Detailed assessment of isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters

被引:43
|
作者
Zhao, Liangju [2 ,3 ,4 ]
Xiao, Honglang [2 ,4 ]
Zhou, Jian [3 ]
Wang, Lixin [1 ,5 ]
Cheng, Guodong [3 ]
Zhou, Maoxian [2 ,4 ]
Yin, Li [2 ,4 ]
McCabe, Matthew F. [1 ]
机构
[1] Univ New S Wales, Sch Civil & Environm Engn, Sydney, NSW, Australia
[2] Chinese Acad Sci, Cold & Arid Reg Environm & Engn Res Inst, Key Lab Ecohydrol & Integrated River Basin Sci, Lanzhou 730000, Peoples R China
[3] Chinese Acad Sci, State Key Lab Frozen Soil Engn, Cold & Arid Reg Environm & Engn Res Inst, Lanzhou 730000, Peoples R China
[4] Key Lab Heihe Ecohydrol & Basin Sci Gansu Prov, Lanzhou 730000, Peoples R China
[5] Chinese Acad Sci, Inst Appl Ecol, State Key Lab Forest & Soil Ecol, Shenyang 110164, Peoples R China
基金
中国国家自然科学基金;
关键词
VOLATILE ORGANIC-COMPOUNDS; RING-DOWN SPECTROSCOPY; DELTA-O-18; DELTA-H-2; OXYGEN; FIELD; LEAF;
D O I
10.1002/rcm.5204
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As an alternative to isotope ratio mass spectrometry (IRMS), the isotope ratio infrared spectroscopy (IRIS) approach has the advantage of low cost, continuous measurement and the capacity for field-based application for the analysis of the stable isotopes of water. Recent studies have indicated that there are potential issues of organic contamination of the spectral signal in the IRIS method, resulting in incorrect results for leaf samples. To gain a more thorough understanding of the effects of sample type (e. g., leaf, root, stem and soil), sample species, sampling time and climatic condition (dry vs. wet) on water isotope estimates using IRIS, we collected soil samples and plant components from a number of major species at a fine temporal resolution (every 2 h for 24-48 h) across three locations with different climatic conditions in the Heihe River Basin, China. The hydrogen and oxygen isotopic compositions of the extracted water from these samples were measured using both an IRMS and an IRIS instrument. The results show that the mean discrepancies between the IRMS and IRIS approaches for delta O-18 and delta D, respectively, were: -5.6 parts per thousand and -75.7 parts per thousand for leaf water; -4.0 parts per thousand and -23.3 parts per thousand for stem water; -3.4 parts per thousand and -28.2 parts per thousand for root water; -0.5 parts per thousand and -6.7 parts per thousand for xylem water; -0.06 parts per thousand and -0.3 parts per thousand for xylem flow; and -0.1 parts per thousand and 0.3 parts per thousand for soil water. The order of the discrepancy was: leaf > stem approximate to root > xylem > xylem flow approximate to soil. In general, species of the same functional types (e. g., woody vs. herbaceous) within similar habitats showed similar deviations. For different functional types, the differences were large. Sampling at nighttime did not remove the observed deviations. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:3071 / 3082
页数:12
相关论文
共 50 条
  • [1] Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters
    West, Adam G.
    Goldsmith, Gregory R.
    Brooks, Paul D.
    Dawson, Todd E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (14) : 1948 - 1954
  • [2] Comments on "Discrepancies between isotope ratio infrared spectroscopy and isotope ratio mass spectrometry for the stable isotope analysis of plant and soil waters"
    Brand, Willi A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (17) : 2687 - 2688
  • [3] Analytical techniques in biomedical stable isotope applications: (isotope ratio) mass spectrometry or infrared spectrometry?
    Stellaard, F
    Elzinga, H
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2005, 41 (04) : 345 - 361
  • [4] Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates
    Moerdijk-Poortvliet, Tanja C. W.
    Schierbeek, Henk
    Houtekamer, Marco
    van Engeland, Tom
    Derrien, Delphine
    Stal, Lucas J.
    Boschker, Henricus T. S.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (13) : 1205 - 1214
  • [5] Spectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS)
    West, A. G.
    Goldsmith, G. R.
    Matimati, I.
    Dawson, T. E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (16) : 2268 - 2274
  • [6] Isotope ratio mass spectrometry
    Muccio, Zeland
    Jackson, Glen P.
    ANALYST, 2009, 134 (02) : 213 - 222
  • [7] Stable nitrogen isotope analysis of chlorophylls by gas chromatography-isotope ratio mass spectrometry
    Chikaraishi, Y.
    Kashiyama, Y.
    Ogawa, N. O.
    Kitazato, H.
    Nomoto, S.
    Ohkouchi, N.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A100 - A100
  • [8] Stable isotope analysis of fatty acids by gas chromatography-isotope ratio mass spectrometry
    Meier-Augenstein, W
    ANALYTICA CHIMICA ACTA, 2002, 465 (1-2) : 63 - 79
  • [9] Study on distribution pattern of stable carbon isotope ratio of Chinese honeys by isotope ratio mass spectrometry
    Pang, GF
    Fan, CL
    Cao, YZ
    Zhang, JJ
    Li, XM
    Li, ZY
    Jia, GQ
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2006, 86 (02) : 315 - 319
  • [10] Laser ablation isotope ratio mass spectrometry for enhanced sensitivity and spatial resolution in stable isotope analysis
    Moran, James J.
    Newburn, Matt K.
    Alexander, M. Lizabeth
    Sams, Robert L.
    Kelly, James F.
    Kreuzer, Helen W.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (09) : 1282 - 1290