Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study

被引:92
|
作者
Papaspyridakos, Panos [1 ,2 ]
Benic, Goran I. [1 ,3 ]
Hogsett, Virginia Lea [1 ]
White, George Shelby [2 ]
Lal, Kunal [2 ]
Gallucci, German O. [1 ]
机构
[1] Harvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
[2] Columbia Univ, Div Prosthodont, Coll Dent Med, New York, NY USA
[3] Univ Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
关键词
accuracy; fully edentulous; implant casts; implant impressions; optical scanning; IN-VITRO; OSSEOINTEGRATED IMPLANTS; SUPPORTED PROSTHESIS; ZIRCONIA PROSTHESIS; FIT; FRAMEWORKS; SUPERSTRUCTURES; REHABILITATION; COMPONENTS; PRECISION;
D O I
10.1111/j.1600-0501.2011.02219.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The accuracy of implant casts generated with various impression techniques was mainly investigated in vitro resulting in limited clinical data. Purpose: (1) To compare the three-dimensional (3-D) accuracy of splinted and non-splinted impression techniques to the control casts (verification jigs) that had been used for actual patient treatment; and (2) to determine the maximum level of clinically undetectable misfit. The null hypothesis was that there would be no significant difference in the accuracy of casts generated with different impression techniques. Materials and methods: The implant casts used for the prosthetic rehabilitation of 12 edentulous jaws with CAD/CAM zirconia, implant-fixed complete dental prosthesis (IFCDP) were included in this study. Intraoral acrylic jigs were used to fabricate index casts. Splinted and non-splinted, open-tray techniques were used to generate two casts. Optical scanning acquisition of the x-coordinates, y-coordinates and z-coordinates of the implant positions for each individual cast was performed. The best fit algorithm was used with computer software to superimpose the scanning datasets. Group I (n=12) included casts from the splinted impression technique vs. acrylic jig casts, and group II (n=12) included casts from non-splinted technique vs. jig casts. Results: The paired t-test and Wilcoxon's signed ranks test were used to compare the 3-D discrepancies within and between groups I (splinted vs. jig) and II (non-splinted vs. jig), respectively. Significant difference was found at the x-axis, y-axis and 3-D between groups I and II (P<0.05), but not in the vertical z-axis (P>0.05). Within subject, global 3-D discrepancies between groups I and II were significantly different (P<0.05), corroborated by in vivo observations of clinical fit. Implant position in the arch affected the 3-D accuracy of casts for both anterior and posterior implants (P<0.05). Conclusion: The splinted technique generated more accurate master casts than the non-splinted technique for one-piece IFCDPs in edentulous jaws and the null hypothesis was rejected. These clinical implications demonstrate improved accuracy of splinted impression techniques compared with the non-splinted technique. For the external connection, the implant system used in this study, a 3-D misfit ranging from 59 to 72 mu m, may be considered the maximum discrepancy resulting in an acceptable clinical fit with one-piece IFCDPs.
引用
收藏
页码:676 / 681
页数:6
相关论文
共 24 条
  • [1] Efficacy of Splinted and Non-splinted Direct Impression Techniques for Completely Edentulous Patients Requiring Implant Supported Prostheses- A Systematic Review
    Wadhwani, Varun
    Nallasway, Deepak
    Sivaswamy, Vinay
    Shah, Khushali K.
    Maiti, Subhabrata
    [J]. JOURNAL OF POPULATION THERAPEUTICS AND CLINICAL PHARMACOLOGY, 2023, 30 (10): : E292 - E308
  • [2] Effect of Splinted and Nonsplinted Impression Techniques on the Accuracy of Fit of Fixed Implant Prostheses in Edentulous Patients: A Comparative Study
    Papaspyridakos, Panos
    Lal, Kunal
    White, George Shelby
    Weber, Hans-Peter
    Gallucci, German O.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1267 - 1272
  • [3] Comparison of stress distribution in partially and completely edentulous mandibles around splinted and non-splinted implant prostheses: A finite element study
    Ozeki, K.
    Nishio, H.
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 31 (01) : 19 - 33
  • [4] Accuracy of implant impression splinted techniques: Effect of splinting material
    Assif, D
    Nissan, J
    Varsano, I
    Singer, A
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (06) : 885 - 888
  • [5] Effect of Implant Angulation and Depth on the Accuracy of Casts Using the Open Tray Splinted Impression Technique
    Taduri, Thanmai
    Mathur, Somil
    Upadhyay, Snehal
    Patel, Khushali
    Shah, Meena
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (06) : 447 - 454
  • [6] Accuracy of Milled Titanium Frameworks Constructed with Direct Scanning and Splinted Impression Techniques
    Badwal, Amandeep Singh
    Dudley, James
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (03) : 236 - 238
  • [7] A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system
    Burawi, G
    Houston, F
    Byrne, D
    Claffey, N
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (01): : 68 - 75
  • [8] Clinical, Radiographic Peri-Implant Parameters and Patient Satisfaction with Splinted and Non-splinted Short Dental Implants in the Maxillary Premolar-Molar Region: A Long-Term Retrospective Clinical Study
    AlHamdan, Eman M.
    Alsahhaf, Abdulaziz
    Alzahrani, Khaled M.
    Vohra, Fahim
    Abduljabbar, Tariq
    [J]. ORAL HEALTH & PREVENTIVE DENTISTRY, 2023, 21 (01) : 291 - 296
  • [9] Effects of crown-to-implant ratio on marginal bone level and bone density in non-splinted single implants: a cross-sectional study
    Ziyuan Chen
    Weiting Li
    Peng Li
    [J]. BMC Oral Health, 23
  • [10] Effects of crown-to-implant ratio on marginal bone level and bone density in non-splinted single implants: a cross-sectional study
    Chen, Ziyuan
    Li, Weiting
    Li, Peng
    [J]. BMC ORAL HEALTH, 2023, 23 (01)