Optimization of instrument setup and post-run corrections for oxygen and hydrogen stable isotope measurements of water by isotope ratio infrared spectroscopy (IRIS)

被引:186
|
作者
van Geldern, Robert [1 ]
Barth, Johannes A. C. [1 ]
机构
[1] Univ Erlangen Nurnberg, GeoZentrum Nordbayern, D-91054 Erlangen, Germany
来源
关键词
RING-DOWN SPECTROSCOPY; CHROMIUM REDUCTION; SAMPLES; DELTA-O-18; PRECISION; DELTA-H-2; NORMALIZATION; SPECTROMETRY; CALIBRATION; EXTRACTION;
D O I
10.4319/lom.2012.10.1024
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Light stable isotope analyses of hydrogen (H-2/H-1) and oxygen (O-18/O-16) of water are used in many terrestrial and marine aquatic studies. The advantage of using stable isotope ratios is that water molecules serve as ubiquitous and already present natural tracers. Within recent years, these analyses have been revolutionized by the development of new isotope ratio laser spectroscopy (IRIS) systems that are cheaper, more robust, and mobile compared with traditional isotope ratio mass spectrometry (IRMS). Although easier to operate, laser systems also need thorough calibration with international reference materials, and raw data need correction for analytical effects (i.e., memory and drift). This study presents modifications to the hardware for liquid water injection, an optimized sequence layout and a simple post-run correction procedure. These protocols will maximize precision, accuracy, and sample throughput via an efficient memory correction. The number of injections per unknown sample can be reduced to 4 or less. This procedure meets the demands of faster throughput with reduced costs per analysis. Procedures presented here are based on real analyses. They were also verified by an international proficiency test and traditional IRMS techniques.
引用
收藏
页码:1024 / 1036
页数:13
相关论文
共 15 条
  • [1] Analysis of the hydrogen and oxygen stable isotope ratios of beverage waters without prior water extraction using isotope ratio infrared spectroscopy
    Chesson, Lesley A.
    Bowen, Gabriel J.
    Ehleringer, James R.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (21) : 3205 - 3213
  • [2] Applications of Isotope Ratio Infrared Spectroscopy (IRIS) to Analysis of Stable Isotopic Compositions of Liquid Water
    Jung, Youn-Young
    Koh, Dong-Chan
    Lee, Jeonghoon
    Ko, Kyung-Seok
    ECONOMIC AND ENVIRONMENTAL GEOLOGY, 2013, 46 (06): : 495 - 508
  • [3] Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS)
    West, A. G.
    Goldsmith, G. R.
    Matimati, I.
    Dawson, T. E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (16) : 2268 - 2274
  • [4] Analysis of hydrogen and oxygen isotope in water sample using isotope ratio mass spectrometry and laser spectroscopy
    Zhang, Lin
    Han, Mei
    Jia, Yan-Kun
    Liu, Jun
    Journal of Chinese Mass Spectrometry Society, 2015, 36 (06) : 559 - 564
  • [5] STABLE ISOTOPE RATIO MEASUREMENTS IN HYDROGEN, NITROGEN, AND OXYGEN USING RAMAN-SCATTERING
    HARNEY, RC
    BLOOM, SD
    MILANOVICH, FP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1975, 170 (AUG24): : 96 - 96
  • [6] Reducing and correcting for contamination of ecosystem water stable isotopes measured by isotope ratio infrared spectroscopy
    Schmidt, Markus
    Maseyk, Kadmiel
    Lett, Celine
    Biron, Philippe
    Richard, Patricia
    Bariac, Thierry
    Seibt, Ulli
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (02) : 141 - 153
  • [7] A new isotopic reference material for stable hydrogen and oxygen isotope-ratio measurements of water-USGS50 Lake Kyoga Water
    Coplen, Tyler B.
    Wassenaar, Leonard I.
    Mukwaya, Christine
    Qi, Haiping
    Lorenz, Jennifer M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (21) : 2078 - 2082
  • [8] Lake Louise Water (USGS47): A new isotopic reference water for stable hydrogen and oxygen isotope measurements
    Qi, Haiping
    Lorenz, Jennifer M.
    Coplen, Tyler B.
    Tarbox, Lauren
    Mayer, Bernhard
    Taylor, Steve
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (04) : 351 - 354
  • [9] A Hydrogen Gas-Water Equilibration Method Produces Accurate and Precise Stable Hydrogen Isotope Ratio Measurements in Nutrition Studies
    Wong, William W.
    Clarke, Lucinda L.
    JOURNAL OF NUTRITION, 2012, 142 (11): : 2057 - 2062
  • [10] Optimization of oxygen-18 ratio measurements by equilibration Isotope ratio mass spectrometry using various water content matrices
    Guyon, Francois
    Gaillard, Laetitia
    Magdas, Dana Alina
    TALANTA, 2018, 189 : 653 - 656