Comparison of impression materials for direct multi-implant impressions

被引:104
|
作者
Wee, AG [1 ]
机构
[1] Ohio State Univ, Coll Dent, Sect Restorat Dent Prosthondont & Endodont, Columbus, OH 43210 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2000年 / 83卷 / 03期
关键词
D O I
10.1016/S0022-3913(00)70136-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Given that meticulous implant prosthodontic procedures are recommended to obtain the best possible intraoral fit, impression materials that are suitable for use with a direct impression technique warrant further investigation. Purpose. This in vitro study compared the amount of torque required to rotate a square impression coping in an impression and evaluated the accuracy of solid implant casts fabricated from different impression materials. Material and methods. Two direct transfer implant impressions were made using 8 impression materials; the torque required to rotate an impression coping in the impressions was calculated Ten direct transfer implant impressions were made from the master model and poured in a die stone (Resin Rock) for 3 of the 8 initial impression material groups. Linear distances between steel balls placed on each abutment replica were measured with a traveling microscope to determine distortion in the impression procedure for each group. Data were analyzed (P=.05) with ANOVA and Ryan-Einot-Gabriel-Welsch multiple range test for post hoc. Results. With a 1-way ANOVA, average torque values among the material groups differed significantly (P=.001). Polyether (medium consistency) was found to produce the highest overall torque values, followed by addition silicone (high consistency), and then polysulfide (medium consistency). Statistically significant difference was also found among the 3 material groups' mean absolute cast error using a 1-way ANOVA (P=.0086). Implant casts made from polyether (medium) or addition silicone (high) impressions were significantly more accurate than casts made from polysulfide medium impressions. Conclusion. On the basis of the results of this study, the use of either polyether (medium) or addition silicone (high) impression is recommended for direct implant impressions.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [1] Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    Wenz, Hans-Juergen
    Hertrampf, Katrin
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (01) : 39 - 47
  • [2] Multi-Implant Impressions. To Splint or Not to Splint: A Critical Review
    Baig, Mirza Rustum
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) : 66 - 67
  • [3] Dimensional accuracy of different techniques used for complete-arch multi-implant impressions
    Ghanem, Rabab A.
    Nassani, Mohammad Z.
    Baroudi, Kusai
    Fattah, Amany Abdel
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2016, 7 (03) : 225 - 231
  • [4] Accuracy of Definitive Casts Using 4 Implant-Level Impression Techniques in a Scenario of Multi-Implant System With Different Implant Angulations and Subgingival Alignment Levels
    Martinez-Rus, Francisco
    Garcia, Carmen
    Santamaria, Andrea
    Ozcan, Mutlu
    Pradies, Guillermo
    [J]. IMPLANT DENTISTRY, 2013, 22 (03) : 268 - 276
  • [5] Torque resistance of impression copings after direct implant impression: An in vitro evaluation of impression materials with and without adhesive
    Auroy, Pascal
    Nicolas, Emanuel
    Bedouin, Yvan
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (01): : 73 - 80
  • [6] Comparison of Impression Techniques and Materials for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Chagas Amaral, Angela Libia
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 771 - 776
  • [7] Implant overdenture impressions using a dynamic impression concept
    Lee, Byung-Kil
    Park, Sang-Hun
    Lee, Cheong-Hee
    Cho, Jin-Hyun
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (01): : 66 - 70
  • [8] Change of Fluorine Distribution Depending on Multi-Implant Conditions
    Sano, Makoto
    Morita, Takao
    Fuse, Genshu
    [J]. ION IMPLANTATION TECHNOLOGY 2012, 2012, 1496 : 111 - 114
  • [9] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [10] Vinylsiloxanether: A New Impression Material. Clinical Study of Implant Impressions with Vinylsiloxanether versus Polyether Materials
    Enkling, Norbert
    Bayer, Stefan
    Joehren, Peter
    Mericske-Stern, Regina
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (01) : 144 - 151