Diagnostic performance and image quality of deep learning image reconstruction (DLIR) on unenhanced low-dose abdominal CT for urolithiasis

被引:9
|
作者
Delabie, Aurelien [1 ]
Bouzerar, Roger [2 ]
Pichois, Raphael [1 ]
Desdoit, Xavier [1 ]
Vial, Jeremie [1 ]
Renard, Cedric [1 ]
机构
[1] Amiens Univ Hosp, Dept Radiol, 1 Rond Point Prof Christian Cabrol, F-80054 Amiens 01, France
[2] Amiens Univ Hosp, Med Image Proc Unit, Amiens, France
关键词
Urolithiasis; computed tomography; image enhancement; deep learning; image reconstruction; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; CANCER-RISKS; RADIATION; REDUCTION; TOMOGRAPHY; IMPACT; CHEST;
D O I
10.1177/02841851211035896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Patients with urolithiasis undergo radiation overexposure from computed tomography (CT) scans. Improvement of image reconstruction is necessary for radiation dose reduction. Purpose To evaluate a deep learning-based reconstruction algorithm for CT (DLIR) in the detection of urolithiasis at low-dose non-enhanced abdominopelvic CT. Material and Methods A total of 75 patients who underwent low-dose abdominopelvic CT for urolithiasis were retrospectively included. Each examination included three reconstructions: DLIR; filtered back projection (FBP); and hybrid iterative reconstruction (IR; ASiR-V 70%). Image quality was subjectively and objectively assessed using attenuation and noise measurements in order to calculate the signal-to-noise ratio (SNR), absolute contrast, and contrast-to-noise ratio (CNR). Attenuation of the largest stones were also compared. Detectability of urinary stones was assessed by two observers. Results Image noise was significantly reduced with DLIR: 7.2 versus 17 and 22 for ASiR-V 70% and FBP, respectively. Similarly, SNR and CNR were also higher compared to the standard reconstructions. When the structures had close attenuation values, contrast was lower with DLIR compared to ASiR-V. Attenuation of stones was also lowered in the DLIR series. Subjective image quality was significantly higher with DLIR. The detectability of all stones and stones >3 mm was excellent with DLIR for the two observers (intraclass correlation [ICC] = 0.93 vs. 0.96 and 0.95 vs. 0.99). For smaller stones (<3 mm), results were different (ICC = 0.77 vs. 0.86). Conclusion For low-dose abdominopelvic CT, DLIR reconstruction exhibited image quality superior to ASiR-V and FBP as well as an excellent detection of urinary stones.
引用
收藏
页码:1283 / 1292
页数:10
相关论文
共 50 条
  • [41] Unbiased statistical image reconstruction in low-dose CT
    Hayes, John
    Zhang, Ran
    Zhang, Chengzhu
    Gomez-Cardona, Daniel
    Chen, Guang-Hong
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [42] Iterative reconstruction vs deep learning image reconstruction: comparison of image quality and diagnostic accuracy of arterial stenosis in low--dose lower extremity CT angiography
    Qu, Tingting
    Guo, Yinxia
    Li, Jianying
    Cao, Le
    Li, Yanan
    Chen, Lihong
    Sun, Jingtao
    Lu, Xueni
    Guo, Jianxin
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1140):
  • [43] Low-Dose CT Examinations in Crohn's Disease: Impact on Image Quality, Diagnostic Performance, and Radiation Dose
    Kambadakone, Avinash R.
    Prakash, Priyanka
    Hahn, Peter F.
    Sahani, Dushyant V.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) : 78 - 88
  • [44] Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window
    Jinhua Wang
    Xin Sui
    Ruijie Zhao
    Huayang Du
    Jiaru Wang
    Yun Wang
    Ruiyao Qin
    Xiaoping Lu
    Zhuangfei Ma
    Yinghao Xu
    Zhengyu Jin
    Lan Song
    Wei Song
    [J]. European Radiology, 2024, 34 : 1053 - 1064
  • [45] Deep learning-based reconstruction improves the image quality of low-dose CT enterography in patients with inflammatory bowel disease
    He, Weitao
    Xu, Ping
    Zhang, Mengchen
    Xu, Rulin
    Shen, Xiaodi
    Mao, Ren
    Li, Xue-hua
    Sun, Can-hui
    Zhang, Ruo-nan
    Lin, Shaochun
    [J]. ABDOMINAL RADIOLOGY, 2024,
  • [46] Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window
    Wang, Jinhua
    Sui, Xin
    Zhao, Ruijie
    Du, Huayang
    Wang, Jiaru
    Wang, Yun
    Qin, Ruiyao
    Lu, Xiaoping
    Ma, Zhuangfei
    Xu, Yinghao
    Jin, Zhengyu
    Song, Lan
    Song, Wei
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (02) : 1053 - 1064
  • [47] Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial Experience
    Jensen, Corey T.
    Liu, Xinming
    Tamm, Eric P.
    Chandler, Adam G.
    Sun, Jia
    Morani, Ajaykumar C.
    Javadi, Sanaz
    Wagner-Bartak, Nicolaus A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (01) : 50 - 57
  • [48] Sinogram-based deep learning image reconstruction technique in abdominal CT: image quality considerations
    Parakh, Anushri
    Cao, Jinjin
    Pierce, Theodore T.
    Blake, Michael A.
    Savage, Cristy A.
    Kambadakone, Avinash R.
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (11) : 8342 - 8353
  • [49] Sinogram-based deep learning image reconstruction technique in abdominal CT: image quality considerations
    Anushri Parakh
    Jinjin Cao
    Theodore T. Pierce
    Michael A. Blake
    Cristy A. Savage
    Avinash R. Kambadakone
    [J]. European Radiology, 2021, 31 : 8342 - 8353
  • [50] Image Quality Assessment of Low-Dose CT using Hybrid Iterative Reconstruction
    Zhang, Qiao
    Sheng, Jinhua
    Chen, Bin
    [J]. JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2021, 65 (06)