10 Volt Automated Direct Comparison of Two Cryocooled Programmable Josephson Voltage Standards

被引:0
|
作者
Rufenacht, Alain [1 ]
Tang, Yi-hua [2 ]
Fox, Anna E. [1 ]
Dresselhaus, Paul D. [1 ]
Burroughs, Charles J. [1 ]
Schwall, Robert E. [1 ]
Benz, Samuel P. [1 ]
机构
[1] NIST, Boulder, CO 80305 USA
[2] NIST, Gaithersburg, MD 20899 USA
关键词
Josephson arrays; Precision measurements; Uncertainty; Voltage measurement;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have performed direct dc comparisons between two cryocooled 10 V programmable Josephson voltage standards utilizing an automated synchronization scheme for the voltage reversals, which enables the use of a high sensitivity null detector on its 3 mu V range by preventing any overload condition. No switches or manual operations are necessary to protect the null detector. Comparing the two systems under various test conditions provides robust verification of ideal system performance, and enables verification of the key components of the uncertainty budget for both the measurement methods and system operations.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Automated 10 Volt Josephson voltage standard system operating with liquid helium and with a cryocooler
    Schubert, M.
    Starkloff, M.
    Meyer, M.
    Wende, G.
    Anders, S.
    Steinbach, B.
    May, T.
    Meyer, H. -G.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 370 - +
  • [32] Operation of compact cryocooled 2V programmable josephson voltage standard at NIM
    Wang Zengmin
    Li Honghui
    He Qing
    Qu Jifeng
    Gao Yuan
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 361 - 368
  • [33] Calibration System for Zener Voltage Standards Using a 10 V Programmable Josephson Voltage Standard at NMIJ
    Maruyama, Michitaka
    Iwasa, Akio
    Yamamori, Hirotake
    Chen, Shih-Fang
    Urano, Chiharu
    Kaneko, Nobu-hisa
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (06) : 1606 - 1612
  • [34] INTERNATIONAL DIRECT COMPARISON OF 2 JOSEPHSON-EFFECT VOLTAGE STANDARDS
    HARTLAND, A
    WITT, TJ
    REYMANN, D
    FINNEGAN, TF
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1978, 27 (04) : 470 - 474
  • [35] Direct 10 V Josephson Voltage Standard comparison between a programmable SINIS array and a conventional SIS array
    Djordjevic, S.
    Seron, O.
    Solve, S.
    Chayramy, R.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 582 - +
  • [36] North American interlaboratory comparison of 10 V Josephson voltage standards
    Deaver, D
    Miller, WB
    Pardo, L
    Jaeger, K
    Plowman, D
    Hamilton, CA
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 249 - 250
  • [37] Interlaboratory comparison of Josephson voltage standards
    Deaver, D
    Miller, WB
    Pardo, L
    Jaeger, K
    Plowman, D
    Hamilton, CA
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 199 - 202
  • [38] A COMPARISON OF ONE VOLT JOSEPHSON-JUNCTION ARRAY VOLTAGE STANDARDS DRIVEN BY A COMMON MICROWAVE SOURCE
    REYMANN, D
    LOHIVE, JP
    GENEVES, G
    METROLOGIA, 1994, 31 (01) : 35 - 37
  • [39] Metallic-barrier junctions for programmable Josephson voltage standards
    Kautz, RL
    Benz, SP
    APPLIED SUPERCONDUCTIVITY 1995, VOLS. 1 AND 2: VOL 1: PLENARY TALKS AND HIGH CURRENT APPLICATIONS; VOL 2: SMALL SCALE APPLICATIONS, 1995, 148 : 1407 - 1410
  • [40] Programmable voltage standards based on HTS Josephson junction arrays
    Klushin, AM
    Borovitskii, SI
    Weber, C
    Sodtke, E
    Semerad, R
    Prusseit, W
    Gelikonova, VD
    Kohlstedt, H
    APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2, 1997, (158): : 587 - 590