Accuracy of impression scanning compared with stone casts of implant impressions

被引:31
|
作者
Matta, Ragai Edward [1 ]
Adler, Werner [2 ]
Wichmann, Manfred [1 ]
Heckmann, Siegfried Martin [1 ]
机构
[1] Univ Clin Erlangen, Dept Prosthodont, Dent Clin 2, Glueckstr 11, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Med Informat Biometry & Epidemiol, Univ Str, Erlangen, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2017年 / 117卷 / 04期
关键词
SINGLE-UNIT; FIT;
D O I
10.1016/j.prosdent.2016.07.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Accurate virtual implant models are a necessity for the fabrication of precisely fitting superstructures. Purpose. The purpose of this in vitro study was to evaluate different methods with which to build an accurate virtual model of a 3-dimensional implant in the oral cavity; this model would then be used for iterative computer-aided design and computer-aided manufacturing (CAD-CAM) procedures. Material and methods. A titanium master model with 3 rigidly connected implants was manufactured and digitized with a noncontact industrial scanner to obtain a virtual master model. Impressions of the master model with the implant position locators (IPL) were made using vinyl siloxanether material. The impressions were scanned (Impression scanning technique group). For the transfer technique and pick-up technique groups (each group n=20), implant analogs were inserted into the impression copings, impressions were made using polyether, and casts were poured in Type 4 gypsum. The IPLs were screwed into the analogs and scanned. To compare the virtual master model with each virtual test model, a CAD interactive software, ATOS professional, was applied. The Kruskal-Wallis test was subsequently used to determine the overall difference between groups, with the Mann-Whitney U test used for pairwise comparisons. Through Bonferroni correction, the alpha-level was set to.017. Results. The outcome revealed a significant difference among the 3 groups (P<.01) in terms of accuracy. With regard to total deviation, for all axes, the transfer technique generated the greatest divergence, 0.078 mm (+/- 0.022), compared with the master model. Deviation with the pick-up technique was 0.041 mm (0.009), with impression scanning generating the most accurate models with a deviation of 0.022 mm (+/- 0.007). Conclusions. The impression scanning method improved the precision of CAD-CAM-fabricated superstructures.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 50 条
  • [21] Accuracy of 3D Printed Implant Casts Versus Stone Casts: A Comparative Study in the Anterior Maxilla
    Banjar, Ayman
    Chen, Yo-wei
    Kostagianni, Aikaterini
    Finkelman, Matthew
    Papathanasiou, Aikaterini
    Chochlidakis, Konstantinos
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (09): : 783 - 788
  • [22] ACCURACY OF STONE-CASTS PRODUCED FROM SELECTED ADDITION-TYPE SILICONE IMPRESSIONS
    FINGER, W
    OHSAWA, M
    SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1983, 91 (01): : 61 - 65
  • [23] ACCURACY OF STONE-CASTS PRODUCED FROM SELECTED ADDITION-TYPE SILICONE IMPRESSIONS
    OHSAWA, M
    FINGER, W
    JOURNAL OF DENTAL RESEARCH, 1983, 62 (04) : 471 - 471
  • [24] Effect of Implant Angulation and Depth on the Accuracy of Casts Using the Open Tray Splinted Impression Technique
    Taduri, Thanmai
    Mathur, Somil
    Upadhyay, Snehal
    Patel, Khushali
    Shah, Meena
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (06) : 447 - 454
  • [25] Displacement of implant components from impressions to definitive casts
    Kim, Sunjai
    Nicholls, Jack I.
    Han, Chong-Hyun
    Lee, Keun-Woo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (05) : 747 - 755
  • [26] EFFECT OF IMPRESSION TRAY DESIGN AND IMPRESSION TECHNIQUE UPON THE ACCURACY OF STONE CASTS PRODUCED FROM A PUTTY-WASH POLYVINYL SILOXANE IMPRESSION MATERIAL
    SAUNDERS, WP
    SHARKEY, SW
    SMITH, GM
    TAYLOR, WG
    JOURNAL OF DENTISTRY, 1991, 19 (05) : 283 - 289
  • [27] Influence of intraoral scanning coverage on the accuracy of digital implant impressions - An in vitro study
    Wang, Zhen-yu
    Gong, Yu
    Liu, Fei
    Chen, Du
    Shen, Jie-fei
    JOURNAL OF DENTISTRY, 2024, 143
  • [28] BACTERICIDAL EFFECT OF A DISINFECTANT DENTAL STONE ON IRREVERSIBLE HYDROCOLLOID IMPRESSIONS AND STONE CASTS
    SCHUTT, RW
    JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (05): : 605 - 607
  • [29] A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques
    Patil, Rupali
    Kadam, Pankaj
    Oswal, Chetan
    Patil, Seema
    Jajoo, Shweta
    Gachake, Arati
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2016, 6 (02): : 142 - 148
  • [30] DISTORTION ANALYSIS OF STONE CASTS MADE FROM IMPRESSION MATERIALS
    LINKE, BA
    NICHOLLS, JI
    FAUCHER, RR
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (06): : 794 - 802