Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography

被引:13
|
作者
Zhao, W [1 ]
Ji, WG [1 ]
Rowlands, JA [1 ]
Debrie, A [1 ]
机构
[1] SUNY Stony Brook, Hlth Sci Ctr L 4, Dept Radiol, Stony Brook, NY 11794 USA
关键词
flat-panel detectors; digital mammography; MTF; NPS; DQE; selenium;
D O I
10.1117/12.430876
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our work is to investigate and understand the factors affecting the imaging performance of amorphous selenium (a-Se) flat-panel detectors for digital mammography. Both theoretical and experimental methods were developed to investigate the spatial frequency dependent detective quantum efficiency [DQE(f)] of a-Se flat-panel detectors for digital mammography. Since the k-edge of a-Se is 12.66 keV and within the energy range of a mammographic spectrum, a cascaded linear system model was developed which takes into account the effect of k-fluorescence on the modulation transfer function (MTF), noise power spectrum (NPS) and DQE(f) of the detector. This model was used to understand the performance of a prototype detector with 85 mum. pixel size. The presampling MTF, NPS and DQE(f) of the prototype were measured, and compared to the theoretical calculation by the model. The calculation showed that k-fluorescence reduces the MTF by 15% at the Nyquist frequency (f(NY)) of the prototype detector, and the NPS at f(NY) was reduced to 82% of that at zero spatial frequency. The measurement of presampling MTF of the prototype detector revealed an additional source of blurring, which was attributed to the blocking layer at the interface between a-Se and the active matrix. This introduced high frequency drop in both presampling MTF and NPS, and reduced aliasing in the NPS. As a result, the DQE(f) of the prototype detector at f(NY) approaches 50% of that at zero spatial frequency.
引用
下载
收藏
页码:536 / 546
页数:11
相关论文
共 50 条
  • [31] A comparison of lesion detection accuracy using digital mammography and flat-panel CT breast imaging
    Gong, X
    Vedula, AA
    Thacker, S
    Glick, SJ
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 860 - 869
  • [32] New Development of Blocking Layer and Doping of Amorphous Selenium to Improve the Imaging Performance of Flat-Panel Imager with Avalanche Gain
    Orlik, C.
    Howansky, A.
    Leveille, S.
    Mishchenko, A.
    Stavro, J.
    Goldan, A.
    Scheuermann, J.
    Zhao, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E321 - E321
  • [33] X-RAY-IMAGING USING AMORPHOUS SELENIUM - FEASIBILITY OF A FLAT-PANEL SELF-SCANNED DETECTOR FOR DIGITAL RADIOLOGY
    ZHAO, W
    ROWLANDS, JA
    MEDICAL PHYSICS, 1995, 22 (10) : 1595 - 1604
  • [34] Parametric Modeling for Indirect Flat-Panel Detectors in Radiography Imaging
    Kim, Dong Sik
    2022 37TH INTERNATIONAL TECHNICAL CONFERENCE ON CIRCUITS/SYSTEMS, COMPUTERS AND COMMUNICATIONS (ITC-CSCC 2022), 2022, : 202 - 204
  • [35] The amorphous selenium based flat-panel detector. Clinical experiences
    Schmidt, EL
    Herbig, W
    RADIOLOGE, 2003, 43 (05): : 374 - 378
  • [36] Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience
    Liu, Xinming
    Lai, Chao-Jen
    Chen, Lingyun
    Han, Tao
    Zhong, Yuncheng
    Shen, Youtao
    Wang, Tianpeng
    Shaw, Chris C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22): : 6959 - 6978
  • [37] Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system
    Zhao, Bo
    Zhao, Wei
    MEDICAL PHYSICS, 2008, 35 (05) : 1978 - 1987
  • [38] Dual-energy digital mammography: Implementation on a flat-panel digital mammography system - A work-in-progress
    Kappadath, SC
    Shaw, CC
    Lai, C
    Liu, X
    Whitman, GJ
    RADIOLOGY, 2002, 225 : 118 - 118
  • [39] Improved thermal stability of antimony-doped amorphous selenium film for X-ray flat-panel detectors
    Chen, Zexiang
    Dong, Miao
    Li, Chun
    Shao, Shengzi
    Hu, Tianyong
    Kang, Dequn
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2013, 210 (03): : 580 - 584
  • [40] Characterization of a direct, full-field flat-panel digital mammography detector
    Zhao, B
    Zhao, W
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 157 - 167