Improved thermal stability of antimony-doped amorphous selenium film for X-ray flat-panel detectors

被引:6
|
作者
Chen, Zexiang [1 ]
Dong, Miao [1 ]
Li, Chun [1 ]
Shao, Shengzi [1 ]
Hu, Tianyong [1 ]
Kang, Dequn [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Optoelect Informat, Chengdu 610054, Peoples R China
基金
美国国家科学基金会;
关键词
amorphous selenium; doping; X-ray detectors; CHEST RADIOGRAPHY; IMAGE SENSORS; A-SE; ALLOYS; PHOTOCONDUCTORS; MAMMOGRAPHY; PERFORMANCE; SYSTEM;
D O I
10.1002/pssa.201228432
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Amorphous selenium (a-Se) film is a promising photoconductive material for X-ray flat-panel detectors (FPD) application. However, a-Se tends to be crystalline Se at near room temperature. This remarkable temperature sensitivity limits its practical application. To prevent the near-room-temperature crystallization of a-Se film, we fabricate antimony (Sb)-doped a-Se films using a vacuum evaporation technique equipped with an in situ cooling trap. We experimentally demonstrate that the Sb doping improves the thermal stability of a-Se film while possessing a similar X-ray photoelectric conversion efficiency as the pure a-Se film. After air annealing at 50 degrees C for 90min, the X-ray diffraction (XRD) results of the 4.1at.% Sb-doped a-Se film shows no detectable crystallization diffraction peak. Upon applying an electric field of 10V mu m1, such Sb-doped a-Se film exhibits dark current density below 1nAcm2, while under an X-ray dosage of about 4mGy, the annealed Sb-doped a-Se film shows a photocurrent density of more than 100nAcm2.
引用
下载
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [1] Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors
    Zhao, W
    DeCrescenzo, G
    Rowlands, JA
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 9 - 20
  • [2] Flat-panel detectors in X-ray systems
    Spahn, M
    Heer, V
    Freytag, R
    RADIOLOGE, 2003, 43 (05): : 340 - +
  • [3] Direct-conversion flat-panel X-ray image detectors
    Kasap, SO
    Rowlands, JA
    IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 2002, 149 (02): : 85 - 96
  • [4] Scintillator-based flat-panel x-ray imaging detectors
    Granfors, Paul R.
    Albagli, Douglas
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2009, 17 (06) : 535 - 542
  • [5] A semiempirical linear model of indirect, flat-panel x-ray detectors
    Huang, Shih-Ying
    Yang, Kai
    Abbey, Craig K.
    Boone, John M.
    MEDICAL PHYSICS, 2012, 39 (04) : 2108 - 2118
  • [6] Selenium-based amorphous silicon flat-panel digital X-ray imager for protein crystallography
    Sultana, Afrin
    Karim, K. S.
    Rowlands, J. A.
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2008, 33 (3-4): : 139 - 143
  • [7] Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography
    Zhao, W
    Ji, WG
    Rowlands, JA
    Debrie, A
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 536 - 546
  • [8] Characterization of a flat-panel amorphous silicon detector for X-ray computed tomography
    Lee, H.-R.
    Ellingson, W.
    Journal of X-Ray Science and Technology, 2001, 9 (01) : 43 - 53
  • [9] A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors
    Starman, Jared
    Star-Lack, Josh
    Virshup, Gary
    Shapiro, Edward
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2012, 39 (10) : 6035 - 6047
  • [10] Finding an improved amorphous-silicon x-ray flat-panel detector configuration for the in-line geometry
    Fast, M. F.
    Teymurazyan, A.
    Pang, G.
    Oelfke, U.
    Rowlands, J. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2305 - 2324