Direct 10 V Josephson Voltage Standard comparison between a programmable SINIS array and a conventional SIS array

被引:0
|
作者
Djordjevic, S. [1 ]
Seron, O. [1 ]
Solve, S. [2 ]
Chayramy, R. [2 ]
机构
[1] Lab Natl Metrol & Essais, 29 Ave Hennequin, Trappes, France
[2] Pavillon Breteuil, Bur Int Poids & Mesures, Sevres, France
关键词
D O I
10.1109/CPEM.2008.4574913
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In December 2007, a comparison of the 10 V Josephson Array Voltage Standard (JAVS) of the LNE was performed with that of the BIPM in the framework of BIPM.EM-K10.b comparison. During the week allotted to the exercise, the measurement setup was optimized to achieve a relative voltage difference of 7x10(-12) within a relative Type A uncertainty of 8x10(-12). We then took the opportunity to carry out a direct comparison of a 10 V PTB programmable array against the LNE JAVS. We report on the experiments performed to establish the uncertainty budget. We present the characterization of a 10 V SINIS array. We conclude with the results of a direct comparison against the LNE JAVS.
引用
收藏
页码:582 / +
页数:2
相关论文
共 50 条
  • [1] Direct Comparison between the NIST 10 V Conventional Josephson Voltage Standard and 2.5 V Programmable Josephson Voltage Standard
    Jaiswal, Shiv Kumar
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2011, 26 (04): : 339 - 348
  • [2] Direct comparison between the NIST 10 V Conventional Josephson Voltage Standard and 2.5 V Programmable Josephson Voltage Standard
    Shiv Kumar Jaiswal
    [J]. MAPAN, 2011, 26 : 339 - 348
  • [3] Direct comparison between a programmable and a conventional Josephson voltage standard at the level of 10V
    Djordjevic, S.
    Seron, O.
    Solve, S.
    Chayramy, R.
    [J]. METROLOGIA, 2008, 45 (04) : 429 - 435
  • [4] Application of a 10 V Programmable Josephson Voltage Standard in Direct Comparison With Conventional Josephson Voltage Standards
    Tang, Yi-Hua
    Wachter, James
    Ruefenacht, Alain
    FitzPatrick, Gerald J.
    Benz, Samuel P.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (12) : 3458 - 3466
  • [5] Dry cooling of a 10 V programmable Josephson voltage standard array
    Starkloff, M.
    Schubert, M.
    Lee, J.
    Behr, R.
    Palafox, L.
    Boeck, A. C.
    Fleischmann, P. M.
    Peiselt, K.
    [J]. 2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [6] Direct comparison between the NIST 10 V Compact Josephson Voltage Standard and the 2.5 V Programmable Josephson Voltage Standard
    Jaiswal, Shiv Kumar
    Tang, Y.
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2009, 24 (04): : 207 - 214
  • [7] Direct comparison between the NIST 10 V Compact Josephson Voltage Standard and the 2.5 V Programmable Josephson Voltage Standard
    Shiv Kumar Jaiswal
    Y. Tang
    [J]. MAPAN, 2009, 24 : 207 - 214
  • [8] Measurement of a SINIS-Type Josephson Junction Array Voltage with Respect to the Voltage Standard Based on a SIS-Type Josephson Junction Array
    O. V. Karpov
    V. D. Kutovoi
    S. V. Sherstobitov
    J. Niemeyer
    [J]. Instruments and Experimental Techniques, 2001, 44 : 655 - 661
  • [9] Measurement of a SINIS-type Josephson junction array voltage with respect to the voltage standard based on a SIS-type Josephson junction array
    Karpov, OV
    Kutovoi, VD
    Sherstobitov, SV
    Niemeyer, J
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2001, 44 (05) : 655 - 661
  • [10] Measurement of a SINIS-type Josephson junction array voltage with respect to the voltage standard based on a SIS-type Josephson junction array
    Karpov, O.V.
    Kutovoj, V.D.
    Sherstobitov, S.V.
    Niemeyer, J.
    [J]. Pribory i Tekhnika Eksperimenta, 2001, 44 (05): : 91 - 97