Reducing and correcting for contamination of ecosystem water stable isotopes measured by isotope ratio infrared spectroscopy

被引:25
|
作者
Schmidt, Markus [1 ]
Maseyk, Kadmiel [1 ]
Lett, Celine [1 ]
Biron, Philippe [1 ]
Richard, Patricia [1 ]
Bariac, Thierry [1 ]
Seibt, Ulli [1 ,2 ]
机构
[1] Univ Paris 06, BIOEMCO, INRA, ENS,IRD,CNRS,UMR 7618, F-78850 Thiverval Grignon, France
[2] Univ Calif Los Angeles, Dept Atmospher & Ocean Sci, Los Angeles, CA 90095 USA
基金
欧洲研究理事会;
关键词
RING-DOWN SPECTROSCOPY; MASS-SPECTROMETRY; SPATIAL VARIATION; LEAF WATER; SOIL-WATER; PLANT; EXTRACTION; O-18; DISCREPANCIES; DELTA-O-18;
D O I
10.1002/rcm.5317
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Concern exists about the suitability of laser spectroscopic instruments for the measurement of the O-18/O-16 and H-2/H-1 values of liquid samples other than pure water. It is possible to derive erroneous isotope values due to optical interference by certain organic compounds, including some commonly present in ecosystem-derived samples such as leaf or soil waters. Here we investigated the reliability of wavelength-scanned cavity ring-down spectroscopy (CRDS) O-18/O-16 and H-2/H-1 measurements from a range of ecosystem-derived waters, through comparison with isotope ratio mass spectrometry (IRMS). We tested the residual of the spectral fit S-r calculated by the CRDS instrument as a means to quantify the difference between the CRDS and IRMS delta-values. There was very good overall agreement between the CRDS and IRMS values for both isotopes, but differences of up to 2.3 parts per thousand (delta O-18 values) and 23 parts per thousand (delta H-2 values) were observed in leaf water extracts from Citrus limon and Alnus cordata. The S-r statistic successfully detected contaminated samples. Treatment of Citrus leaf water with activated charcoal reduced, but did not eliminate, delta H-2(CRDS)-delta H-2(IRMS) linearly for the tested range of 0-20 % charcoal. The effect of distillation temperature on the degree of contamination was large, particularly for delta H-2 values but variable, resulting in positive, negative or no correlation with distillation temperature. S-r and delta(CRDS) - delta(IRMS) were highly correlated, in particular for delta H-2 values, across the range of samples that we tested, indicating the potential to use this relationship to correct the delta-values of contaminated plant water extracts. We also examined the sensitivity of the CRDS system to changes in the temperature of its operating environment. We found that temperature changes >= 4 degrees C for delta O-18 values and >= 10 degrees C for delta H-2 values resulted in errors larger than the CRDS precision for the respective isotopes and advise the use of such instruments only in sufficiently temperature-stabilised environments. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:141 / 153
页数:13
相关论文
共 50 条
  • [1] Applications of Isotope Ratio Infrared Spectroscopy (IRIS) to Analysis of Stable Isotopic Compositions of Liquid Water
    Jung, Youn-Young
    Koh, Dong-Chan
    Lee, Jeonghoon
    Ko, Kyung-Seok
    ECONOMIC AND ENVIRONMENTAL GEOLOGY, 2013, 46 (06): : 495 - 508
  • [2] Detailed assessment of isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters
    Zhao, Liangju
    Xiao, Honglang
    Zhou, Jian
    Wang, Lixin
    Cheng, Guodong
    Zhou, Maoxian
    Yin, Li
    McCabe, Matthew F.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 3071 - 3082
  • [3] Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters
    West, Adam G.
    Goldsmith, Gregory R.
    Brooks, Paul D.
    Dawson, Todd E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (14) : 1948 - 1954
  • [4] Comments on "Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters"
    Brand, Willi A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (17) : 2687 - 2688
  • [5] Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS)
    West, A. G.
    Goldsmith, G. R.
    Matimati, I.
    Dawson, T. E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (16) : 2268 - 2274
  • [6] Analysis of the hydrogen and oxygen stable isotope ratios of beverage waters without prior water extraction using isotope ratio infrared spectroscopy
    Chesson, Lesley A.
    Bowen, Gabriel J.
    Ehleringer, James R.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (21) : 3205 - 3213
  • [7] Optimization of instrument setup and post-run corrections for oxygen and hydrogen stable isotope measurements of water by isotope ratio infrared spectroscopy (IRIS)
    van Geldern, Robert
    Barth, Johannes A. C.
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2012, 10 : 1024 - 1036
  • [8] Isotope ratio infrared spectroscopy analysis of water samples without memory effects
    de Graaf, Stefan
    Vonhof, Hubert B.
    Levy, Elan J.
    Markowska, Monika
    Haug, Gerald H.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (08)
  • [9] A new concept for sensitive in situ stable isotope ratio infrared spectroscopy based on sample modulation
    Werle, P
    Dyroff, C
    Zahn, A
    Mazzinghi, P
    D'Amato, F
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2005, 41 (04) : 323 - 333
  • [10] Optical Spectroscopy for Analysis of the Ratio of Stable Isotopes. Competition or Alternative for Conventional Mass Spectroscopy of Stable Isotopes (IRMS)?
    Kubasek, Jiri
    CHEMICKE LISTY, 2016, 110 (03): : 166 - 173