EFFECT OF IMPRESSION TRAY DESIGN AND IMPRESSION TECHNIQUE UPON THE ACCURACY OF STONE CASTS PRODUCED FROM A PUTTY-WASH POLYVINYL SILOXANE IMPRESSION MATERIAL

被引:28
|
作者
SAUNDERS, WP
SHARKEY, SW
SMITH, GM
TAYLOR, WG
机构
[1] Department of Conservative Dentistry, Glasgow Dental Hospital and School, Glasgow, Scotland
关键词
IMPRESSIONS; A-SILICONES; IMPRESSION TRAYS; TECHNIQUE;
D O I
10.1016/0300-5712(91)90072-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined the accuracy of stone casts produced from impressions taken in stock polycarbonate trays, some of which had been strengthened with autopolymerizing polymethyl methacrylate resin. Three techniques were used to make the impression of an acrylic master model of the mandibular arch on which two extracoronal preparations for bridgework and one intracoronal inlay preparation had been carried out. Each preparation had been indented with a reference point for later measurement. The impression material was a putty-wash polyvinyl siloxane material. Five impressions were taken for each type of tray for each impression technique and these were cast in die-stone after 24 h. The distances between the points were measured with a reflex microscope and the means determined for each design of tray. The mean difference between casts produced from the various tray designs and the acrylic master model were determined for each of the distances between the three measuring points for the various impression techniques. Statistical analysis showed that, with the polycarbonate stock trays, there were significant differences between some of the modifications and between them and the acrylic model. for the three distances (P < 0.05). These differences were limited to one measurement for one design of tray for each of the two-stage impression methods. With the one-stage technique the unreinforced tray and those reinforced with acrylic, over the heels and anteriorly, and the barred design were statistically significantly different from the acrylic model for measurement A-B. It would appear from this study that the design of tray, or the impression technique employed, has little effect on the accuracy of impressions made with the polyvinyl siloxane material tested when used as a putty-wash and a two-stage technique. but that the accuracy of the impression material within the bulk of the material (A-B) was affected adversely using a one-stage technique.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 45 条
  • [1] Accuracy of three polyvinyl siloxane putty-wash impression techniques
    Nissan, J
    Laufer, BZ
    Brosh, T
    Assif, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (02): : 161 - 165
  • [2] EFFECT OF IMPRESSION TRAY DESIGN UPON THE ACCURACY OF STONE CASTS PRODUCED FROM A SINGLE-PHASE MEDIUM-BODIED POLYVINYL SILOXANE IMPRESSION MATERIAL
    SAUNDERS, WP
    SHARKEY, SW
    SMITH, GM
    TAYLOR, WG
    [J]. JOURNAL OF DENTISTRY, 1992, 20 (03) : 189 - 192
  • [3] A CONTROLLED PUTTY-WASH IMPRESSION TECHNIQUE
    MARSHAK, B
    ASSIF, D
    PILO, R
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1990, 64 (06): : 635 - 636
  • [4] A modified one-step putty-wash impression technique
    Wu, Aaron Yu-Jen
    Donovan, Terry E.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (03): : 245 - 246
  • [5] Influence of Tray Rigidity and Impression Technique on Accuracy of Polyvinyl Siloxane Impressions
    Hoyos, Alex
    Soederholm, Karl-Johan
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (01) : 49 - 54
  • [6] A modified putty-wash vinyl polysiloxane impression technique for fixed prosthodontics
    Chaimattayompol, Nopsaran
    Park, Dongwoo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (06): : 483 - 485
  • [7] EFFECT OF CONTAMINANTS ON THE ADHESION OF LIGHT-BODIED SILICONES TO PUTTY SILICONES IN PUTTY-WASH IMPRESSION TECHNIQUE
    TJAN, AHL
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (05): : 562 - 567
  • [8] Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions
    Nissan, J
    Gross, M
    Shifman, A
    Assif, D
    [J]. JOURNAL OF ORAL REHABILITATION, 2002, 29 (04) : 357 - 361
  • [9] CLINICALLY ORIENTED ASSESSMENT OF THE ACCURACY OF 3 PUTTY-WASH SILICONE IMPRESSION TECHNIQUES
    TJAN, AHL
    WHANG, SB
    TJAN, AH
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1984, 108 (06): : 973 - 975
  • [10] USE OF POLYVINYL SILOXANE MATERIAL FOR AN ALTERED CAST IMPRESSION TRAY
    Hsu, Yung-tsung
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03): : 695 - 696