Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection

被引:1
|
作者
Wenz, Hans-Juergen [1 ]
Hertrampf, Katrin [2 ]
机构
[1] Univ Hosp Schleswig Holstein, Clin Prosthodont Propaedeut & Dent Mat, D-24105 Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Clin Oral & Maxillofacial Surg, D-24105 Kiel, Germany
关键词
dental implants; impression materials; impression technique; transfer coping;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the deviations of the implant positions of both impressions and casts using different impression materials and techniques. Furthermore, the existence of a correlation between the deviations of the impression and those of the cast was investigated. Materials and Methods: A reference model was fabricated with 5 Frialit-2 implants parallel to each other. In a standardized experimental setting, 5 stone casts were produced with 5 different techniques using polyether (A) or polyvinyl siloxane (B through E). In 3 groups, a direct technique was used with a medium-viscosity material or a putty-tray material in combination with a light-viscosity syringe material (A to C). In 2 groups, an indirect technique (either 1-step [group D] or 2-step [group E] was used with a putty-tray material in combination with a light-viscosity syringe material. The center-to-center distances were measured for impressions and casts in the horizontal plane using a computer-aided microscope, and the relative and absolute deviations compared to the reference model were calculated. Analysis of variance followed by the post-hoc Scheffe test (parametric data) or the Kruskal-Wallis test followed by pair-wise Mann-Whitney tests (nonparametric data) were used for statistical analyses. Deviations of impressions were compared with their respective casts using paired t tests and the Pearson correlation coefficient. Results: No significant differences for the relative deviations were found for impressions (-5 to -8 mu m) or casts (+7 to +16 mu m). Group E produced significantly higher absolute deviations for impressions (38 mu m) and casts (39 mu m) compared to the other groups (11 to 18 mu m and 17 to 23 mu m, respectively). A significant correlation between deviation of the impression and its respective cast was found for every group (r = 0.40 to 0.80) except group D. Conclusions: The distortions in the horizontal plane of the casts obtained from the impression techniques of groups A to D would probably not affect the clinical fit of implant-retained superstructures. Because of the high variation of deviations (-113 to +124 mu m), the 2-step technique cannot be recommended. The method to measure both impression and cast provided a better understanding of how inaccuracies are caused.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 49 条
  • [31] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    [J]. JOURNAL OF DENTISTRY, 2022, 126
  • [32] Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study
    Papaspyridakos, Panos
    Benic, Goran I.
    Hogsett, Virginia Lea
    White, George Shelby
    Lal, Kunal
    Gallucci, German O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (06) : 676 - 681
  • [33] A COMPARATIVE-ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN-GAUGE
    HAN, ET
    KIM, YS
    [J]. JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 995 - 995
  • [34] A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system
    Burawi, G
    Houston, F
    Byrne, D
    Claffey, N
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (01): : 68 - 75
  • [35] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    [J]. JOURNAL OF DENTISTRY, 2024, 146
  • [36] The Accuracy of Casts Obtained Using Different Impression Techniques and Impression Materials in Combined Parallel and Angulated Implants: An In Vitro Study
    Menaga, V
    Chirom, Babina
    Gunadhar, Kangjam
    Priyadarshini, Shamurailatpam
    Nongthombam, Rajesh S.
    Manikandan, P.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [37] The Effect of Impression Technique and Implant Angulation on the Impression Accuracy of External- and Internal-Connection Implants (vol 27, pg 1422, 2012)
    Mpikos, Pavlos
    Kafantaris, Nikolaos
    Tortopidis, Dimitrios
    Galanis, Christos
    Kaisarlis, George
    Koidis, Petros
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 43 - 43
  • [38] Evaluation of Accuracy of Complete-Arch Multiple-Unit Abutment-Level Dental Implant Impressions Using Different Impression and Splinting Materials
    Buzayan, Muaiyed
    Baig, Mirza Rustum
    Yunus, Norsiah
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : 1512 - 1520
  • [39] Comparison of Different Impression Techniques When Using the All-on-Four Implant Treatment Protocol
    Siadat, Hakimeh
    Alikhasi, Marzieh
    Beyabanaki, Elaheh
    Rahimian, Susan
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (03) : 265 - 270
  • [40] The Effect of Different Screw-Tightening Techniques on the Stress Generated on an Internal-Connection Implant Superstructure
    Choi, Jung-Han
    Lim, Young-Jun
    Kim, Chang-Whe
    Kim, Myung-Joo
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (06) : 1045 - 1053