Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators

被引:17
|
作者
Theuns, D [1 ]
Klootwijk, AP [1 ]
Kimman, GP [1 ]
Szili-Török, T [1 ]
Roelandt, JRTC [1 ]
Jordaens, L [1 ]
机构
[1] Thoraxctr, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
来源
EUROPACE | 2001年 / 3卷 / 03期
关键词
implantable defibrillator; dual chamber sensing; atrial fibrillation; inappropriate ICD therapy; detection criteria;
D O I
10.1053/eupc.2001.0171
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Inappropriate therapy, due to poor discrimination of supraventricular. tachycardia (SVT) from ventricular tachycardia (VT) remains a major problem in patients with an implantable cardioverter defibrillator (ICD). Theoretically, the addition of atrial sensing in discrimination algorithms should improve this differentiation. The aim of the study is to evaluate the performance of a new tachycardia discrimination algorithm, SMART Detection (TM) Methods and Results Twenty-six patients received a non-thoracotomy ICD system (Phylax AV, Biotronik, Germany). All documented spontaneous arrhythmia episodes were analyzed. During a mean follow-up of 8 months, a total number of 139 events with stored electrograms were recorded in 12 patients. The final diagnosis was ventricular fibrillation (VF) or polymorphic VT (n=20), monomorphic VT (n=69), SVT (n=26), other. ventricular arrhythmia (n=3) and T wave oversensing (n=21). In 6 episodes a dual tachycardia was present. Considering SVT episodes, inappropriate therapy occurred in 2 cases of atrial flutter due to stable ventricular rate (< 30 ms), 1 case of atrial tachycardia and 2 cases of sinus tachycardia due to a sudden onset Conclusion With the SMART Detection (TM) algorithm, discrimination of VT from SVT achieved a sensitivity of 100%, with an accuracy of 95(.)6% for all ventricular arrhythmias. Tn the case of SVT, the algorithm appropriately detected and inhibited therapy in 88% of atrial fibrillation. (C) 2000 The European Society of Cardiology.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 50 条
  • [1] Arrhythmia detection by dual-chamber implantable cardioverter defibrillators -: A review of current algorithms
    Aliot, E
    Nitzsché, R
    Ripart, A
    EUROPACE, 2004, 6 (04): : 273 - 286
  • [2] Dual chamber arrhythmia detection in the implantable cardioverter defibrillator
    Dijkman, B
    Wellens, HJJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (10) : 1105 - 1115
  • [3] Arrhythmia Detection in Single- and Dual-Chamber Implantable Cardioverter Defibrillators: The More Leads, the Better?
    Francia, Pietro
    Balla, Cristina
    Uccellini, Arianna
    Cappato, Riccardo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (09) : 1077 - 1082
  • [4] Advances in dual chamber implantable cardioverter/defibrillators
    Elliott, L
    Gilkerson, J
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1998, 11 (03) : 187 - 196
  • [5] Initial clinical experience with the first dual-chamber implantable cardioverter defibrillator
    Lavergne, TT
    Ritter, PP
    Nitzsche, RR
    Saoudi, NN
    Kacet, SS
    Ollitrault, JJ
    Daubert, JCJC
    Lacroix, DD
    Poly, HH
    CIRCULATION, 1996, 94 (08) : 3287 - 3287
  • [6] Initial clinical experience with a dual chamber rate responsive implantable cardioverter defibrillator
    Luceri, RM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1986 - 1988
  • [7] Initial experience in the remote monitoring of implantable cardioverter defibrillators
    Affolter, J. T.
    Redfem, C.
    Patel, J. C.
    Lewis, A.
    Broadhurst, P. A.
    SCOTTISH MEDICAL JOURNAL, 2008, 53 (02) : 57 - 57
  • [8] Prevalence of sensing abnormalities in dual chamber implantable cardioverter defibrillators
    Saeed, M
    Jin, A
    Pontone, G
    Higgins, S
    Gold, M
    Harari, D
    Nunley, S
    Link, MS
    Homoud, MK
    Estes, NAM
    Wang, PJ
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2003, 8 (03) : 219 - 226
  • [9] Improved arrhythmia classification with a new pectoral dual chamber implantable cardioverter defibrillator
    Jung, W
    Spehl, S
    Wolpert, C
    Esmailzadeh, B
    Schumacher, B
    Lewalter, T
    CIRCULATION, 1997, 96 (08) : 3238 - 3238
  • [10] Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator system
    Schoels, W
    Swerdlow, CD
    Jung, W
    Stein, KM
    Seidl, K
    Haffajee, CJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (05) : 521 - 528