Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection

被引:1
|
作者
Wenz, Hans-Juergen [1 ]
Hertrampf, Katrin [2 ]
机构
[1] Univ Hosp Schleswig Holstein, Clin Prosthodont Propaedeut & Dent Mat, D-24105 Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Clin Oral & Maxillofacial Surg, D-24105 Kiel, Germany
关键词
dental implants; impression materials; impression technique; transfer coping;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the deviations of the implant positions of both impressions and casts using different impression materials and techniques. Furthermore, the existence of a correlation between the deviations of the impression and those of the cast was investigated. Materials and Methods: A reference model was fabricated with 5 Frialit-2 implants parallel to each other. In a standardized experimental setting, 5 stone casts were produced with 5 different techniques using polyether (A) or polyvinyl siloxane (B through E). In 3 groups, a direct technique was used with a medium-viscosity material or a putty-tray material in combination with a light-viscosity syringe material (A to C). In 2 groups, an indirect technique (either 1-step [group D] or 2-step [group E] was used with a putty-tray material in combination with a light-viscosity syringe material. The center-to-center distances were measured for impressions and casts in the horizontal plane using a computer-aided microscope, and the relative and absolute deviations compared to the reference model were calculated. Analysis of variance followed by the post-hoc Scheffe test (parametric data) or the Kruskal-Wallis test followed by pair-wise Mann-Whitney tests (nonparametric data) were used for statistical analyses. Deviations of impressions were compared with their respective casts using paired t tests and the Pearson correlation coefficient. Results: No significant differences for the relative deviations were found for impressions (-5 to -8 mu m) or casts (+7 to +16 mu m). Group E produced significantly higher absolute deviations for impressions (38 mu m) and casts (39 mu m) compared to the other groups (11 to 18 mu m and 17 to 23 mu m, respectively). A significant correlation between deviation of the impression and its respective cast was found for every group (r = 0.40 to 0.80) except group D. Conclusions: The distortions in the horizontal plane of the casts obtained from the impression techniques of groups A to D would probably not affect the clinical fit of implant-retained superstructures. Because of the high variation of deviations (-113 to +124 mu m), the 2-step technique cannot be recommended. The method to measure both impression and cast provided a better understanding of how inaccuracies are caused.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 49 条
  • [1] Accuracy of Definitive Casts Using 4 Implant-Level Impression Techniques in a Scenario of Multi-Implant System With Different Implant Angulations and Subgingival Alignment Levels
    Martinez-Rus, Francisco
    Garcia, Carmen
    Santamaria, Andrea
    Ozcan, Mutlu
    Pradies, Guillermo
    [J]. IMPLANT DENTISTRY, 2013, 22 (03) : 268 - 276
  • [2] Comparison of impression materials for direct multi-implant impressions
    Wee, AG
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (03): : 323 - 331
  • [3] Dimensional accuracy of different techniques used for complete-arch multi-implant impressions
    Ghanem, Rabab A.
    Nassani, Mohammad Z.
    Baroudi, Kusai
    Fattah, Amany Abdel
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2016, 7 (03) : 225 - 231
  • [4] Accuracy of impression scanning compared with stone casts of implant impressions
    Matta, Ragai Edward
    Adler, Werner
    Wichmann, Manfred
    Heckmann, Siegfried Martin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04): : 507 - 512
  • [5] Evaluation of Accuracy of Casts of Multiple Internal Connection Implant Prosthesis Obtained From Different Impression Materials and Techniques: An In Vitro Study
    Pujari, Malesh
    Garg, Pooja
    Prithviraj, D. R.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (02) : 137 - 145
  • [6] Accuracy of Implant Impressions with Different Impression Coping Types and Shapes
    Rashidan, Nayereh
    Alikhasi, Marzieh
    Samadizadeh, Samad
    Beyabanaki, Elahe
    Kharazifard, Mohammad Javad
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (02) : 218 - 225
  • [7] An evaluation of impression techniques for multiple internal connection implant prostheses
    Vigolo, P
    Fonzi, F
    Majzoub, Z
    Cordioli, G
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (05): : 470 - 476
  • [8] Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models
    Choi, Jung-Han
    Lim, Young-Jun
    Yim, Soon-Ho
    Kim, Chang-Whe
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (05) : 761 - 768
  • [9] Accuracy of Three Implant Impression Techniques with Different Impression Materials and Stones
    Chang, Won-Gun
    Vahidi, Farhad
    Bae, Kwang-Hak
    Lim, Bum-Soon
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (01) : 44 - 47
  • [10] A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques
    Patil, Rupali
    Kadam, Pankaj
    Oswal, Chetan
    Patil, Seema
    Jajoo, Shweta
    Gachake, Arati
    [J]. JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (02): : 142 - 148