Diagnostic performance and image quality of deep learning image reconstruction (DLIR) on unenhanced low-dose abdominal CT for urolithiasis

被引:9
|
作者
Delabie, Aurelien [1 ]
Bouzerar, Roger [2 ]
Pichois, Raphael [1 ]
Desdoit, Xavier [1 ]
Vial, Jeremie [1 ]
Renard, Cedric [1 ]
机构
[1] Amiens Univ Hosp, Dept Radiol, 1 Rond Point Prof Christian Cabrol, F-80054 Amiens 01, France
[2] Amiens Univ Hosp, Med Image Proc Unit, Amiens, France
关键词
Urolithiasis; computed tomography; image enhancement; deep learning; image reconstruction; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; CANCER-RISKS; RADIATION; REDUCTION; TOMOGRAPHY; IMPACT; CHEST;
D O I
10.1177/02841851211035896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Patients with urolithiasis undergo radiation overexposure from computed tomography (CT) scans. Improvement of image reconstruction is necessary for radiation dose reduction. Purpose To evaluate a deep learning-based reconstruction algorithm for CT (DLIR) in the detection of urolithiasis at low-dose non-enhanced abdominopelvic CT. Material and Methods A total of 75 patients who underwent low-dose abdominopelvic CT for urolithiasis were retrospectively included. Each examination included three reconstructions: DLIR; filtered back projection (FBP); and hybrid iterative reconstruction (IR; ASiR-V 70%). Image quality was subjectively and objectively assessed using attenuation and noise measurements in order to calculate the signal-to-noise ratio (SNR), absolute contrast, and contrast-to-noise ratio (CNR). Attenuation of the largest stones were also compared. Detectability of urinary stones was assessed by two observers. Results Image noise was significantly reduced with DLIR: 7.2 versus 17 and 22 for ASiR-V 70% and FBP, respectively. Similarly, SNR and CNR were also higher compared to the standard reconstructions. When the structures had close attenuation values, contrast was lower with DLIR compared to ASiR-V. Attenuation of stones was also lowered in the DLIR series. Subjective image quality was significantly higher with DLIR. The detectability of all stones and stones >3 mm was excellent with DLIR for the two observers (intraclass correlation [ICC] = 0.93 vs. 0.96 and 0.95 vs. 0.99). For smaller stones (<3 mm), results were different (ICC = 0.77 vs. 0.86). Conclusion For low-dose abdominopelvic CT, DLIR reconstruction exhibited image quality superior to ASiR-V and FBP as well as an excellent detection of urinary stones.
引用
收藏
页码:1283 / 1292
页数:10
相关论文
共 50 条
  • [1] Unenhanced abdominal low-dose CT reconstructed with deep learning-based image reconstruction: image quality and anatomical structure depiction
    Kaga, Tetsuro
    Noda, Yoshifumi
    Mori, Takayuki
    Kawai, Nobuyuki
    Miyoshi, Toshiharu
    Hyodo, Fuminori
    Kato, Hiroki
    Matsuo, Masayuki
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (07) : 703 - 711
  • [2] Unenhanced abdominal low-dose CT reconstructed with deep learning-based image reconstruction: image quality and anatomical structure depiction
    Tetsuro Kaga
    Yoshifumi Noda
    Takayuki Mori
    Nobuyuki Kawai
    Toshiharu Miyoshi
    Fuminori Hyodo
    Hiroki Kato
    Masayuki Matsuo
    [J]. Japanese Journal of Radiology, 2022, 40 : 703 - 711
  • [3] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Damiano Caruso
    Domenico De Santis
    Antonella Del Gaudio
    Gisella Guido
    Marta Zerunian
    Michela Polici
    Daniela Valanzuolo
    Dominga Pugliese
    Raffaello Persechino
    Antonio Cremona
    Luca Barbato
    Andrea Caloisi
    Elsa Iannicelli
    Andrea Laghi
    [J]. European Radiology, 2024, 34 : 2384 - 2393
  • [4] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393
  • [5] Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
    Lee, Dong Ho
    Lee, Jeong Min
    Lee, Chang Hee
    Afat, Saif
    Othman, Ahmed
    [J]. RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2024, 6 (02)
  • [6] Image quality improvement in low-dose chest CT with deep learning image reconstruction
    Tian, Qian
    Li, Xinyu
    Li, Jianying
    Cheng, Yannan
    Niu, Xinyi
    Zhu, Shumeng
    Xu, Wenting
    Guo, Jianxin
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [7] Image Quality Improvement of Low-dose Abdominal CT using Deep Learning Image Reconstruction Compared with the Second Generation Iterative Reconstruction
    Kang, Hyo-Jin
    Lee, Jeong Min
    Park, Sae Jin
    Lee, Sang Min
    Joo, Ijin
    Yoon, Jeong Hee
    [J]. CURRENT MEDICAL IMAGING, 2024, 20
  • [8] Low-Dose CT Image Reconstruction With a Deep Learning Prior
    Park, Hyoung Suk
    Kim, Kyungsang
    Jeon, Kiwan
    [J]. IEEE ACCESS, 2020, 8 : 158647 - 158655
  • [9] Deep learning image reconstruction algorithms in low-dose radiation abdominal computed tomography: assessment of image quality and lesion diagnostic confidence
    Yang, Chun
    Wang, Wenzhe
    Cui, Dingye
    Zhang, Jinliang
    Liu, Ling
    Wang, Yuxin
    Li, Wei
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (05) : 3161 - 3173
  • [10] The Value of Deep Learning Image Reconstruction in Improving the Quality of Low-Dose Chest CT Images
    Jiang, Jiu-Ming
    Miao, Lei
    Liang, Xin
    Liu, Zhuo-Heng
    Zhang, Li
    Li, Meng
    [J]. DIAGNOSTICS, 2022, 12 (10)