The value of using a deep learning image reconstruction algorithm of thinner slice thickness to balance the image noise and spatial resolution in low-dose abdominal CT

被引:3
|
作者
Wang, Huan [1 ]
Li, Xinyu [2 ]
Wang, Tianze
Li, Jianying [2 ,3 ]
Sun, Tianze [1 ]
Chen, Lihong [1 ]
Cheng, Yannan [1 ]
Jia, Xiaoqian [1 ]
Niu, Xinyi [1 ]
Guo, Jianxin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiol, Xian, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Med, Dept Neurosurg, Xian, Peoples R China
[3] Computed Tomog Res Ctr, GE Healthcare, Beijing, Peoples R China
关键词
Deep learning; image reconstruction; different layer thickness; radiation dose; ITERATIVE RECONSTRUCTION; QUALITY; ANGIOGRAPHY; REDUCTION;
D O I
10.21037/qims-22-353
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Traditional reconstruction techniques have certain limitations in balancing image quality and reducing radiation dose. The deep learning image reconstruction (DLIR) algorithm opens the door to a new era of medical image reconstruction. The purpose of the study was to evaluate the DLIR images at 1.25 mm thickness in balancing image noise and spatial resolution in low-dose abdominal computed tomography (CT) in comparison with the conventional adaptive statistical iterative reconstruction-V at 40% strength (ASIR-V40%) at 5 and 1.25 mm. Methods: This retrospective study included 89 patients who underwent low-dose abdominal CT. Five sets of images were generated using ASIR-V40% at a 5 mm slice thickness and 1.25 mm (high-resolution) with DLIR at 1.25 mm using 3 strengths: low (DLIR-L), medium (DLIR-M), and high (DLIR-H). Qualitative evaluation was performed for image noise, artifacts, and visualization of small structures, while quantitative evaluation was performed for standard deviation (SD), signal-to-noise ratio (SNR), and spatial resolution (defined as the edge rising slope). Results: At 1.25 mm, DLIR-M and DLIR-H images had significantly lower noise (SD in fat: 14.29 +/- 3.37 and 9.65 +/- 3.44 HU, respectively), higher SNR for liver (3.70 +/- 0.78 and 5.64 +/- 1.20, respectively), and higher overall image quality (4.30 +/- 0.44 and 4.67 +/- 0.40, respectively) than did the respective values in ASIR-V40% images (20.60 +/- 4.04 HU, 2.60 +/- 0.63, and 3.77 +/- 0.43; all P values <0.05). Compared with the 5 mm ASIR-V40% images, the 1.25 mm DLIR-H images had lower noise (SD: 9.65 +/- 3.44 vs. 13.63 +/- 10.03 HU), higher SNR (5.64 +/- 1.20 vs. 4.69 +/- 1.28), and higher overall image quality scores (4.67 +/- 0.40 vs. 3.94 +/- 0.46) (all P values <0.001). In addition, DLIR-L, DLIR-M, and DLIR-H images had a significantly higher spatial resolution in terms of edge rising slope (59.66 +/- 21.46, 58.52 +/- 17.48, and 59.26 +/- 13.33, respectively, vs. 33.79 +/- 9.23) and significantly higher image quality scores in the visualization of fine structures (4.43 +/- 0.50, 4.41 +/- 0.49, and 4.38 +/- 0.49, respectively vs. 2.62 +/- 0.49) than did the 5 mm ASIR-V40 images. Conclusions: The 1.25 mm DLIR-M and DLIR-H images had significantly reduced image noise and improved SNR and overall image quality compared to the 1.25 mm ASIR-V40% images, and theyhad significantly improved the spatial resolution , visualization of fine structures compared to the 5 mm ASIR-V40% images. DLIR-H images had further reduced image noise compared with the 5 mm ASIR-V40% images , DLIR-H was the most effective technique at balancing the image noise and spatial resolution in low-dose abdominal CT.
引用
收藏
页码:1814 / 1824
页数:11
相关论文
共 50 条
  • [31] Investigation of Low-Dose CT Image Denoising Using Unpaired Deep Learning Methods
    Li, Zeheng
    Zhou, Shiwei
    Huang, Junzhou
    Yu, Lifeng
    Jin, Mingwu
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (02) : 224 - 234
  • [32] Research progress of deep learning in low-dose CT image denoising
    Zhang, Fan
    Liu, Jingyu
    Liu, Ying
    Zhang, Xinhong
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (04) : 337 - 346
  • [33] LOW DOSE ABDOMINAL CT IMAGE RECONSTRUCTION: AN UNSUPERVISED LEARNING BASED APPROACH
    Kuanar, Shiba
    Athitsos, Vassilis
    Mahapatra, Dwarikanath
    Rao, K. R.
    Akhtar, Zahid
    Dasgupta, Dipankar
    2019 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2019, : 1351 - 1355
  • [34] Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window
    Jinhua Wang
    Xin Sui
    Ruijie Zhao
    Huayang Du
    Jiaru Wang
    Yun Wang
    Ruiyao Qin
    Xiaoping Lu
    Zhuangfei Ma
    Yinghao Xu
    Zhengyu Jin
    Lan Song
    Wei Song
    European Radiology, 2024, 34 : 1053 - 1064
  • [35] Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window
    Wang, Jinhua
    Sui, Xin
    Zhao, Ruijie
    Du, Huayang
    Wang, Jiaru
    Wang, Yun
    Qin, Ruiyao
    Lu, Xiaoping
    Ma, Zhuangfei
    Xu, Yinghao
    Jin, Zhengyu
    Song, Lan
    Song, Wei
    EUROPEAN RADIOLOGY, 2024, 34 (02) : 1053 - 1064
  • [36] Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise
    Kim, Joo Hee
    Yoon, Hyun Jung
    Lee, Eunju
    Kim, Injoong
    Cha, Yoon Ki
    Bak, So Hyeon
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (01) : 131 - 138
  • [37] Deep learning reconstruction allows low-dose imaging while maintaining image quality: comparison of deep learning reconstruction and hybrid iterative reconstruction in contrast-enhanced abdominal CT
    Tamura, Akio
    Mukaida, Eisuke
    Ota, Yoshitaka
    Nakamura, Iku
    Arakita, Kazumasa
    Yoshioka, Kunihiro
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (05) : 2977 - 2984
  • [38] Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
    Lee, Dong Ho
    Lee, Jeong Min
    Lee, Chang Hee
    Afat, Saif
    Othman, Ahmed
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2024, 6 (02)
  • [39] Impact of deep learning image reconstruction on volumetric accuracy and image quality of pulmonary nodules with different morphologies in low-dose CT
    D'hondt, L.
    Franck, C.
    Kellens, P-j.
    Zanca, F.
    Buytaert, D.
    Van Hoyweghen, A.
    El Addouli, H.
    Carpentier, K.
    Niekel, M.
    Spinhoven, M.
    Bacher, K.
    Snoeckx, A.
    CANCER IMAGING, 2024, 24 (01)
  • [40] Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study
    Joël Greffier
    Quentin Durand
    Julien Frandon
    Salim Si-Mohamed
    Maeliss Loisy
    Fabien de Oliveira
    Jean-Paul Beregi
    Djamel Dabli
    European Radiology, 2023, 33 : 699 - 710