Diagnostic performance and image quality of deep learning image reconstruction (DLIR) on unenhanced low-dose abdominal CT for urolithiasis

被引:9
|
作者
Delabie, Aurelien [1 ]
Bouzerar, Roger [2 ]
Pichois, Raphael [1 ]
Desdoit, Xavier [1 ]
Vial, Jeremie [1 ]
Renard, Cedric [1 ]
机构
[1] Amiens Univ Hosp, Dept Radiol, 1 Rond Point Prof Christian Cabrol, F-80054 Amiens 01, France
[2] Amiens Univ Hosp, Med Image Proc Unit, Amiens, France
关键词
Urolithiasis; computed tomography; image enhancement; deep learning; image reconstruction; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; CANCER-RISKS; RADIATION; REDUCTION; TOMOGRAPHY; IMPACT; CHEST;
D O I
10.1177/02841851211035896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Patients with urolithiasis undergo radiation overexposure from computed tomography (CT) scans. Improvement of image reconstruction is necessary for radiation dose reduction. Purpose To evaluate a deep learning-based reconstruction algorithm for CT (DLIR) in the detection of urolithiasis at low-dose non-enhanced abdominopelvic CT. Material and Methods A total of 75 patients who underwent low-dose abdominopelvic CT for urolithiasis were retrospectively included. Each examination included three reconstructions: DLIR; filtered back projection (FBP); and hybrid iterative reconstruction (IR; ASiR-V 70%). Image quality was subjectively and objectively assessed using attenuation and noise measurements in order to calculate the signal-to-noise ratio (SNR), absolute contrast, and contrast-to-noise ratio (CNR). Attenuation of the largest stones were also compared. Detectability of urinary stones was assessed by two observers. Results Image noise was significantly reduced with DLIR: 7.2 versus 17 and 22 for ASiR-V 70% and FBP, respectively. Similarly, SNR and CNR were also higher compared to the standard reconstructions. When the structures had close attenuation values, contrast was lower with DLIR compared to ASiR-V. Attenuation of stones was also lowered in the DLIR series. Subjective image quality was significantly higher with DLIR. The detectability of all stones and stones >3 mm was excellent with DLIR for the two observers (intraclass correlation [ICC] = 0.93 vs. 0.96 and 0.95 vs. 0.99). For smaller stones (<3 mm), results were different (ICC = 0.77 vs. 0.86). Conclusion For low-dose abdominopelvic CT, DLIR reconstruction exhibited image quality superior to ASiR-V and FBP as well as an excellent detection of urinary stones.
引用
收藏
页码:1283 / 1292
页数:10
相关论文
共 50 条
  • [21] Deep learning reconstruction allows low-dose imaging while maintaining image quality: comparison of deep learning reconstruction and hybrid iterative reconstruction in contrast-enhanced abdominal CT
    Tamura, Akio
    Mukaida, Eisuke
    Ota, Yoshitaka
    Nakamura, Iku
    Arakita, Kazumasa
    Yoshioka, Kunihiro
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (05) : 2977 - 2984
  • [22] Deep Learning with Adaptive Hyper-Parameters for Image Reconstruction in Low-Dose CT
    Ding, Q.
    Gao, H.
    Ji, H.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E392 - E392
  • [23] Deep Learning With Adaptive Hyper-Parameters for Low-Dose CT Image Reconstruction
    Ding, Qiaoqiao
    Nan, Yuesong
    Gao, Hao
    Ji, Hui
    [J]. IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2021, 7 : 648 - 660
  • [24] A dataset-free deep learning method for low-dose CT image reconstruction
    Ding, Qiaoqiao
    Ji, Hui
    Quan, Yuhui
    Zhang, Xiaoqun
    [J]. INVERSE PROBLEMS, 2022, 38 (10)
  • [25] Image quality guided iterative reconstruction for low-dose CT based on CT image statistics
    Duan, Jiayu
    Mou, Xuanqin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [26] Assessment of deep learning image reconstruction (DLIR) on image quality in pediatric cardiac CT datasets type of manuscript: Original research
    Cho, Hyun-Hae
    Lee, So Mi
    You, Sun Kyoung
    [J]. PLOS ONE, 2024, 19 (08):
  • [27] Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT
    Jingyu Zhong
    Hailin Shen
    Yong Chen
    Yihan Xia
    Xiaomeng Shi
    Wei Lu
    Jianying Li
    Yue Xing
    Yangfan Hu
    Xiang Ge
    Defang Ding
    Zhenming Jiang
    Weiwu Yao
    [J]. Journal of Digital Imaging, 2023, 36 : 1390 - 1407
  • [28] Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT
    Zhong, Jingyu
    Shen, Hailin
    Chen, Yong
    Xia, Yihan
    Shi, Xiaomeng
    Lu, Wei
    Li, Jianying
    Xing, Yue
    Hu, Yangfan
    Ge, Xiang
    Ding, Defang
    Jiang, Zhenming
    Yao, Weiwu
    [J]. JOURNAL OF DIGITAL IMAGING, 2023, 36 (04) : 1390 - 1407
  • [29] Application of a deep learning image reconstruction (DLIR) algorithm in head CT imaging for children to improve image quality and lesion detection
    Sun, Jihang
    Li, Haoyan
    Wang, Bei
    Li, Jianying
    Li, Michelle
    Zhou, Zuofu
    Peng, Yun
    [J]. BMC MEDICAL IMAGING, 2021, 21 (01)
  • [30] DIAGNOSTIC PERFORMANCE OF LOW-DOSE NON ENHANCE CT WITH ITERATIVE RECONSTRUCTION IN DIAGNOSIS OF UROLITHIASIS
    Choe, Jung Won
    Do Kim, Kyung
    Moon, Young Tae
    Kwon, Jong Kyou
    Chang, In Ho
    Kim, Jung Noon
    Choi, Jae Duck
    Ahn, Seung Hyun
    Kim, Min Su
    Lee, So Yeon
    Ryu, Jae Hyung
    Park, Sang Ho
    [J]. JOURNAL OF UROLOGY, 2014, 191 (04): : E902 - E902