The value of using a deep learning image reconstruction algorithm of thinner slice thickness to balance the image noise and spatial resolution in low-dose abdominal CT

被引:3
|
作者
Wang, Huan [1 ]
Li, Xinyu [2 ]
Wang, Tianze
Li, Jianying [2 ,3 ]
Sun, Tianze [1 ]
Chen, Lihong [1 ]
Cheng, Yannan [1 ]
Jia, Xiaoqian [1 ]
Niu, Xinyi [1 ]
Guo, Jianxin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiol, Xian, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Med, Dept Neurosurg, Xian, Peoples R China
[3] Computed Tomog Res Ctr, GE Healthcare, Beijing, Peoples R China
关键词
Deep learning; image reconstruction; different layer thickness; radiation dose; ITERATIVE RECONSTRUCTION; QUALITY; ANGIOGRAPHY; REDUCTION;
D O I
10.21037/qims-22-353
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Traditional reconstruction techniques have certain limitations in balancing image quality and reducing radiation dose. The deep learning image reconstruction (DLIR) algorithm opens the door to a new era of medical image reconstruction. The purpose of the study was to evaluate the DLIR images at 1.25 mm thickness in balancing image noise and spatial resolution in low-dose abdominal computed tomography (CT) in comparison with the conventional adaptive statistical iterative reconstruction-V at 40% strength (ASIR-V40%) at 5 and 1.25 mm. Methods: This retrospective study included 89 patients who underwent low-dose abdominal CT. Five sets of images were generated using ASIR-V40% at a 5 mm slice thickness and 1.25 mm (high-resolution) with DLIR at 1.25 mm using 3 strengths: low (DLIR-L), medium (DLIR-M), and high (DLIR-H). Qualitative evaluation was performed for image noise, artifacts, and visualization of small structures, while quantitative evaluation was performed for standard deviation (SD), signal-to-noise ratio (SNR), and spatial resolution (defined as the edge rising slope). Results: At 1.25 mm, DLIR-M and DLIR-H images had significantly lower noise (SD in fat: 14.29 +/- 3.37 and 9.65 +/- 3.44 HU, respectively), higher SNR for liver (3.70 +/- 0.78 and 5.64 +/- 1.20, respectively), and higher overall image quality (4.30 +/- 0.44 and 4.67 +/- 0.40, respectively) than did the respective values in ASIR-V40% images (20.60 +/- 4.04 HU, 2.60 +/- 0.63, and 3.77 +/- 0.43; all P values <0.05). Compared with the 5 mm ASIR-V40% images, the 1.25 mm DLIR-H images had lower noise (SD: 9.65 +/- 3.44 vs. 13.63 +/- 10.03 HU), higher SNR (5.64 +/- 1.20 vs. 4.69 +/- 1.28), and higher overall image quality scores (4.67 +/- 0.40 vs. 3.94 +/- 0.46) (all P values <0.001). In addition, DLIR-L, DLIR-M, and DLIR-H images had a significantly higher spatial resolution in terms of edge rising slope (59.66 +/- 21.46, 58.52 +/- 17.48, and 59.26 +/- 13.33, respectively, vs. 33.79 +/- 9.23) and significantly higher image quality scores in the visualization of fine structures (4.43 +/- 0.50, 4.41 +/- 0.49, and 4.38 +/- 0.49, respectively vs. 2.62 +/- 0.49) than did the 5 mm ASIR-V40 images. Conclusions: The 1.25 mm DLIR-M and DLIR-H images had significantly reduced image noise and improved SNR and overall image quality compared to the 1.25 mm ASIR-V40% images, and theyhad significantly improved the spatial resolution , visualization of fine structures compared to the 5 mm ASIR-V40% images. DLIR-H images had further reduced image noise compared with the 5 mm ASIR-V40% images , DLIR-H was the most effective technique at balancing the image noise and spatial resolution in low-dose abdominal CT.
引用
收藏
页码:1814 / 1824
页数:11
相关论文
共 50 条
  • [1] A feasibility study of realizing low-dose abdominal CT using deep learning image reconstruction algorithm
    Li, Lu-Lu
    Wang, Huang
    Song, Jian
    Shang, Jin
    Zhao, Xiao-Ying
    Liu, Bin
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (02) : 361 - 372
  • [2] Improving spatial resolution and diagnostic confidence with thinner slice and deep learning image reconstruction in contrast-enhanced abdominal CT
    Le Cao
    Xiang Liu
    Tingting Qu
    Yannan Cheng
    Jianying Li
    Yanan Li
    Lihong Chen
    Xinyi Niu
    Qian Tian
    Jianxin Guo
    [J]. European Radiology, 2023, 33 : 1603 - 1611
  • [3] Improving spatial resolution and diagnostic confidence with thinner slice and deep learning image reconstruction in contrast-enhanced abdominal CT
    Cao, Le
    Liu, Xiang
    Qu, Tingting
    Cheng, Yannan
    Li, Jianying
    Li, Yanan
    Chen, Lihong
    Niu, Xinyi
    Tian, Qian
    Guo, Jianxin
    [J]. EUROPEAN RADIOLOGY, 2023, 33 (03) : 1603 - 1611
  • [4] Low-Dose CT Image Reconstruction With a Deep Learning Prior
    Park, Hyoung Suk
    Kim, Kyungsang
    Jeon, Kiwan
    [J]. IEEE ACCESS, 2020, 8 : 158647 - 158655
  • [5] Image Quality Improvement of Low-dose Abdominal CT using Deep Learning Image Reconstruction Compared with the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Lee, Jeong Min
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    [J]. CURRENT MEDICAL IMAGING, 2024, 20
  • [6] Image Quality Improvement of Low-dose Abdominal CT Using Deep Learning Image Reconstruction Compared With the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Min Lee, Jeong
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    [J]. Current Medical Imaging, 2024, 20
  • [7] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393
  • [8] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Damiano Caruso
    Domenico De Santis
    Antonella Del Gaudio
    Gisella Guido
    Marta Zerunian
    Michela Polici
    Daniela Valanzuolo
    Dominga Pugliese
    Raffaello Persechino
    Antonio Cremona
    Luca Barbato
    Andrea Caloisi
    Elsa Iannicelli
    Andrea Laghi
    [J]. European Radiology, 2024, 34 : 2384 - 2393
  • [9] Image quality improvement in low-dose chest CT with deep learning image reconstruction
    Tian, Qian
    Li, Xinyu
    Li, Jianying
    Cheng, Yannan
    Niu, Xinyi
    Zhu, Shumeng
    Xu, Wenting
    Guo, Jianxin
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [10] Diagnostic performance and image quality of deep learning image reconstruction (DLIR) on unenhanced low-dose abdominal CT for urolithiasis
    Delabie, Aurelien
    Bouzerar, Roger
    Pichois, Raphael
    Desdoit, Xavier
    Vial, Jeremie
    Renard, Cedric
    [J]. ACTA RADIOLOGICA, 2022, 63 (09) : 1283 - 1292