
    Schimpf R.
    Wolpert C.
    Lüderitz B.
    Current Cardiology Reports, 2001, 3 (6) : 467 - 472
  • [30] SINGLE VERSUS DUAL CHAMBER IMPLANTABLE CARDIOVERTER DEFIBRILLATORS: ARE SINGLE CHAMBER DEVICES REALLY OBSOLETE?
    Mohammed, Akif A.
    Bhat, Pradeep K.
    Unsdorfer, Kyle
    Costantini, Ottorino
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E15 - E15