10 Volt Automated Direct Comparison of Two Cryocooled Programmable Josephson Voltage Standards

被引:0
|
作者
Rufenacht, Alain [1 ]
Tang, Yi-hua [2 ]
Fox, Anna E. [1 ]
Dresselhaus, Paul D. [1 ]
Burroughs, Charles J. [1 ]
Schwall, Robert E. [1 ]
Benz, Samuel P. [1 ]
机构
[1] NIST, Boulder, CO 80305 USA
[2] NIST, Gaithersburg, MD 20899 USA
关键词
Josephson arrays; Precision measurements; Uncertainty; Voltage measurement;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have performed direct dc comparisons between two cryocooled 10 V programmable Josephson voltage standards utilizing an automated synchronization scheme for the voltage reversals, which enables the use of a high sensitivity null detector on its 3 mu V range by preventing any overload condition. No switches or manual operations are necessary to protect the null detector. Comparing the two systems under various test conditions provides robust verification of ideal system performance, and enables verification of the key components of the uncertainty budget for both the measurement methods and system operations.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Automated direct comparison of two cryocooled 10 volt programmable Josephson voltage standards
    Rufenacht, Alain
    Tang, Yi-hua
    Solve, Stephane
    Fox, Anna E.
    Dresselhaus, Paul D.
    Burroughs, Charles J.
    Schwall, Robert E.
    Chayramy, Regis
    Benz, Samuel P.
    METROLOGIA, 2018, 55 (04) : 585 - 596
  • [2] Cryocooled 10 V Programmable Josephson Voltage Standard
    Ruefenacht, Alain
    Howe, Logan A.
    Fox, Anna E.
    Schwall, Robert E.
    Dresselhaus, Paul D.
    Burroughs, Charles J., Jr.
    Benz, Samuel P.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (06) : 1477 - 1482
  • [3] Application of a 10 V Programmable Josephson Voltage Standard in Direct Comparison With Conventional Josephson Voltage Standards
    Tang, Yi-Hua
    Wachter, James
    Ruefenacht, Alain
    FitzPatrick, Gerald J.
    Benz, Samuel P.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (12) : 3458 - 3466
  • [4] Cryocooled Programmable and Pulse-driven Josephson Voltage Standards at INRiM
    Durandetto, Paolo
    Monticone, Eugenio
    Trinchera, Bruno
    Serazio, Danilo
    Sosso, Andrea
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 791 - 795
  • [5] Cryocooled 10 V Programmable Josephson Voltage Standard at CMS
    Chen, Shih-Fang
    Han, Chou-Hsun
    Cular, Stefan
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [6] Direct DC Voltages Comparison between two Programmable Josephson Voltage Standards at SCL
    Yang, S.
    Cular, S.
    Rufenacht, A.
    Burroughs, C. J.
    Dresselhaus, P. D.
    Benz, S. P.
    Ng, M. N.
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [7] A direct DC 10 V comparison between the NIMJ and the BIPM Programmable Josephson Voltage Standards
    Solve, Stephane
    Chayramy, Regis
    Maruyama, Michitaka
    Urano, Chiharu
    Kaneko, Nobu-hisa
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [8] Comparison of the 10 V josephson voltage standards of the conventional and the programmable at NIM
    Li Honghui
    Gao Yuan
    Wang Zengmin
    PROCEEDINGS OF 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL. 2, 2015, : 713 - 717
  • [9] Research Progress on the Cryocooled 10 V Programmable Josephson Voltage Standard at NIM
    Wang, Zengmin
    Li, Honghui
    Chen, Yan
    Liao, Fujian
    Wang, Lei
    Zhang, Jiangtao
    Jia, Zhengsen
    2024 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CPEM 2024, 2024,
  • [10] Cryocooled Josephson standards for AC voltage metrology
    Durandetto, P.
    Sosso, A.
    Monticone, E.
    Trinchera, B.
    Fretto, M.
    Lacquaniti, V.
    7TH YOUNG RESEARCHER MEETING, 2017, 841