Stereo-Correlation and Noise-Distribution Aware ResVoxGAN for Dense Slices Reconstruction and Noise Reduction in Thick Low-Dose CT

被引:9
|
作者
Ge, Rongjun [1 ,2 ,3 ,5 ,6 ]
Yang, Guanyu [1 ,2 ,3 ]
Xu, Chenchu [5 ,6 ]
Chen, Yang [1 ,2 ,3 ,4 ]
Luo, Limin [1 ,2 ,3 ]
Li, Shuo [5 ,6 ]
机构
[1] Southeast Univ, Lab Image Sci & Technol, Sch Comp Sci & Engn, Nanjing, Jiangsu, Peoples R China
[2] Ctr Rech Informat Biomed Sino Francais LIA CRIBs, Rennes, Ille & Vilaine, France
[3] Southeast Univ, Minist Educ, Key Lab Comp Network & Informat Integrat, Nanjing, Jiangsu, Peoples R China
[4] Southeast Univ, Sch Cyber Sci & Engn, Nanjing, Jiangsu, Peoples R China
[5] Western Univ, Dept Med Imaging & Med Biophys, London, ON, Canada
[6] Digital Imaging Grp London, London, ON, Canada
关键词
D O I
10.1007/978-3-030-32226-7_37
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The low-dose computed tomography (CT) scan with thick slice thickness (3mm) dramatically improves the imaging efficiency and reduces the radiation risk in clinical. However, the low-dose CT acquisition inherently compromises the signal-to-noise ratio, and the sparse sampled thick slices poorly reproduce the coronal/sagittal anatomy. We propose a Residual Voxel Generative Adversarial Nets (ResVoxGAN), the first powerful work to densely reconstruct slices into the thin thickness (1 mm), and simultaneously denoise the CT image into the more readable pattern, directly from the widely accessible thick low-dose CT. The framework is achieved in a voxel-wise conditional GAN constituted by the following: (1) a generator is composed of consecutive 3D multi-scale residual blocks that richly extracts multi-scale stereo feature for fine-granted and latent spatial structure mining from the noisy volume, and a followed Subpixel Convnet further interpretively reconstructs dense slices from the features for high-resolution and denoising volume; (2) a stereo-correlation constraint elegantly penalizes gradient deviation in voxel adjacent region (i.e., 3D 26-neighborhoods) to guide structural detail, together with a image-expression constraint on perceptual feature representations transformed from a pretrained deep convolution autoencoder to keep scene content; and (3) a pair of coupled discriminators advantageously fuse the prior-knowledge from the thick low-dose CT with the generated image and residual noise via self-learning to drive the generation towards into both realistic anatomic structure distribution and valid noise-reduction distribution. The experiment validated on Mayo dataset shows that the ResVoxGAN successfully reconstruct the low-dose CT of 3mm thickness into 1 mm, and meanwhile keeps the with peak signal to noise ratio of 40.80 for noise reduction, and structural similarity index of 0.918 for dense slices reconstruction. These advantages reveal our method a great potential in clinical CT imaging. [GRAPHICS] .
引用
收藏
页码:328 / 338
页数:11
相关论文
共 50 条
  • [41] A comparison study on KL domain penalized weighted least-squares approach to noise reduction for low-dose cone-beam CT
    Zhang, Hao
    Liu, Yan
    Han, Hao
    Fan, Yi
    Wang, Jing
    Liang, Zhengrong
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3328 - 3332
  • [42] Impact of Deep Learning-based Optimization Algorithm on Image Quality of Low-dose Coronary CT Angiography with Noise Reduction: A Prospective Study
    Liu, Peijun
    Wang, Man
    Wang, Yining
    Yu, Min
    Wang, Yun
    Liu, Zhuoheng
    Li, Yumei
    Jin, Zhengyu
    [J]. ACADEMIC RADIOLOGY, 2020, 27 (09) : 1241 - 1248
  • [43] The value of using a deep learning image reconstruction algorithm of thinner slice thickness to balance the image noise and spatial resolution in low-dose abdominal CT
    Wang, Huan
    Li, Xinyu
    Wang, Tianze
    Li, Jianying
    Sun, Tianze
    Chen, Lihong
    Cheng, Yannan
    Jia, Xiaoqian
    Niu, Xinyi
    Guo, Jianxin
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1814 - 1824
  • [44] Noise indices adjusted to body mass index and an iterative reconstruction algorithm maintain image quality on low-dose contrast-enhanced liver CT
    Zhao, Yongxia
    Suo, Hongna
    Wu, Yanmin
    Zuo, Ziwei
    Zhao, Sisi
    Cheng, Shujie
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (04) : 597 - 611
  • [45] Multi-Frame Low-Dose CT Image noise reduction using Adaptive Type-2 Fuzzy filter and Fast-ICA
    Mohebbian, Mohammad Reza
    Hassan, Ahmad M.
    Wahid, Khan A.
    Babyn, Paul
    [J]. 2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 690 - 693
  • [47] Improved dose calculation accuracy for low energy brachytherapy by optimizing dual energy CT imaging protocols for noise reduction using sinogram affirmed iterative reconstruction
    Landry, Guillaume
    Gaudreault, Mathieu
    van Elmpt, Wouter
    Wildberger, Joachim E.
    Verhaegen, Frank
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 75 - 87
  • [48] Realization of reliable cerebral-blood-flow maps from low-dose CT perfusion images by statistical noise reduction using nonlinear diffusion filtering.
    Saito N.
    Kudo K.
    Sasaki T.
    Uesugi M.
    Koshino K.
    Miyamoto M.
    Suzuki S.
    [J]. Radiological Physics and Technology, 2008, 1 (1) : 62 - 74
  • [49] Low-dose, wide-detector array thoracic aortic CT angiography using an iterative reconstruction technique results in improved image quality with lower noise and fewer artifacts
    Rajiah, Prabhakar
    Schoenhagen, Paul
    Mehta, Dhruv
    Ivanc, Thomas
    Lieber, Michael
    Soufan, Kassem
    Desai, Milind
    Flamm, Scott D.
    Halliburton, Sandra
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) : 205 - 213
  • [50] Effect of new non-linear three-dimensional noise reduction filters on image quality and lesion characteristics to improve image quality of low-dose abdominal CT
    Rizzo, SMR
    Kalra, MK
    Blake, MA
    Maher, MM
    Schmidt, B
    Raupach, R
    Saini, SS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 29 - 29