A comparison study on KL domain penalized weighted least-squares approach to noise reduction for low-dose cone-beam CT

被引:0
|
作者
Zhang, Hao [1 ]
Liu, Yan [2 ]
Han, Hao [2 ]
Fan, Yi [2 ]
Wang, Jing [3 ]
Liang, Zhengrong [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol & Biomed Engn, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
关键词
ITERATIVE IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; RAY; LIKELIHOOD;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dose reduction is a major task for cone-beam computed tomography (CBCT) applications because of the potential side effect of X-ray exposure to the patients. One of the strategies to achieve low-dose is to lower the X-ray tube current and/or shorten the exposure time in CT scanners. However, the image quality from the low mAs acquisition is severely degraded due to excessive quantum noise. In this work, we investigated three implementations of Karhunen-Loeve domain penalized weighted least-squares (KL-PWLS) scheme to adaptively treat the noise in the low-mAs CBCT sinograms. The motivation is based on the observations that strong data correlation exists between neighboring views and neighboring slices in CBCT and the KL transform can de-compose the correlated signals for adaptive noise treatment. The three implementations were: (1) performing the KL transform among neighboring views and reduce the three-dimensional (3D) noise-treatment procedure into a series of 2D operations, (2) performing the KL transform among neighboring slices in the 3D space, and (3) performing the KL transform on a view-by-view manner along the slice direction for sparse data sampling which actually reduces the procedure into a series of 1D operations. The noise-treated sinogram data were then reconstructed by the analytical Feldkamp-Davis-Kress (FDK) algorithm. The effectiveness of the presented KL-PWLS noise reduction strategy was evaluated using two physical phantoms (CatPhan600 (R) and anthropomorphic head). Noise in the reconstructed CBCT-FDK images from a low 10mA protocol was greatly suppressed without noticeable sacrifice of the spatial resolution compared with those from a high 80mA protocol, which implies a potential dose reduction by as high as a factor of 8 for the two phantoms. The noise-resolution tradeoff curves indicate that the KL-PWLS implementations considering the neighboring slices (implementation 2 and 3) outperform that considering the neighboring views (implementation 1) in better resolution preservation at the same noise level, which is probably due to the structural continuity among neighboring slices. For further dose reduction by sparse data sampling, implementation (3) can be a potential choice attributed to its computational advantages over the other two implementations.
引用
收藏
页码:3328 / 3332
页数:5
相关论文
共 50 条
  • [1] A comparison study of sinogram- and image-domain penalized re-weighted least-squares approaches to noise reduction for low-dose cone-beam CT
    Zhang, Hao
    Liu, Yan
    Han, Hao
    Wang, Jing
    Ma, Jianhua
    Li, Lihong
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [2] LBP-based penalized weighted least-squares approach to low-dose cone-beam computed tomography reconstruction
    Ma, Ming
    Wang, Huafeng
    Liu, Yan
    Zhang, Hao
    Gu, Xianfeng
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [3] Noise reduction for cone-beam SPECT by penalized reweighted least-squares projection restoration
    Zhang, Hao
    Wen, Junhai
    Shi, Donghao
    Yang, Rui
    Wang, Jing
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [4] Optimize the Smoothing Parameter in Penalized Weighted Least-Squares Algorithm for Noise Reduction of Low-Dose CBCT
    Wang, J.
    Guan, H.
    Solberg, T.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [5] Noise reduction for low-dose helical CT by fully 3D penalized weighted least-squares sinogram smoothing
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [6] Inverse determination of the penalty parameter in penalized weighted least-squares algorithm for noise reduction of low-dose CBCT
    Wang, Jing
    Guan, Huaiqun
    Solberg, Timothy
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 4066 - 4072
  • [7] Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (10) : 1272 - 1283
  • [8] Penalized weighted least-squares approach for low-dose X-ray computed tomography
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    [J]. MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [9] Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCT
    Ouyang, Luo
    Solberg, Timothy
    Wang, Jing
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17): : 5535 - 5552
  • [10] Iterative Raw Measurements Restoration Method with Penalized Weighted Least Squares Approach for Low-Dose CT
    Takahashi, Hisashi
    Goto, Taiga
    Hirokawa, Koichi
    Miyazaki, Osamu
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033