Accuracy of impression scanning compared with stone casts of implant impressions

被引:31
|
作者
Matta, Ragai Edward [1 ]
Adler, Werner [2 ]
Wichmann, Manfred [1 ]
Heckmann, Siegfried Martin [1 ]
机构
[1] Univ Clin Erlangen, Dept Prosthodont, Dent Clin 2, Glueckstr 11, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, Univ Str, Erlangen, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2017年 / 117卷 / 04期
关键词
SINGLE-UNIT; FIT;
D O I
10.1016/j.prosdent.2016.07.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Accurate virtual implant models are a necessity for the fabrication of precisely fitting superstructures. Purpose. The purpose of this in vitro study was to evaluate different methods with which to build an accurate virtual model of a 3-dimensional implant in the oral cavity; this model would then be used for iterative computer-aided design and computer-aided manufacturing (CAD-CAM) procedures. Material and methods. A titanium master model with 3 rigidly connected implants was manufactured and digitized with a noncontact industrial scanner to obtain a virtual master model. Impressions of the master model with the implant position locators (IPL) were made using vinyl siloxanether material. The impressions were scanned (Impression scanning technique group). For the transfer technique and pick-up technique groups (each group n=20), implant analogs were inserted into the impression copings, impressions were made using polyether, and casts were poured in Type 4 gypsum. The IPLs were screwed into the analogs and scanned. To compare the virtual master model with each virtual test model, a CAD interactive software, ATOS professional, was applied. The Kruskal-Wallis test was subsequently used to determine the overall difference between groups, with the Mann-Whitney U test used for pairwise comparisons. Through Bonferroni correction, the alpha-level was set to.017. Results. The outcome revealed a significant difference among the 3 groups (P<.01) in terms of accuracy. With regard to total deviation, for all axes, the transfer technique generated the greatest divergence, 0.078 mm (+/- 0.022), compared with the master model. Deviation with the pick-up technique was 0.041 mm (0.009), with impression scanning generating the most accurate models with a deviation of 0.022 mm (+/- 0.007). Conclusions. The impression scanning method improved the precision of CAD-CAM-fabricated superstructures.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 50 条
  • [1] THE INFLUENCE OF IMPRESSION TRAYS ON THE ACCURACY OF STONE CASTS POURED FROM IRREVERSIBLE HYDROCOLLOID IMPRESSIONS
    MENDEZ, AJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (03): : 383 - 388
  • [2] Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study
    Alshawaf, Bahaa
    Weber, Hans-Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (08) : 835 - 842
  • [3] Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    Wenz, Hans-Juergen
    Hertrampf, Katrin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (01) : 39 - 47
  • [4] Accuracy of Casts Fabricated by Digital and Conventional Implant Impressions
    Bohner, Lauren
    Hanisch, Marcel
    Canto, Graziela De Luca
    Mukai, Eduardo
    Sesma, Newton
    Tortamano Neto, Pedro
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (02) : 94 - 99
  • [5] ACCURACY OF IMPRESSIONS AND WORKING CASTS USING VINYL SILICONE IMPRESSION MATERIALS
    VANVUUREN, PAJ
    NEL, JC
    BRUNI, NB
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 720 - 720
  • [6] Effects of impression removal methods on accuracy of stone casts.
    Huang, MS
    Chen, CC
    Li, MT
    Li, CH
    Yang, HW
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 547 - 547
  • [7] Accuracy of Implant Impressions with Different Impression Coping Types and Shapes
    Rashidan, Nayereh
    Alikhasi, Marzieh
    Samadizadeh, Samad
    Beyabanaki, Elahe
    Kharazifard, Mohammad Javad
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (02) : 218 - 225
  • [8] Influence of impression technique and material on the accuracy of multiple implant impressions
    Woestmann, Bernd
    Rehmann, Peter
    Balkenhol, Markus
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (04) : 299 - 301
  • [9] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [10] Accuracy of improved stone casts from elastomeric impression materials.
    Kim, KH
    Chang, LT
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1146 - 1146